What this guide works from. One rig: a Victron Cerbo GX, a MultiPlus-II 48/5000, and a JK BMS (JK-B2A24S20P) guarding 16 EVE 280 Ah cells, 14.3 kWh in all. Venus OS 3.6x and driver v2.0.x run on the Cerbo. The pack sat at rest at 52.8 V and 61%. The top cell read 3.34 V and the low cell read 3.29 V.
The short answer. Wire an isolated USB adapter from the BMS to the Cerbo, log in over SSH as root, run the install script from the driver project, and pick the latest release. Then edit config.ini for your pack, restart the driver, and turn on DVCC. On our rig the Cerbo saw no battery at all before the install. After it, the battery showed at 61%, 52.8 V, with a 50 A charge limit and a 60 A discharge limit.
The rig Venus could not see
Sixteen cells in a row, each 3.2 V in name, give 51.2 V. 16S means 16 cells in a row. 280 Ah times 51.2 V gives 14,336 Wh, or 14.3 kWh. The JK BMS guarded the pack: it watched the cell volts, the current and the heat, and it could cut the pack off if a cell went out of range.
But the Cerbo GX could not see any of it. The Cerbo is the small screen box that runs a Victron rig, and Venus OS is the code that runs on it. It showed volts from the MultiPlus, but no charge level, no cell volts and no limits. The MultiPlus charged by volts only. That is open-loop. The full open-loop fallback is in the Open-Loop and Bridges hub.
The JK BMS has a serial port, but the Cerbo has no built-in code to read a JK. The fix is a small driver that runs on the Cerbo and reads the BMS for it. If you want the full story of what the driver is and how it reads a Daly pack, see Can dbus-serialbattery Connect Any Smart BMS to Victron?.
What you need before you start
You need an isolated USB to RS485 adapter for a JK on RS485, or an isolated USB to UART adapter for a BMS on UART. Isolated means the data side has no link to the power side. The driver docs warn that a plain adapter can break your Cerbo and your BMS. If the BMS cuts the minus pole, the full pack current can try to flow down the data cable. Do not skip it. The docs name two tested adapters from Duppa.
You need a laptop with an SSH client: PuTTY on Windows, the plain terminal on a Mac or Linux box. You need the Cerbo on your home net. You need a meter. You need a USB stick in FAT32 form if you plan to use the USB install path instead of SSH. The stick carries venus-data.tar.gz and your config.ini if you made one first.
Check your Venus OS version first. Open Settings, then General, and read the firmware line. The driver you want is v2.0.x. It fits Venus OS v3.5x and v3.6x best. It also runs on v2.9x through v3.4x. But the new GUIv2 screens do not show the driver pages there. Read the driver changelog on GitHub first. It is where a break with a new Venus OS version is first named.
| Venus OS version | Driver version | Driver runs | New GUIv2 screens | Old GUIv1 screens |
|---|---|---|---|---|
| v2.9x | v2.0.x | Yes | No | Yes |
| v3.0x to v3.4x | v2.0.x | Yes | No | Yes |
| v3.5x | v2.0.x | Yes | Yes | Yes |
| v3.6x | v2.0.x | Yes | Yes | Yes |
If your Cerbo is still on an old release, update Venus OS first, then install the driver.
Which BMS boards the driver fits
The driver tries each known BMS type in turn until one answers. You do not type a speed or a port type in config.ini for a normal install. The driver works the type out on its own. Three boards make up most installs. JK is first at 68%. JBD is next at 13%. Daly is third at 12%.
| BMS board | Share of driver rigs | Port to use | What to set in config.ini |
|---|---|---|---|
| JK BMS | 68%, most used | RS485 or UART | Type JKBMS, capacity your Ah |
| JBD BMS | 13% | UART or RS485 | Type JBD, capacity your Ah |
| Daly BMS | 12% | UART or RS485 | Type Daly, sleep time 65535 first |
| Seplos BMS | Small share | RS485, Modbus | Type Seplos, v3 uses Modbus |
| PACE BMS | Small share | RS485 | Type PACE, capacity your Ah |
In config.ini the type line is BMS_TYPE and the size line is BATTERY_CAPACITY. Three boards are switched off by default: ANT since v1.0.0, Sinowealth since v0.14.0, and MNB. The first two caused faults with other boards. MNB needs extra files put in by hand. The install page tells you how to switch each one on. If your BMS is not on the list at all, the driver will try each type and fail on all of them. A BMS with no serial port cannot work with this driver.
