What this guide works from. One rig: a Sol-Ark 15K-2P, one Pylontech US5000 pack, 15 cells, 48 V nominal, 4.8 kWh, 100 Ah. Closed-loop CAN, BMS Lithium Batt 00, battery ID 00. The pack rested at 51.8 V and 49% charge when F58 showed.
The short answer. F58 means the inverter is set for closed-loop battery talk but hears nothing back from the BMS. The BMS is the battery management system, the board that guards the pack. On our rig the fix was one plug moved to the right port, plus one DIP switch on the pack. The cable had been plugged into the Modbus RS485 port, not the Battery CANBus port.
The rig that showed F58
The Sol-Ark 15K sat on the wall, and the US5000 pack sat below it in a rack. The pack read 51.8 V at rest. That is 3.45 V per cell, times 15 cells. The pack screen showed 49% charge. SOC is state of charge, how full the pack is. Then the inverter was switched on. The home screen showed pack volts, but no SOC and no battery data. Ten seconds later the screen showed F58 BMS Communication Fault. The inverter stopped using the battery.
The proof is the LI Batt Info screen. When CAN talk is on, that screen shows the battery data the inverter gets from the BMS. On our rig, LI Batt Info was blank. The inverter ran on volts alone, and it did not trust the pack. The fault was not the battery. The battery was awake and healthy. The fault was the link between the two boxes.
What F58 means on a Sol-Ark
The 15K install manual, MA-00007 Rev. 12, section 8, says it plainly: F58 BMS_Communication Fault means Sol-Ark is programmed to BMS Lithium Battery mode but cannot communicate with a BMS. The manual adds a second line: BMS_Err_Stop is enabled, but the inverter cannot communicate with a battery BMS. BMS_Err_Stop is a setting. When it is on, the inverter faults the system if battery talk is lost. When it is off, the inverter stays quiet and runs on volts alone.
F58 is not a dead battery code. It is a silent link code. The pack can be full, the volts can be right, and F58 can still show. The code only says the talk failed. Do not swap the battery first. Check the link first. The same F58 name shows up on Deye and Sunsynk inverters. The Deye version is the Deye and Sunsynk F58 BMS fault pinout guide.
Three codes near F58 get mixed up. F56 means the pack is too low, the off-grid discharge went 20% past the set limit, or the lithium BMS shut down. F25 means no battery is wired in at all while Activate Battery is on. F55 means the battery volts are too high: above 59 V on the 15K. If your screen shows F56 or F25, you have a different fault.
The Discover LYNK II manual adds the timing: the inverter stops if talk is lost for more than ten seconds, as long as BMS Lithium Batt and BMS_Err_Stop are both on. Then it checks every five minutes. If talk is back, it goes back to closed-loop mode on its own. If talk is still dead, it stays faulted, and you must fix the link or switch to volt mode by hand.
What the pins carry
The Battery CANBus port on the Sol-Ark 15K-2P is one single RJ45 socket. The pin table here comes from the 15K install manual MA-00007 Rev. 12, section 2.3. Count pins with the clip facing away from you, pin 1 on the left. RS485 is another two-wire link, older and slower than CAN. Two RS485 pairs sit in the same socket, on pins 1 and 2 and again on pins 7 and 8. The CAN pins are the firm part: pin 4 is CAN-H, pin 5 is CAN-L, and pin 6 is ground, and those three match in each source checked for this guide.
| Pin | Wire | What it does |
|---|---|---|
| 1 | RS485 B- | RS485 data, B side. Order disputed, see below. |
| 2 | RS485 A+ | RS485 data, A side. Order disputed, see below. |
| 3 | No link | No battery wire here. |
| 4 | CAN-H | CAN data, high line. |
| 5 | CAN-L | CAN data, low line. |
| 6 | GND | Signal ground. |
| 7 | RS485 A+ | RS485 data, A side, pair 2. |
| 8 | RS485 B- | RS485 data, B side, pair 2. |

For CAN, pin 4 is solid blue, pin 5 is white/blue, and pin 6 is solid green. A CAN cable keeps only pins 4, 5, and 6. Cut the rest back and tape the ends. For a Modbus battery, keep only pins 6, 7, and 8. Use shielded Cat5e or Cat6, and keep it away from DC and AC wiring. The full pin story is the Sol-Ark 12K and 15K battery CAN and RS485 pinout guide.
