What this guide works from. One rig: a Sol-Ark 15K-2P, a Pylontech US5000 pack, 15 cells, the pack resting at 51.8 V, the pack screen showing 49% charge, and the Sol-Ark home screen showing volts only.
The short answer. On a Sol-Ark 15K-2P, the battery talks through one RJ45 socket. It is called Battery CANBus. CAN-H is pin 4. CAN-L is pin 5. Ground is pin 6. Build a cable with only those three wires for a CAN battery. Set the inverter to BMS Lithium Batt 00. Set battery ID 00. Turn on Activate Battery. On our rig, the fault was the port. The cable sat in the separate Modbus RS485 port, not the Battery CANBus port. We moved one plug. The LI Batt Info screen filled in within two minutes.
The rig that would not link
It was a new build, and it looked right. The Sol-Ark 15K sat on the wall, and the US5000 pack sat below it. The pack read 51.8 V: 3.45 V per cell, times 15 cells. The pack screen showed 49% charge. Then the inverter was switched on. The home screen showed pack volts, but no SOC and no battery data. State of charge, or SOC, is how full the battery is. The proof is the LI Batt Info screen. When CAN comms are on, that screen shows the battery data the inverter gets from the BMS. On our rig, LI Batt Info was blank. The inverter ran on volts alone.
What the pins carry
The Battery CANBus port on the Sol-Ark 15K-2P is one single RJ45 socket. The pin table here comes from the 15K install manual MA-00007 Rev. 12, part 2.3. Count pins with the clip facing away from you, pin 1 on the left. Pin 1 is RS-485 B-. Pin 2 is RS-485 A+. Pin 3 has no link. Pin 4 is CAN Hi. Pin 5 is CAN Lo. Pin 6 is GND. Pin 7 is RS485 A+. Pin 8 is RS485 B-. RS485 is another two-wire link, older and slower than CAN. Two RS485 pairs sit in the same socket, on pins 1 and 2 and again on pins 7 and 8. The CAN pins are the firm part: pin 4 is CAN-H, pin 5 is CAN-L, and pin 6 is ground, and those three match in each source checked for this guide.
| Pin | Wire | What it does. |
|---|---|---|
| 1 | RS485 B- | RS485 data, B side. Order disputed, see below. |
| 2 | RS485 A+ | RS485 data, A side. Order disputed, see below. |
| 3 | No link | No battery wire here. |
| 4 | CAN-H | CAN data, high line. |
| 5 | CAN-L | CAN data, low line. |
| 6 | GND | Signal ground. |
| 7 | RS485 A+ | RS485 data, A side, pair 2. |
| 8 | RS485 B- | RS485 data, B side, pair 2. |
The wire colors in guide TB-00012 line up with the T568B order. For CAN, pin 4 is solid blue, pin 5 is white/blue, and pin 6 is solid green. For Modbus RS485, pin 6 is solid green, pin 7 is white/brown, and pin 8 is solid brown. Modbus is a set of rules for how devices talk over RS485. Pin 3 has no link on the Battery CANBus port, so a wire landed there does nothing at the inverter end. That does not make it safe to leave in the plug. On the battery end, the same pin may carry a signal your battery maker uses. That is why this guide names only three pins for each cable type, and why the rest are cut back. Only the Battery CANBus port is used for battery comms on the 15K. The separate Modbus RS485 port is not for battery comms, with one case named in the guide: Storz batteries.

Which setting fits your battery
Set the inverter to BMS Lithium Batt 00. Set battery ID 00. That is the setting named in the guide. It is the first menu check when a link will not come up. If an outside device uses BMS Lithium Batt 00 too, change the inverter Modbus SN to 01. The stock value is 00. Two devices on the same address will clash. In closed-loop mode the inverter follows the BMS limits. Closed-loop means the inverter and the BMS talk to each other. So a limit set too low in the BMS turns into a slow charge even on a sunny day. Turn on Activate Battery. The guide says this choice must be picked if the system has batteries. It sits in the battery setup menu. If it is off, the inverter may see the pack volts and still show no battery data. Pick it, save, and wait a minute.