If your pack is a Pylontech UP5000 on a Luxpower, the fix is a protocol ID setting, not this driver. See Pylontech UP5000 Luxpower protocol ID fix. And if your rig is a Huawei with a smart dongle and no Cerbo at all, the pinout is a different job. See Huawei Sun2000 smart dongle BMS COM pinout.
Do you need Venus OS Large?
No. This driver runs on the normal Venus OS image. Venus OS Large is the same Venus OS with two extra apps on top: Node-RED and Signal K server. Neither one has anything to do with this driver. You can switch to Large later if you want Node-RED rules. Go to Settings, then General, then Firmware, then Online updates, then Image type, and pick Large.
Why Venus needs a driver at all
Venus OS does not read a BMS serial link on its own. It reads its own message bus, the dbus. The dbus is a set of named slots inside Venus OS. Each slot holds one value, like the pack volts or the charge level. The charger and the screen read those slots.
The driver is the go-between. It asks the BMS for a frame of data, checks that the frame arrived whole, pulls out the numbers, and writes each one into the right dbus slot every few seconds. It also writes four slots that steer the rig: max charge current, max discharge current, max charge volts, and low volts. DVCC, Distributed Voltage and Current Control, reads those slots and tells the chargers what to do. On our rig that capped the charge current at 50 A.
The install lays the driver down in one place: /data/apps/dbus-serialbattery. Venus OS keeps the /data folder when it updates, but it wipes the rest of the system files, so the driver files often stay put. The installer also sets up a service, a small job the box starts on its own each time it boots. That is why a reboot is part of the install.
The driver finds your BMS by trying each known type in turn. For each type it runs a short test. If the test passes, it sticks with that type and polls it every few seconds. If no type answers, it keeps trying. That is why a dead wire looks the same as a wrong BMS type on the screen: no battery at all.
Install it in order: ten steps, each with a check
Work the steps in order. If a check fails, stop there. The SSH path is the main path here. The USB stick path is covered in the questions at the end.

- Meter the pack and write down the numbers. Put the meter on the main lugs and read the pack volts. Open the JK app and read the charge level and the cell volts. Check: pack 52.8 V, charge level 61%, top cell 3.34 V, low cell 3.29 V, spread 0.05 V.
- Check the Venus OS version and read the changelog. Open Settings, then General, and read the firmware line. Read the top lines of the driver changelog on GitHub. Check: Venus OS reads v3.5x or v3.6x, and the changelog lists no break for it.
- Set the root password on the Cerbo. Open Settings, then General. Set the Access Level to User and installer, password ZZZ. Hold the right button on the center pad until the Access Level changes to Superuser. On a touch screen, drag the menu down and hold it for five seconds. Then go to Set root password and make a strong password. Check: the Cerbo asks for the new password twice and takes it.
- Wire the isolated adapter and plug it into the Cerbo. On RS485, wire A to A, B to B, and GND to GND. On UART, cross the pair: TX to RX, and RX to TX. The JK port labels are wrong on some boards, so check the pinout drawing in the driver docs first. Check: the adapter light is on, and the Cerbo lists a new serial port, most often ttyUSB0.
- Run the SSH installer and pick the latest release. Log in as root to the Cerbo address. Run
wget -O /tmp/install.sh https://raw.githubusercontent.com/mr-manuel/venus-os_dbus-serialbattery/master/dbus-serialbattery/install.shand thenbash /tmp/install.sh. A menu shows six picks. Pick 1 for the latest release. The other picks are beta, nightly, branch, one version, and local tar. Check: the script prints that the driver files are in place. If wget fails, check the net cable and the DNS, then run it again. - Reboot the Cerbo and wait one minute. Type
rebootin the SSH window, or go to Settings, then General, then Reboot. Give the box a full minute. Check: the Cerbo screen shows a battery tile that was not there before. - Open the device list and read the battery page. Go to Settings, then Device List, and tap the new battery row. Check: the page reads 61%, 52.8 V, 6.4 A, and 338 W, with the top cell at 3.34 V and the low cell at 3.29 V.