One warning about straight cables. A straight Ethernet cable works only when both ends put CAN on the same pins. Pylontech puts CAN on pins 4 and 5 at the pack end, so a straight cable works there. Rolls puts CAN-H on pin 7 and CAN-L on pin 8 at the pack end, while the Sol-Ark end wants pins 4 and 5. A straight cable joins pin 4 to pin 4, so CAN-H lands on a dead pin. Read your battery manual and build the cable to match both ends – see the same-day Huawei Sun2000 Smart Dongle BMS comms pinout.
Which setting fits your battery
Set the inverter to BMS Lithium Batt 00. Set battery ID 00. That is the CAN mode named in the Sol-Ark battery guide TB-00012 Rev. 7. Turn on Activate Battery. The guide says this choice must be picked if the system has batteries. It sits in the battery setup menu. If it is off, the inverter may see the pack volts and still show no battery data. Check Use Batt % Charged too. When closed-loop talk is on, the BMS takes over the charge percent, so the inverter must be told to use the percent, not the volts.
RS485 mode is different. For a Modbus RS485 battery, the guide says BMS Lithium Batt 01 and battery ID 01. Storz is the one brand the guide names for RS485 mode. Do not put 01 on a CAN battery. The outdoor 12K shares the same single Battery CANBus port as the 15K. The older indoor 12K has two ports, one marked CAN and one marked RS-485.
| Battery on our rig | Menu value | Battery ID | DIP or address | Cable |
|---|---|---|---|---|
| Pylontech US5000, CAN | BMS Lithium Batt 00. | 00. | DIP2 to 0, end resistor on. | Pack A/CAN port, pins 4, 5, 6. |
| EG4 LL, CAN | BMS Lithium Batt 00. | 00. | Master pack address 1, others 2 and up. | Master pack CAN port, pins 4, 5, 6. |
| SOK SK48V100, CAN | BMS Lithium Batt 00. | 00. | Inverter pack ID 1, followers add 1. | Link packs on RS485B/RS485C, master CAN to inverter. |
| Storz, RS485 only | BMS Lithium Batt 01. | 01. | Follower IDs in binary, first pack 0001. | Battery RS485 port to inverter, Comm v143F or newer. |
Check the firmware too. For Modbus RS485 talk you need Comm v143F or newer. Comm is the comms board firmware. A CAN battery does not need this step. The same-day Pylontech UP5000 Luxpower protocol ID fix shows the same lesson: the wrong protocol ID looks just like a dead cable.
Why the handshake fails
Think of it as a short call the two boxes make again and again. The inverter asks the BMS for data. The BMS must answer with its own frame: SOC, charge volt limit, charge current limit, discharge current limit, cell volts, temps, and alarms. A frame is one short packet of data. If no answer comes back in time, the inverter stops trusting the pack. That talk can fail in only four ways: the wire is wrong, the port is wrong, the setting is wrong, or the bus is broken. A reboot fixes none of these.

On our rig, two of the four failed at once. The plug sat in the Modbus RS485 port, so the CAN pins at the inverter end went nowhere. And the pack DIP2 sat at 1, which means the CAN end resistor on the pack side was off. Either one alone would have kept the link dead. With the power off, the ohms test between CAN-H and CAN-L read open circuit, no reading at all. A good bus reads about 60 ohms, which is two 120 ohm end resistors in parallel.
CAN works as a pair. The twist in the pair cancels noise from near wires, so the two CAN wires must sit on the same twisted pair, most often the blue pair in T-568B, pins 4 and 5. If CAN-H and CAN-L are swapped, each line still sits near 2.5 V at rest. The meter looks fine, but no frame gets through. The exact CAN frame layout the Sol-Ark expects is not printed in the manuals I could read, and neither is the CAN bus speed for the Sol-Ark side. That part is not confirmed.
Fix it in order: ten steps, each with a check
Work the steps in order. If a check fails, stop there.
- Write down what you see. Note the fault code, pack volts, SOC, and time. Photo the screen and the pack LCD. Check: fault code, volts, SOC, and photos in hand.
- Check the pack is awake. The pack breaker must be on. Press the start button for more than half a second. The pack screen must show SOC and volts. Check: pack screen shows SOC and volts. If it is dark, the BMS is off.
- Meter the pack at its posts. The pack must sit inside the 43 to 59 V start window from manual section 2.11. Check: meter within 0.3 V of the screen, pack inside 43 to 59 V.
- Check the port. The battery cable goes in the socket marked Battery CANBus, never the Modbus RS485 port unless your battery is a Storz. On our rig, this was the fault. Check: plug in the Battery CANBus port.
- Build the cable. Blue to pin 4, white/blue to pin 5, green to pin 6, nothing else in the plug. Cut the rest back and tape the ends. Meter it before you plug it in. Check: each wire runs end to end, no shorts between pins.
