Closed-Loop vs. Open-Loop Tuning ✓ BENCH VERIFIED UPDATED NOVEMBER 21, 2026 15 MIN READ 3,170 WORDS

Can a Victron SmartShunt Give You True SOC in Open-Loop Mode?

Farhan Ahamed
Farhan Ahamed Published November 19, 2026 · 15 min read
0 COMMENTS
Can a Victron SmartShunt Give You True SOC in Open-Loop Mode?
IN THIS GUIDE · QUICK JUMP KEY SECTIONS
01 · KEY SECTION Jump ↓

The rig that showed two SOC numbers

It was a working build with a lying screen. The Growatt SPF 5000 ES…

02 · KEY SECTION Jump ↓

Why volts SOC fails on LiFePO4

LiFePO4 has a flat discharge curve. That is the whole snag. On a 12…

03 · KEY SECTION Jump ↓

How the shunt counts

A shunt is a small block that counts the amps going in and out.…

04 · KEY SECTION Jump ↓

Wiring: one negative path, no bypass

The shunt sits in the negative cable, right at the battery. Only the battery…

05 · KEY SECTION Jump ↓

Settings that make the count honest

Set the battery size to the bank’s rated amp-hours. Then set the charged volts…

06 · KEY SECTION Jump ↓

The 48 V worked example, with the trap

Say absorption is 55.2 V. Charged volts is 0.2 to 0.3 V under absorption,…

07 · KEY SECTION Jump ↓

If it jumps to 100% too soon

The shunt can jump to 100% while the pack is still far from full,…

08 · KEY SECTION Jump ↓

Set it up in order: nine steps, each with a check

Work the steps in order. If a check fails, stop there.

09 · KEY SECTION Jump ↓

Sync, drift, and the weekly full charge

SOC drifts if the pack never gets a full charge. The pack swings from…

10 · KEY SECTION Jump ↓

If the reading differs, the reading is the answer

Work down the list in order. The table below splits the fault by what…

11 · KEY SECTION Jump ↓

Which shunt, and what about a GX device

The SmartShunt comes in 500 A, 1000 A, and 2000 A types, plus an…

12 · KEY SECTION Jump ↓

SmartShunt and Solar Assistant

Lots of open-loop users pair the shunt with Solar Assistant, a small box that…

What this guide works from. One rig: a Growatt SPF 5000 ES in user-defined mode, a 16-cell LiFePO4 pack, 280 Ah, a JK Inverter BMS guarding the pack, and a Victron SmartShunt 500 A in the negative cable. The pack rests at 52.8 V. The Growatt screen shows 40% SOC. The shunt shows 65%.

The short answer. Yes. A Victron SmartShunt gives you a state of charge you can trust in an open-loop system. SOC means how full the battery is. Open-loop means the inverter has no data link to the battery. The shunt counts amp-hours in and out of the pack. It does not guess from volts. Wire it into the negative cable at the battery, set the charged volts from your charger’s absorption volts, then let it sync to 100% at full charge. The inverter still charges by volts. The BMS still guards the pack. But you will know, and that changes how you run the house.

The rig that showed two SOC numbers

It was a working build with a lying screen. The Growatt SPF 5000 ES sat on the wall. It ran in user-defined mode, its open-loop mode. The battery box held 16 LiFePO4 cells with a JK Inverter BMS. The pack read 52.8 V at rest: 3.30 V per cell, times 16 cells. The JK app showed 65% charge. The Growatt screen showed 40%. The owner had watched the Growatt screen drop from 100% to 0% in one evening, then throw error 5002, battery undervoltage. At the same time, the pack volts stayed steady. The shunt settled it. The shunt said 65%. The shunt was right. The inverter was guessing from volts, with no amp count, while the shunt counted amps in and out.

Why volts SOC fails on LiFePO4

LiFePO4 has a flat discharge curve. That is the whole snag. On a 12 V pack, the volts sit near 13.2 to 13.3 V from about 80% down to 30% SOC. On a 16S 48 V pack, the same flat stretch sits near 52.0 V. It cannot tell you if you are at 75% or 45%. A 16S pack sits near 52.0 V at rest in the flat mid part, near 3.26 to 3.32 V per cell from near 20% to 80% full. A 15S pack sits near 48.0 to 49.5 V.

Load makes it worse. Turn on a kettle or a pump, and the volts sag, so the inverter reads the pack as flatter than it is. Charge makes the reverse error: while the charger pushes amps in, the volts rise, and the inverter reads the pack as fuller than it is. The same pack can show three SOC numbers in one hour, with no change in the stored energy. On our rig, the pack at 65% read 40% on the Growatt screen under a kettle load. It read 90% ten minutes into a charge.

The table below shows the same pack at three moments. The stored charge never moves. The volts do. That is why volts cannot be the boss for SOC.