- Edit config.ini for your pack. Open the file with
nano /data/apps/dbus-serialbattery/config.ini. Put [DEFAULT] on the first line. Set BMS_TYPE to JKBMS, BATTERY_CAPACITY to 280, volt limits to 2.900 low and 3.450 high, and float cell volts to 3.375. Save with Ctrl and O, then leave with Ctrl and X. Check: BMS_TYPE reads JKBMS and BATTERY_CAPACITY reads 280. - Restart the driver and re-check the numbers. Run
/data/apps/dbus-serialbattery/restart.sh. Wait 30 seconds, then open the battery page again. Check: the battery still reads 61% and 52.8 V, and the charge limit reads 50 A with the discharge limit at 60 A. - Turn DVCC on and pick the serial battery. Go to Settings, then System Setup, then Charge Control. Turn DVCC on and pick the serial battery as the controlling BMS. Check: DVCC shows On, and the MultiPlus holds its charge under 50 A on a sunny spell.
At 61% the pack holds 170.8 Ah. It still needs 109.2 Ah to fill. At 50 A that takes about 2.2 hours, before the taper slows it down. The power at the start was 338 W: 52.8 V times 6.4 A.
The config.ini settings that matter
The driver ships with safe defaults for lithium iron phosphate cells. LFP is short for lithium iron phosphate, the cell type in our pack. The defaults fit a 16S pack. The file with every stock value is config.default.ini in the same folder. Set the hard limits in your BMS first. Then set the driver limits a bit softer, so the BMS never has to step in.
| Setting | Value on our rig | Why it matters |
|---|---|---|
| BMS_TYPE | JKBMS | Locks the BMS type in place |
| BATTERY_CAPACITY | 280 Ah | Must match the cells |
| MAX_BATTERY_CHARGE_CURRENT | 50.0 A | Driver default, the CCL |
| MAX_BATTERY_DISCHARGE_CURRENT | 60.0 A | Driver default, the DCL |
| MIN_CELL_VOLTAGE | 2.900 V | 16 times 2.9 V is 46.4 V |
| MAX_CELL_VOLTAGE | 3.450 V | 16 times 3.45 V is 55.2 V |
| FLOAT_CELL_VOLTAGE | 3.375 V | 16 times 3.375 V is 54.0 V |

16 cells times 3.45 V is 55.2 V. 16 cells times 2.9 V is 46.4 V. 16 cells times 3.375 V is 54.0 V. Our pack read 52.8 V at rest, as it should at 61%.
All settings live in config.ini, at /data/apps/dbus-serialbattery/config.ini. You can also edit the file on your PC and copy it over with SFTP. If you do that, check the line ends: if they change from LF to CRLF, the driver can fail with a strange error. After any edit, run restart.sh. If you change a Bluetooth or CAN setting, reboot instead.
What each screen should show after a good install
Start at the top. The main screen of the Cerbo shows a battery tile with the charge level in big type. On our rig it read 61%. Tap the tile and you get the battery page: pack volts 52.8 V, current 6.4 A, power 338 W, top cell 3.34 V, low cell 3.29 V, spread 0.05 V.

Open Settings, then Device List, and tap the battery row. You see the same numbers, plus the limits: max charge volts 55.2 V, max charge current 50 A, and max discharge current 60 A. Open Settings, then System Setup, then Charge Control. DVCC reads On with the serial battery picked as the controlling BMS. The exact words on the battery row are not confirmed in the docs, so look for a new battery row, not for one set name.
Now run one full charge. The current should hold near 50 A while the pack is low, then taper as the volts near 55.2 V. At the top the pack should rest at 54.0 V float, and the cell spread should stay under 0.10 V.