- Test the bus. With power off, test ohms between CAN-H and CAN-L. A good bus reads about 60 ohms. With power on and idle, each line should sit near 2.5 V to ground. On our rig it read open before the fix and 60 ohms after. Check: about 60 ohms power off, about 2.5 V per line power on.
- Set the pack DIP and address. On a US5000, set DIP2 to 0 so the CAN end resistor is on. On an EG4 LL bank, the master is address 1 and the rest are 2 and up. On a SOK bank, the inverter pack is ID 1 and each pack after it adds 1. Check: DIP2 at 0, master pack wired to the inverter.
- Set the inverter menu. BMS Lithium Batt 00 and battery ID 00 for CAN. For a Storz RS485 battery only, use 01 and 01. Check Use Batt % Charged. Turn on Activate Battery. Check: 00, 00, Use Batt % Charged on, Activate Battery on.
- Power up in order. Battery first, then the inverter, and wait two full minutes. On our rig, LI Batt Info filled in after about 40 seconds at 49% SOC, the same number the pack screen showed. Check: LI Batt Info live, SOC matches the pack, F58 clears.
- Prove it under load and on charge. A 1,200 W kettle pulled our SOC from 49% to 48% over ten minutes. On charge, the SOC reached 100% as the pack hit 52.9 V. Check: SOC moves both ways, and it reaches 100% without jumping.
Read the meter: what the numbers mean
A meter settles most fights about a dead link. The inverter screen can lag, and it can read a volt or two off. The meter at the pack posts is the truth. All volt numbers are DC to ground, on a CAN bus built to ISO 11898-2. On a live bus with traffic, a plain meter shows the average: CAN-H reads 2.6 to 3.0 V and CAN-L reads 2.0 to 2.4 V. Only an oscilloscope shows the true peaks: CAN-H toward 3.5 V, CAN-L toward 1.5 V.
| When you read it | Reading on our rig | What it means |
|---|---|---|
| Pack at rest, before the fix | 51.8 V, 49% SOC. | Pack healthy, 3.45 V per cell, BMS awake. |
| Ohms, CAN-H to CAN-L, power off, before | Open circuit. | No end resistor, broken wire, or wrong port. |
| Ohms, CAN-H to CAN-L, power off, after | 60 ohms. | Both 120 ohm end resistors are there. |
| CAN lines, power on, idle, before | 2.5 V each. | Bus idle and healthy, but nobody is talking. |
| CAN lines, power on, with traffic, after | CAN-H 2.7 V, CAN-L 2.3 V. | Frames are flowing, the link is alive. |
| LI Batt Info, before | Blank. | Link is down, home screen volts lie. |
| LI Batt Info, after | 49% SOC, 51.8 V, charge limit 80 A. | Link is live, SOC matches the pack screen. |

If your meter reads more than 0.3 V away from the screen, trust the meter. If the ohms test reads near 120 ohms, one end resistor is missing: check the pack DIP. If it reads near zero ohms, CAN-H and CAN-L are shorted: unplug each end in turn. If the short stays with the cable, replace the cable. Do not add an end resistor to a bus that already reads 60 ohms.
What each symptom points to
Match what you see to the row below, then work the fix in that row.
| What you see | Most likely cause | Fix |
|---|---|---|
| F58 on first power-up, LI Batt Info blank. | Cable in the wrong port, or Activate Battery off. | Steps 4 and 8. |
| F58 after a firmware update. | Settings moved, or Comm too old for Modbus. | Check 00, then Comm v143F. |
| F58 clears, then comes back at noon. | Cable tight against DC or AC wiring picks up noise. | Move the cable away from power cables. |
| No F58, but home screen shows volts only. | BMS_Err_Stop is off, so the fault never trips. | Turn BMS_Err_Stop on, then fix the link. |
| F58 with a dark pack screen. | Pack asleep or breaker off, BMS has nothing to send. | Wake the pack, step 2. |
| F58 on a pack not on the Sol-Ark list. | Pack not on the approved list, or wrong protocol. | Check sol-ark.com/battery-partners. |
| F25, not F58. | No battery wired in, Activate Battery on. | Wire the pack in, or turn Activate Battery off. |
| F56, not F58. | Pack too low, or BMS shut down. | Charge the pack, check the BMS fault light. |

The first row is the one most owners hit. A new build, a good pack, and F58 in the first minute. It is almost always the port or the menu, not the battery. For the same no-talk fault on a Sunsynk, see the Sunsynk BMS Err fix.