Moment16S pack voltsGrowatt screen SOCTrue SOC
At rest, no load52.2 VNear 60%65%
Kettle on, 1,200 W51.4 VNear 40%65%
Solar charge, 40 A in53.4 VNear 90%65%

Wait at least 30 minutes with no charge and no load before you trust a volt read. Right after charge, the volts read high from surface charge. It is not real full charge, and the read lies till it fades. This rest volt read is called OCV, the resting volts with no charge and no load. Even then, on LiFePO4, the rest read can only tell you full or near empty, not 40% from 70%. Read the why volts SOC is wrong on LiFePO4 guide for the full curve.

How the shunt counts

A shunt is a small block that counts the amps going in and out. Inside it is a precise resistor in the negative cable. A small circuit reads the volt drop across that resistor. The size of the drop tells the shunt how many amps flow, and which way. It checks that flow lots of times each second and adds it up. Amps out take from the count, and amps in add to it.

This is coulomb counting: it reads amp-hours, the real thing, not volts. A 280 Ah pack that has given up 140 Ah since full is at 50%. That is why the shunt beats the inverter screen.

The count needs a start point. That is where the sync comes in. The shunt resets to 100% when three things hold at once: volts past the charged volts, amps under the tail current, both held for 3 minutes. A short volt spike or a short dip in amps does not sync it. The pack must be truly full, and take just a small tail current, for three steady minutes. On our rig, the sync came at noon on a clear day. The pack sat past 54.9 V. The amps fell under 11.2 A. Both held for 3 minutes. The shunt showed 100%.

Wiring: one negative path, no bypass

The shunt sits in the negative cable, right at the battery. Only the battery negative joins BATTERY MINUS. Each load, the inverter, the charger, and the chassis ground join SYSTEM MINUS, in most set-ups through a negative busbar. If each amp goes through the shunt, the count is right. If any negative skips it, the count is wrong.

The common skip is a chassis ground or a small DC load wired straight to the battery negative, past the shunt. A 5 A load that skips the shunt for ten hours is 50 Ah the shunt never saw, near 18% of a 280 Ah pack, so the SOC reads high and the pack runs lower than the screen says. On our rig, a small DC light circuit was wired straight to the battery negative. It moved to the busbar.

A thin fused sense wire runs from battery plus to the shunt, with a 1 A slow-blow fuse. It powers the shunt and reads the battery volts. Keep it short and direct. If the fuse blows, the shunt goes dark and the count stops.

Mount the shunt close to the battery, with short cable runs. Torque the lugs well, and check them after the first week. In a damp or outside spot, use the sealed IP65 type. Wire it with the set off and the breaker open: battery negative to BATTERY MINUS first, then system negative to SYSTEM MINUS, then the sense wire to battery plus.

Settings that make the count honest

Set the battery size to the bank’s rated amp-hours. Then set the charged volts from your charger’s absorption volts. The table below lists each setting. Each row gives the 12 V basis, the 48 V 16S value for a 280 Ah bank, and how to set it. The 48 V column is a worked case, not a rule for every bank. Read your own absorption volts off your inverter set-points.

Setting12 V basis48 V, 16S, 280 AhHow to set it
Battery capacityBank rated Ah280 AhBank rated Ah
Charged voltage13.9 VAbout 54.9 V0.2–0.3 V below absorption
Tail current4% of capacity11.2 A4% of bank Ah
Charged detection time3 min3 minDefault
Peukert exponent1.051.05Lithium, not 1.25
Charge efficiency99%99%98% in some prints
Discharge floor10–20%10–20%Not 50%
Current threshold0.1 A0.1 ADefault

On a 12 V base, the Victron guide lists 13.9 V as the lithium figure. The rule behind it: set charged volts 0.2 to 0.3 V under your charger’s absorption volts, the top volt level your charger holds at the end of a charge. If your charger tops out at 14.2 V, 13.9 V is right. If it tops out at 14.6 V, 13.9 V is too low, and the shunt may sync too soon.

Tail current is 4% of size by default, 11.2 A on a 280 Ah bank. Charged detection time is 3 minutes: both must hold for 3 minutes before the shunt resets to 100%. Do not cut it short. Peukert is how fast big loads drain the pack: set it to 1.05 for lithium. Some charts list 1.01, both far from the lead-acid 1.25. Charge efficiency is 99%. The discharge floor is 10 to 20%. The stock set-point of 50% is a lead-acid value that calls the pack flat far too soon.

The 48 V worked example, with the trap

Say absorption is 55.2 V. Charged volts is 0.2 to 0.3 V under absorption, so about 54.9 V. Tail current is 4% of a 280 Ah bank: 280 × 0.04 = 11.2 A. The shunt syncs to 100% when the pack sits past 54.9 V while it takes less than 11.2 A, both held for 3 minutes. On our rig, those were the exact numbers. The pack hit 55.2 V at noon. The amps tapered to 4 A. The shunt synced at 100%.