What each symptom points to
Match what you see to the row below. Change one thing at a time.
| What you see. | Most likely cause. | Fix. |
|---|---|---|
| No battery tile after install and reboot. | Wire fault, wrong port, or no driver. | Check the adapter light, then steps 4 and 5. |
| Charge level stuck at one number. | BATTERY_CAPACITY is wrong. | Step 8: set it to 280 Ah on our rig. |
| Charge limit reads 0 A. | A cell is past its volt limit, or DVCC is off. | Check cell volts, then step 10. |
| Cerbo shows the battery, but the charger ignores it. | DVCC is off, or the wrong battery is picked. | Step 10: DVCC on, serial battery picked. |
A meter can rule out a dead link in minutes. If the phone app reads 61% and the Cerbo reads nothing, the fault sits in the wire or the driver, not in the pack. An F58 on a Sol-Ark is a different fault with its own fix. See Sol-Ark 12k 15k F58 BMS communication fault fix.
What can still go wrong
The driver is gone after a Venus OS update.
This is the top trap with any third-party driver. Venus OS keeps the /data folder across updates, so the driver files often stay in place. But often is not always: when Victron moved to the new GUIv2 screens, some installs broke. Read the changelog before you update, then re-run the installer. Then check the battery tile: if the battery is gone, the driver did not load.

The root password is gone after a firmware update.
The root password lives on the system files, not in /data. A firmware update wipes the system files, so the password is reset. That is true from Venus OS v2.00 on. After an update, set the root password again with the same steps as step 3. If Superuser will not stick, go back one page and try the hold again.
The driver picks the wrong BMS type.
The driver tries each type in turn and sticks with the first one that answers. It can pick the wrong one. The signs are odd numbers: volts that read right but a charge level that never moves. Set BMS_TYPE in config.ini to your board, as in step 8, and restart the driver. That locks the type in place.
Two packs on one Cerbo GX.
One driver install can read more than one pack, but Venus OS still only lets one battery steer the rig, so you pick one pack as the controlling BMS. If the picked pack hits 100% first, the rig goes to float while the second pack is still at 90%. For JK inverter BMS packs, give each pack its own address with the jumpers on the front, and list them as BATTERY_ADDRESSES = 0x01, 0x02. Do not use address 0x00: that sets the BMS to master mode and kills the RS485 link. For a bridge that joins packs into one CAN battery, see YamBMS ESP32 bridge for Victron and Deye.
A cheap USB adapter that will not hold a link.
The docs name two tested isolated adapters. A cheap unbranded stick may work on day one and drop the link on day ten, or fail to show up as ttyUSB0 at all. Whether any one cheap chip works on Venus OS is not confirmed in the docs, so do not bet a live rig on it. If the link drops and the wire is sound, swap in a tested isolated adapter before you blame the driver. Bluetooth is not stable on some rigs, so use a cable. A charge limit that drops to 0 A is most often a volt limit or DVCC, not the adapter. See Pylontech Victron Venus OS charge current limit 0A.
Common questions
Do I need Venus OS Large to install dbus-serialbattery?
No. The driver runs on the normal Venus OS image. Large adds Node-RED and Signal K, and neither one is used by this driver.
Can I install it from a USB stick instead of SSH?
Yes. Fetch venus-data.tar.gz from the driver releases page on GitHub. Copy it to the root of a USB stick in FAT32 form. If you made a config.ini first, put that in the root of the stick too. Plug the stick into the Cerbo and reboot. The box installs it on its own. Then reboot once more. The docs warn that this path might not work on older Cerbo GX boxes.
How do I update the driver to a new release?
Read the changelog first. Then run the installer again over SSH, the same two lines as step 5, and pick 1 for the latest release. Or copy the new venus-data.tar.gz to a FAT32 stick and reboot. Reboot the Cerbo after the update, then check the battery tile and the limits. If the tile is gone, pick a known good release with menu pick 5.
How do I remove the driver for good?
Log in over SSH and run bash /data/apps/dbus-serialbattery/uninstall.sh. If you only want it off for now, run bash /data/apps/dbus-serialbattery/disable.sh instead, and turn it back on later with bash /data/apps/dbus-serialbattery/enable.sh. After a disable or a removal, set your solar chargers back to stand-alone mode, or they will throw a BMS lost fault.
Will Victron help me if the driver breaks my rig?
No. This is third-party code, not a Victron product. Victron does not back it. If you open a case with Victron, they will ask you to take the driver off first and show that the fault stays gone. Keep the uninstall command in your notes.