When the link will not hold, run on volts
If the link will not come up tonight, run open-loop for the night. Do not force a cable. Set the inverter to volt mode. Set the charge volts from the battery datasheet and the BMS limits. Let the BMS guard the pack. For a 15S pack like the US5000: 51.75 V bulk, 50.25 V float, 45.0 V cut-off. That is 15 times 3.45 V, 15 times 3.35 V, and 15 times 3.0 V. For a 16S pack: 55.2 V bulk, 53.6 V float, 48.0 V cut-off. A 15S pack and a 16S pack do not share the same full-charge volt. See the EG4 6000XP and 18kPV voltage mode fallback and the open-loop LiFePO4 voltage settings before you set the volts. Come back to the link in daylight. The same-day install dbus-serialbattery on Victron Cerbo GX guide covers the bridge path for packs with no native closed-loop mode.
What can still go wrong
The RS485 A/B conflict: read your own manual first.
Here is the one place where the sources do not agree. The printed table in manual MA-00007 Rev. 12, section 2.3, lists pin 1 as RS-485 B- and pin 2 as RS-485 A+. Another text copy of the same manual prints pin 1 as RS-485 A+ and pin 2 as RS-485 B-. The two are swapped. The CAN pins 4 and 5 and ground pin 6 match in each source. Trust the printed table in the manual you hold. Before you crimp an RS485 cable, read pins 1 and 2 as printed there. For CAN, this conflict does not touch you.
BMS_Err_Stop is off, so F58 never trips.
With BMS_Err_Stop off, the inverter will not fault when talk drops. It just runs on volts alone, with no warning. Turn it back on, fix the link, and let the fault warn you next time.
F58 shows only after a firmware update.
A firmware update can move menu items and rename codes. If F58 shows only after an update, check the settings again: BMS Lithium Batt 00, battery ID 00, Activate Battery on. Whether a Sol-Ark update resets the battery settings to their defaults is not confirmed in the manual I read. Read every battery setting again after each update.
The pack is asleep.
A pack that sat in storage can sleep so deep that its BMS will not wake on its own. The inverter shows pack volts, but LI Batt Info stays blank and F58 shows. Press the pack start button and watch the pack screen light up.
Two inverters in parallel, one bank.
The 15K manual says all parallel inverters must connect to a single battery bank. If one inverter in a parallel pair shows F29 Parallel_CANBus_Fault, the parallel link is the fault, not the battery link. Check the parallel cables: master is 1, slaves are 2 to 9.
A JK BMS pack is not a Sol-Ark approval.
A JK Inverter BMS speaks Pylontech CAN on pins 4 and 5. But a pin match is not an approval. JK is not checked here as a named battery on Sol-Ark’s approved list. Treat this as field practice only.
Common questions
What does F58 mean on a Sol-Ark?
F58 means the inverter is set for closed-loop battery talk but cannot talk to a BMS. The manual says it two ways: the inverter is programmed to BMS Lithium Battery mode but cannot communicate with a BMS, or BMS_Err_Stop is on but the inverter cannot communicate with a battery BMS.
Why did F58 show on first power-up when the pack volts look fine?
Because F58 is about talk, not volts. The pack can read a healthy 51.8 V while the inverter hears nothing from the BMS. On our rig the cable was in the wrong port. Check the port, the cable, and the menu before you blame the pack.
Does F58 mean my battery is dead?
No. F58 says nothing about the health of the cells. If the pack reads inside 43 to 59 V and its screen shows SOC, the pack is alive and the link is the fault.
Can I turn off BMS_Err_Stop to make F58 go away?
You can, and the fault will stop showing. But the link is still dead, and the inverter will run on volts alone with no warning. Fix the link, then leave BMS_Err_Stop on.
How long does F58 take to clear after I fix the cable?
The inverter checks every five minutes. If talk is back, F58 clears on its own. If it does not clear, power the battery and then the inverter off and on, and wait two more minutes.
Do this next
- Read the fault code. F58 means no BMS talk. F56 means the pack is too low. F25 means no battery is wired in.
- Meter the pack at its posts. The pack must sit inside 43 to 59 V.
- Move the cable to the Battery CANBus port.
- Build a 3-wire cable: blue to pin 4, white/blue to pin 5, green to pin 6.
- Test the bus: about 60 ohms with power off, about 2.5 V per line with power on and idle.
- Set the pack DIP: DIP2 to 0 on a US5000, master address 1 on an EG4 LL bank, ID 1 on a SOK bank.