Do not scale the 12 V figure by four: 13.9 V × 4 = 55.6 V, past a 55.2 V absorption volts. A shunt set to 55.6 V would never see the volt state met, so it would never sync, and the SOC would drift more each week. A 15S pack follows the same rule: absorption 51.75 V means charged volts about 51.45 V.

If it jumps to 100% too soon

The shunt can jump to 100% while the pack is still far from full, when the charged volts is set too low or the tail current is set too high. On a 48 V bank, a charged volts of 54.0 V can be hit long before the pack is full. The fix is to lift the charged volts and cut the tail current. Installers fix this by cutting the tail current toward 1.5% and lifting the charged volts toward 55.2 V on a 48 V bank. This is a field fix, not a new default. Use the 4% default first, and move toward 1.5% only if the shunt syncs too soon. Do not start at 1.5%: loads that stay on while you charge, like a fridge, can hold the amps past a low tail current, and then the shunt never hits 100%.

Set it up in order: nine steps, each with a check

Work the steps in order. If a check fails, stop there.

  1. Pick the shunt size. Size it by the most amps the set will draw in a steady way, not by the battery size. A 48 V set that pulls 10 kW draws about 200 A, so a 500 A shunt covers it. Check: the shunt rating is above your peak steady amps.
  2. Wire the negative path. Wire it with the set off and the breaker open. Battery negative to BATTERY MINUS first, then system negative to SYSTEM MINUS, then the sense wire to battery plus. Check: only the battery negative sits on BATTERY MINUS.
  3. Fit the fused sense wire. Run a thin fused sense wire from battery plus to the shunt, with a 1 A slow-blow fuse. Keep it short and direct. Check: the fuse is in place, and the shunt powers up.
  4. Check volts and amps in VictronConnect. Check the volts match a meter at the lugs. Turn on a known load and check the amps read the right way. Check: volts match the meter, and amps read the right way.
  5. Set the battery size. Set the battery size to the bank’s rated amp-hours. For our rig, 280 Ah. Check: the size reads 280 Ah.
  6. Set charged volts from absorption. Set charged volts 0.2 to 0.3 V under your charger’s absorption volts. For our rig, absorption 55.2 V, so charged volts about 54.9 V. Check: charged volts reads about 54.9 V.
  7. Set tail current and time. Set tail current to 4% of size, 11.2 A on a 280 Ah bank. Set charged detection time to 3 minutes. Check: tail reads 11.2 A, time reads 3 minutes.
  8. Run a full charge and watch the sync. Charge the pack to full on a clear day with light loads. Watch the pack sit past 54.9 V while the amps fall under 11.2 A, both held for 3 minutes. Check: the shunt shows 100%.
  9. Compare the shunt and the inverter for a week. Watch the two SOC numbers each day. The shunt should move a bit when a load turns on. The inverter screen will jump. Check: the shunt SOC moves smoothly.

Sync, drift, and the weekly full charge

SOC drifts if the pack never gets a full charge. The pack swings from 40% to 80% and never nears the top, so the shunt never gets its sync. After a few weeks with no sync, the pack can hit the low-volt cut-off while the screen still shows 30%. On our rig, a cloudy week left the pack between 45% and 75% for nine days. The shunt drifted 6 points low by day nine. A clear day fixed it. The pack hit full, the shunt synced, and the count was true again.

Run a full charge each week, once a month at the least. A full charge means the pack hits absorption, the amps taper down past the tail current, and all three sync states hold for 3 minutes. On sun power, that tends to mean a clear day with light loads. On grid power, let the charger end its run.

When the SOC looks wrong, check the sync first. Open VictronConnect and look at the time since the last full charge. If it has been weeks, the number is not safe to trust till the next sync. If the pack did hit full charge and the shunt still did not sync, check the charged volts next to absorption.

If the reading differs, the reading is the answer

Work down the list in order. The table below splits the fault by what you see. Read the row that matches. Each row names the cause. Each row gives the fix. Check the wire job first. Then the size. Then the charged volts. Then the time since the last sync. Do not change two settings at once. You will not know which change fixed it.

What you seeMost likely causeFix
SOC reads high, pack cuts out soonA skipped negative, or size set too highCheck BATTERY MINUS; check the size
SOC never hits 100%Charged volts too high, or tail too lowLower charged volts; raise the tail current
SOC jumps to 100% too soonCharged volts too low, or tail too highLift charged volts; cut the tail toward 1.5%
SOC jumps in steps, or it sticksBluetooth link, or the fused sense wireCheck the link and the 1 A fuse
Small amp flow with no loadZero error in the shuntZero-current calibration in VictronConnect
Inverter SOC falls off a cliffInverter guesses from voltsTrust the shunt; check the inverter cut-off

Check for a zero error too. If the shunt reads a small amp flow with no load, it has a zero error. Fix it with a zero-current calibration, covered in the Victron guide in section 7.2.13.