| Inverter and port | CAN cable: pins kept | Modbus RS485 cable: pins kept | Settings to check first |
|---|---|---|---|
| Sol-Ark 15K-2P, single Battery CANBus port | Pin 4 CAN-H, pin 5 CAN-L, pin 6 GND | Pin 6 GND, pin 7 RS485+, pin 8 RS485- | BMS Lithium Batt 00, battery ID 00 |
| Sol-Ark outdoor 12K, single Battery CANBus port | Pin 4 CAN-H, pin 5 CAN-L, pin 6 GND | Pin 6 GND, pin 7 RS485+, pin 8 RS485- | BMS Lithium Batt 00, battery ID 00 |
| Sol-Ark legacy indoor 12K, CAN port and RS-485 port | CAN port: pin 4 CAN-H, pin 5 CAN-L, pin 6 GND | RS-485 port: pin 6 GND, pin 7 RS485+, pin 8 RS485- | BMS Lithium Batt 00, battery ID 00 |
| Battery end, per its own manual | Match pins 4, 5, 6 at the inverter | Match pins 6, 7, 8 at the inverter | Check A/B order and the battery address |
Check the firmware too. Sol-Ark says the inverter firmware must be up to date for Modbus RS485 comms. You need Comm v143F or newer. Comm is the comms board firmware. If your Comm version is older than v143F and you run a Modbus battery, update it first. A CAN battery does not need this step in the same way. But an old firmware can still hide menu items. Note the version before you start. The outdoor 12K shares the same single Battery CANBus port as the 15K. The older indoor 12K has two separate RJ45 ports, one marked CAN and one marked RS-485, with the same pin table per the guide. The full EG4 pairing is the JK BMS to EG4 6000XP and 18kPV closed-loop setup.
Why the pin order matters
A dead Sol-Ark link is a handshake fault. A handshake is the short exchange where two units agree they can talk. The inverter sends a frame on the CAN bus: one short packet of data. The BMS must answer with its own frame: SOC, charge limit, cell volts, temps, alarms. If no answer comes back in time, the inverter shows volts only and stops trusting the pack. The talk failed. That talk can fail in only four ways: the wire is wrong, the port is wrong, the setting is wrong, or the bus is broken. A reboot fixes none of these.
CAN works as a pair. CAN-H and CAN-L are two wires that move in step, one up and one down. The twist in the pair cancels noise from near wires. That is why the two CAN wires must sit on the same twisted pair in the cable, most often the blue pair in T-568B, pins 4 and 5. If CAN-H and CAN-L are swapped, each line still sits near 2.5 V at rest. The meter looks fine, but no frame gets through. The bus is dead, and the volts lie to you.
A straight Ethernet cable is the most common wire fault here. An Ethernet patch cable is wired pin to pin and built for a network switch. A BMS cable is not a network cable. The Sol-Ark Battery CANBus port puts CAN, RS485, and ground on different pins in one socket, and the battery end puts its own signals on its own pins. A straight cable joins all eight at once. For a CAN battery, guide TB-00012 says the cable keeps only pins 4, 5, and 6 linked. For a Modbus RS485 battery, it keeps only pins 6, 7, and 8. Use shielded Cat5e or Cat6, and keep it away from DC and AC wiring.
Fix it in order: nine steps, each with a check
Work the steps in order. If a check fails, stop there.
- Write down what you have. Note the inverter model, battery brand, and Comm firmware version. Check: model names, Comm version, and photos in hand.
- Cut the power before you touch a plug. Switch the battery breaker, DC isolator, and AC breaker off. Wait until the screen is dark. Check: screen dark, battery breaker off.
- Check the port. On the 15K, the battery cable goes in the socket marked Battery CANBus, never the Modbus RS485 port unless your battery is a Storz named in the guide. On our rig, this was the fault: the cable sat in the Modbus RS485 port, so we moved it to the Battery CANBus port. Check: plug in the Battery CANBus port.
- Build the cable. For CAN, blue to pin 4, white/blue to pin 5, green to pin 6, and nothing else in the plug. For Modbus, green to pin 6, white/brown to pin 7, brown to pin 8, and nothing else. Cut the other five wires back at the jacket and tape the cut ends. Check: only three wires in the plug.
- Meter the cable before you plug it in. Check that each wire runs all the way through, pin to pin. Then check that no pin is shorted to the one next to it. One stray strand of wire between pins 4 and 5 will hold the CAN bus down. Check: each wire runs end to end, no shorts between pins.
- Set the inverter. Set BMS Lithium Batt 00 and battery ID 00. Turn on Activate Battery. If an outside device uses BMS Lithium Batt 00, change the inverter Modbus SN to 01. Check: BMS Lithium Batt 00, battery ID 00, Activate Battery on.
- Test the bus with a meter. With all power off, test ohms between CAN-H and CAN-L. A good bus reads about 60 ohms (two 120 ohm end resistors in parallel). With power on and the bus idle, test each line to ground: each should sit near 2.5 V DC. On our rig, the power-off test read 60 ohms, and the idle test read 2.5 V on each line. Check: about 60 ohms power off, about 2.5 V per line power on.