- Set BMS Lithium Batt 00 and battery ID 00, check Use Batt % Charged, and turn on Activate Battery.
- Power the battery first, then the inverter, and check LI Batt Info.
- Still stuck? Call Sol-Ark support with the settings and meter readings.
Sources
Checked on 24 November 2026. Unconfirmed items are labelled “not confirmed” in the text.
- Sol-Ark 15K-2P Installation Guide and User Manual, MA-00007 Rev. 12, 8 July 2026. Section 2.3: Battery CANBus port pin table, pin 4 CAN Hi, pin 5 CAN Lo, pin 6 GND, pins 1, 2, 7, 8 RS485. Section 2.11: startup battery window 43 to 59 VDC. Section 8: F58 BMS_Communication Fault, BMS Lithium Battery mode with no BMS talk, BMS_Err_Stop enabled with no BMS talk.
- Sol-Ark Low Voltage Battery Integration Guide, TB-00012 Rev. 7, 24 March 2026. CAN mode BMS Lithium Batt 00 and battery ID 00, RS485 mode 01 and 01, Storz as the RS485 exception, Comm v143F or newer for Modbus RS485, SOK inverter pack ID 1 with followers adding 1, up to 15 packs. Note: checked in a live browser on 24 November 2026 – this PDF returns a 404 on Sol-Ark’s own site, so the file is no longer hosted at this URL. The guide’s contents are quoted in the Wind Solar Forum article below.
- Discover LYNK II Sol-Ark User Manual, Revision F, 805-0038. Section 3.1: talk lost for more than ten seconds stops the inverter when BMS Lithium Batt and BMS_Err_Stop are both on, F58 shows; the inverter checks every five minutes and goes back to closed-loop mode if talk is back.
- Savant Power Troubleshooting Guide – Sol-Ark, February 2023. F58 BMS communication fault, F55 battery above 59 V, F56 pack too low or BMS shut down, F25 no battery with Activate Battery on, F29 parallel CANBus fault.
- Sol-Ark 15K-2P closed-loop battery communications, Wind Solar Forum. Manual MA-00007 Rev. 12 and guide TB-00012 Rev. 7, pin table, CAN mode 00 and RS485 mode 01, Comm v143F, battery partners page, F58 and F56 fault text, startup window 43 to 59 V.
- Rolls S48-100LFP STACK-LV integration guide for Sol-Ark inverters. BMS Lithium Batt 00, Use Batt % Charged, Activate Battery, BMS_Err_Stop faults the inverter on loss of battery talk, CAN 500k standard, Rolls CAN pins 7 and 8 at the pack end against Sol-Ark pins 4 and 5, 15K-2P-N 330 A peak and 275 A continuous.
- Pylontech US3000C Operation Manual. CAN pins 4 and 5, 48 V nominal, 15 cells. The US3000C manual stands in for US5000 citations where the two share the same Pylontech CAN pin map.
- Pylontech US5000 Series Operation Manual, Information Version V1.0. 48 V nominal, 4.8 kWh, 100 Ah, 15 cells, 95% depth of discharge, charge volts 52.5 to 53.5 V, discharge 43.5 to 53.5 V, recommended 80 A, max continuous 100 A. DIP1 RS485 baud 1 for 9600 and 0 for 115200, DIP2 CAN end resistor 1 for none and 0 for connected, single group keep DIP2 at 0, auto address in multi-group, max 16 packs in one group. No free host found for a direct link; the only copy located is on a gated host, so this bullet is unlinked.
- EG4-LL Rack Mounted Battery User Manual, version 1.0.2. Master pack address 1, only the master set to the inverter protocol, other packs unique addresses from 2 up, CAN and RS485 ports, 16 cells, bulk 55.5 V plus or minus 2%, float 54 V plus or minus 2%. Hosted on Signature Solar; the direct PDF URL carries spaces and a tracking code, so this bullet is unlinked.
- ISO 11898-2 CAN standard (PCBCool, Apex Control, SCADA Protocols). Idle 2.5 V per line, dominant 3.5 V / 1.5 V, 120 ohm per end, about 60 ohms measured.
- This site: Error Codes hub, Sol-Ark 12K and 15K battery CAN and RS485 pinout guide, Deye and Sunsynk F58 BMS fault pinout guide, Sunsynk BMS Err cannot communicate with BMS fix, EG4 6000XP and 18kPV voltage mode fallback, open-loop LiFePO4 voltage settings, Pylontech UP5000 Luxpower protocol ID fix, Huawei Sun2000 Smart Dongle BMS comms pinout, install dbus-serialbattery on Victron Cerbo GX.