Can I run two packs on one Cerbo?
Yes, and the driver can read both, but Venus OS still only lets one battery steer the rig. If the two packs drift apart in charge level, the rig will float early and leave the second pack short. A battery aggregator joins them into one virtual battery that Venus OS can steer as one. If the link will not hold at all, run open-loop for the night. For open-loop charge levels you can trust, see Victron SmartShunt in open-loop for accurate SOC.
Do this next
- Meter the pack at rest and write down volts, charge level, and cell volts.
- Check the Venus OS version and read the driver changelog.
- Set the root password on the Cerbo, and keep it in a safe place.
- Wire the isolated adapter, TX to RX and RX to TX on UART, or A to A and B to B on RS485.
- Run the SSH installer, pick 1 for the latest release, and reboot.
- Check the battery tile, then the device list, then the battery page.
- Edit config.ini for your pack size and limits, then run restart.sh.
- Turn DVCC on, pick the serial battery, and check the charge limit.
- Run one full charge, watch the taper to 54.0 V float, and check the spread.
- If the link will not hold, run open-loop for the night. Browse the Open-Loop and Bridges hub.
Sources
Checked on 24 November 2026. Unconfirmed items are labelled “not confirmed” in the text.
- dbus-serialbattery, GitHub README, mr-manuel/venus-os_dbus-serialbattery. Driver for Venus OS GX devices and Raspberry Pi. Serial RS232, RS485 and TTL UART plus Bluetooth. First put out by Louis van der Walt in September 2020, kept up by mr-manuel since early 2023. Publishes to the dbus and acts as battery monitor.
- How to install, update, disable, enable and uninstall, dbus-serialbattery docs. Venus OS v3.5x and v3.6x with driver v2.0.x, GUIv2 works. Defaults: charge 50 A, discharge 60 A, min cell 2.9 V, max cell 3.45 V, float cell 3.375 V. USB stick install with venus-data.tar.gz, SSH install script, menu picks 1 to 6. DVCC under Settings, System Setup, Charge Control. Disable, enable and uninstall scripts.
- Supported BMS, dbus-serialbattery docs. Most used: JKBMS 68%, JBD 13%, Daly 12%. Seplos 16E tested, v3 uses Modbus. ANT, Sinowealth and MNB switched off by default. Packs from 3 to 32 cells.
- How to connect and prepare the battery/BMS, dbus-serialbattery docs. Isolated adapter warning, TX to RX cross, RS485 A, B and GND daisy chain, 120 to 130 ohm end resistor past 10 metres. JK port labels wrong on some boards. Daly sleep time 65535 in BmsMonitor, board numbers set in BmsMonitor not the app, BATTERY_ADDRESSES 0x40, 0x41, 0x42. CAN pins GND 3, CAN-H 7, CAN-L 8.
- dbus-serialbattery releases, GitHub. Release files, venus-data.tar.gz, and the changelog to read before an install or an update.
- Venus OS: Root Access, Victron Energy. Set Access Level to User and installer with password ZZZ, hold the right button for Superuser, then Settings, General, Set root password. Root password resets after a firmware update. The /data folder stays put across updates, the system files are wiped.
- Venus OS Large image: Signal K and Node-RED, Victron Energy. Large is the normal Venus OS plus Node-RED and Signal K server. Switch under Settings, General, Firmware, Online updates, Image type. No official support for the Large extras.
- Dbus-serialbattery upgrade stability, Victron Community. Driver broke on some Venus OS updates, most of all at the GUIv2 change. Users report about 30 seconds to find the pack after a reboot. Cerbo still runs if the driver fails, but DVCC has no battery data. Third-party mods are not backed by Victron.
- This site: Open-Loop and Bridges hub, Can dbus-serialbattery Connect Any Smart BMS to Victron?, YamBMS ESP32 bridge for Victron and Deye, Victron SmartShunt in open-loop for accurate SOC, Pylontech Victron Venus OS charge current limit 0A, Pylontech UP5000 Luxpower protocol ID fix, Huawei Sun2000 smart dongle BMS COM pinout, Sol-Ark 12k 15k F58 BMS communication fault fix.
Comments (0)