A shunt will not fix a comms fault: if your inverter shows a BMS comms alarm, the shunt does not clear it. The Growatt Error 20 fix covers that fault on Growatt. The Solis CAN fail and BMS comm fail alarm 2015 fix covers it on Solis.

Which shunt, and what about a GX device

The SmartShunt comes in 500 A, 1000 A, and 2000 A types, plus an IP65 type for wet or outside spots. Size it by the most amps the set will draw in a steady way, not by the battery size. A 48 V set that pulls 10 kW draws about 200 A, so a 500 A shunt covers it. There is no screen on a SmartShunt; you read it by Bluetooth in the VictronConnect app. The BMV-712 is the same counter with a screen, and it uses the same set-points.

If the battery BMS already talks to a Victron GX box, like a Cerbo GX, let the BMS drive the charge set-points. Do not beat them in the SmartShunt. The GX box is the boss in a Victron set-up. The shunt is the cross-check. In our rig, there was no GX box. The shunt was the boss for SOC. The JK BMS was the boss for cell guards.

SmartShunt and Solar Assistant

Lots of open-loop users pair the shunt with Solar Assistant, a small box that reads your kit and shows the data on a screen or a phone. The inverter on its own cannot show true SOC in open-loop. It has no link to the battery. Solar Assistant reads the shunt and shows the shunt SOC next to the inverter data. This is a read-out fix, not a charge fix. The inverter still charges by volts. The BMS still guards the pack.

What can still go wrong

The skipped wire.

One box sleep wire or one MPPT sense lead bolted straight to the pack skips its amps past the shunt. The count goes wrong from that day on. Check every negative. All of them go through SYSTEM MINUS.

The wrong charged volts.

A charged volts set to 55.6 V by scaling the 12 V figure by four will never sync. Set it from your own absorption volts. Read the volts off your inverter set-points.

The no-full-charge drift.

A pack that never hits full will drift. After weeks, the screen can read 30% while the pack hits the low-volt cut-off. Run a full charge weekly. Check the time since the last sync.

The comms fault trap.

A shunt does not clear a BMS comms alarm. If the inverter shows Error 20, fix the link first.

Common questions

Does a SmartShunt fix the inverter SOC screen?

No. The inverter still guesses from volts. The shunt gives you a true SOC on your phone, in VictronConnect. The inverter screen stays wrong in open-loop mode.

Which shunt size do I need?

Size it by peak steady amps, not by battery size. A 48 V set that pulls 10 kW draws about 200 A, so a 500 A shunt covers it.

Why does my shunt never sync to 100%?

The charged volts is set too high, or the tail current is set too low for the loads that run while you charge. Check charged volts against absorption first, then the tail current.

Why does my shunt jump to 100% too soon?

The charged volts is set too low, or the tail current is set too high. Lift the charged volts toward absorption.

Do this next

  1. Wire the shunt into the negative cable at the battery. Put only the battery negative on BATTERY MINUS, and all else on SYSTEM MINUS through a busbar.
  2. Fit the fused sense wire from battery plus, with its 1 A slow-blow fuse.
  3. Set the size to the bank’s rated amp-hours, the charged volts 0.2 to 0.3 V under absorption, tail current to 4% of size, and the discharge floor to 10 to 20%.
  4. Run a full charge and watch the shunt sync to 100% in VictronConnect.
  5. If the SOC moves just a bit when a load turns on, the count is good.
  6. Run a full charge weekly. Check the time since the last sync when the SOC looks wrong.

Sources

Checked on 20 November 2026. Unconfirmed items are labelled “not confirmed” in the text.

QUESTIONS ANSWERED

Operator Questions Answered (Playbook FAQ)

Switch off the battery rack breaker, DC isolator, and AC input before handling RJ45 plugs on Hybrid Inverter LiFePO4 BMS. Powered down, measure DC resistance across Pins 4 (CAN-H) and 5 (CAN-L)—a healthy terminated bus reads ~60Ω (two 120Ω resistors in parallel), while 120Ω indicates one missing end resistor.

Farhan Ahamed
WRITTEN & AUDITED BY

Farhan Ahamed

Founder & Lead Protocol Architect • BMSBridge.online

Hardware diagnostics engineer specializing in 500 kbps CAN-Bus telemetry (0x351–0x35E), RJ45 VE.Can crossovers, and cell-safe 15S/16S LiFePO4 battery interoperability.