- Power up in order and check LI Batt Info. Switch the battery on first, then the inverter, and wait two full minutes. Open the LI Batt Info screen. That screen shows the battery data the inverter gets from the BMS. On our rig, LI Batt Info filled in after about 40 seconds, and it showed 49% SOC, the same number the pack screen showed. Check: LI Batt Info shows live data, SOC matches the pack.
- Prove it under load. Put a load on the inverter and watch the SOC move, then charge the pack and watch it climb. On our rig, a 1,200 W kettle load pulled the SOC from 49% to 48% over ten minutes. On charge, the SOC reached 100% as the pack hit 51.75 V: 15 cells times 3.45 V per cell. Check: SOC moves with charge and discharge, and it reaches 100% without jumping.

If the reading differs, the reading is the answer
A meter can rule out a dead link in minutes. It cannot read CAN frames, but it can tell you if the bus is shorted or open. All volt numbers are DC to ground, on a fast CAN bus built to ISO 11898-2. On a live bus with traffic, a plain meter shows the average: CAN-H reads 2.6 to 3.0 V and CAN-L reads 2.0 to 2.4 V. Only an oscilloscope shows the true peaks: CAN-H toward 3.5 V, CAN-L toward 1.5 V. You do not need one here.
| Reading | What it means. | What to do. |
|---|---|---|
| About 60 ohms, power off. | Both 120 ohm end resistors are there. | Go to Step 8. |
| Near 120 ohms, power off. | One end resistor is missing. | Check the battery manual for the end cap. |
| Open circuit, power off. | No termination, a broken wire, or the plug is in the wrong port. | Check the port first, then test the cable. |
| Near zero ohms, power off. | A short between CAN-H and CAN-L. | Unplug each end in turn. If the short stays with the cable, replace the cable. |
| 2.5 V on each line, power on, idle. | Bus idle and healthy, but nobody is talking. | Check the setting and the BMS power. |
| 2.6–3.0 V on CAN-H, 2.0–2.4 V on CAN-L. | Traffic is flowing. The link is alive. | Go to Step 8. |
| LI Batt Info blank, volts fine. | Link is down. Home screen volts lie. | Work Steps 3, 6, and 7 in order. |
Where the end cap sits rests on the battery, so read your battery manual before you add one. Do not add an end cap to a bus that already reads 60 ohms. If RS485 will not link, swap A and B at one end only, then test again.

What each symptom points to
| What you see. | Most likely cause. | Fix. |
|---|---|---|
| Home screen shows volts only, LI Batt Info blank. | Cable in the wrong port, or Activate Battery off. | Steps 3 and 6: Battery CANBus port, Activate Battery on. |
| No battery after a firmware update. | Settings moved, or Comm version too old for Modbus. | Check BMS Lithium Batt 00, then Comm v143F. |
| Link drops at noon or under load. | Cable run tight against DC or AC wiring picks up noise. | Move the comms cable away from power cables and shorten it. |
| Two devices clash on the same address. | Outside device uses BMS Lithium Batt 00 too. | Change the inverter Modbus SN to 01. |
| Slow charge on a sunny day. | BMS limit set too low, inverter follows it in closed-loop. | Check the BMS charge limit. |
| RS485 will not link at all. | A and B flipped on pins 1 and 2. | Read your own manual, then swap A and B at one end. |
The RS485 A/B conflict: read your own manual first
Here is the one place where the sources do not agree, and a swapped A/B pair looks just like a dead cable. The printed table in manual MA-00007 Rev. 12, part 2.3, lists pin 1 as RS-485 B- and pin 2 as RS-485 A+. Another text copy of the same manual prints pin 1 as RS-485 A+ and pin 2 as RS-485 B-. The two are swapped. The CAN pins 4 and 5 and ground pin 6 match in each source. Only the RS485 A/B order on pins 1 and 2 is in doubt. The printed table in the manual you hold is the better source. Before you crimp an RS485 cable for pins 1 and 2, open your own manual and read pins 1 and 2 as printed there. Do not trust a web copy over the book that came with your inverter. Check the A and B order at both ends before you crimp. A flipped pair just stays silent. For CAN, this conflict does not touch you: pins 4 and 5 are firm, and a CAN battery does not use pins 1 and 2 at all.

When the link will not hold, run on volts
If the link will not come up tonight, run open-loop for the night. Do not force a cable. Set the inverter to volt mode. Set the charge volts from the battery datasheet and the BMS limits. Let the BMS guard the pack. For a 15S pack: 51.75 V bulk, 50.25 V float, 45.0 V cut-off (15 × 3.45 V, 15 × 3.35 V, 15 × 3.0 V). For a 16S pack: 55.2 V bulk, 53.6 V float, 48.0 V cut-off. A 15S pack and a 16S pack do not share the same full-charge volt. See the volt guide in the EG4 6000XP and 18kPV voltage mode fallback and the open-loop LiFePO4 voltage settings before you set the volts. Come back to the link in daylight.
What can still go wrong
A JK BMS pack is not an approval.
A JK Inverter BMS speaks Pylontech CAN on pins 4 and 5. That lines up with the Sol-Ark CAN pins. But a pin match is not an approval. JK is not checked here as a named battery on Sol-Ark’s approved list. Treat this as field practice only. Check the guide for your battery. Test the link before you trust it with a house load. If you try a JK pack, use its CAN socket. Wire H to H and L to L. Read the print on your own board first. Restart the BMS after a protocol change. The Deye version of the same JK setup is the JK BMS to Deye hybrid inverter protocol.
The cable that worked yesterday.
A comms cable run tight against DC lugs or AC wires can pick up noise when current peaks. That is why a fault that clears in the morning can come back at noon. If the link drops under load, move the cable and shorten it.
The firmware that moved the menu.
If the fault shows only after a firmware update, check the settings again. A firmware update can move menu items and rename codes. The Deye version is the Deye no battery after firmware update fix.
Common questions
Which port takes the battery cable on a 15K?
The Battery CANBus port. The separate Modbus RS485 port is not for battery comms, unless your battery is a Storz named in the guide.
What are the CAN pins on a Sol-Ark?
CAN-H is pin 4, CAN-L is pin 5, ground is pin 6. Those three pins agree in every source.
Why is LI Batt Info blank when the home screen shows volts?
The link is down. LI Batt Info is the proof the link works.
Do I need Comm v143F for CAN?
No. Sol-Ark names Comm v143F or newer for Modbus RS485 comms. A CAN battery does not need it.
Pins 1 and 2: A+ first or B- first?
The sources disagree. Read the printed table in the manual that came with your inverter, and check the battery end too. For CAN, this conflict does not touch you.
Do this next
- Write down model names and the Comm firmware version, and take a photo of the battery setup menu.
- Build a 3-wire cable by hand and meter it: CAN blue to pin 4, white/blue to pin 5, green to pin 6, and nothing else in the plug.
- Plug it into the Battery CANBus port, never the Modbus RS485 port unless your battery is a Storz named in the guide.
- Set BMS Lithium Batt 00 and battery ID 00, and turn on Activate Battery. Check Comm is v143F or newer for Modbus.
- Test the bus: about 60 ohms with power off, about 2.5 V per line with power on and idle.
- Power the BMS, then the inverter, and look at LI Batt Info for live data that matches the pack screen.
- Still stuck? Call Sol-Ark support with model names, the settings, and meter readings.
Sources
Checked on 20 November 2026. Unconfirmed items are labelled “not confirmed” in the text.
- Sol-Ark 15K install manual MA-00007 Rev. 12, part 2.3. Battery CANBus port: pin 1 RS-485 B-, pin 2 RS-485 A+, pin 3 no link, pin 4 CAN Hi, pin 5 CAN Lo, pin 6 GND, pin 7 RS485 A+, pin 8 RS485 B-.
- Sol-Ark guide TB-00012. CAN cable keeps pins 4, 5, and 6. Modbus RS485 cable keeps pins 6, 7, and 8. BMS Lithium Batt 00, battery ID 00. Activate Battery. Comm v143F or newer for Modbus RS485. Modbus RS485 port not for battery comms, except Storz batteries.
- Sol-Ark text extraction of MA-00007 Rev. 12. Pin 1 RS-485 A+, pin 2 RS-485 B-. Conflicts with the printed table on pins 1 and 2 only. Not confirmed which copy is right.
- ISO 11898-2 CAN standard (PCBCool, Apex Control, SCADA Protocols). Idle 2.5 V per line. Dominant 3.5 V / 1.5 V. 120 ohm per end, about 60 ohms measured.
- JK BMS community reports. JK Inverter BMS speaks Pylontech CAN on pins 4 and 5. JK is not checked here as a named battery on Sol-Ark’s approved list. Field practice only.
- This site: JK BMS to EG4 6000XP and 18kPV closed-loop setup, Deye & Sunsynk BMS port pinout, JK BMS to Deye hybrid inverter protocol, Deye no battery after firmware update fix, EG4 6000XP and 18kPV voltage mode fallback, open-loop LiFePO4 voltage settings.
Comments (0)