What this guide works from. One rig: an EG4 6000XP, a JK Inverter BMS (PB series, JK-PB2A16S20P) on a 16-cell LiFePO4 pack, 280 Ah, resting at 52.8 V, JK app showing 47% charge, W000 on boot.
The short answer. Yes, a JK Inverter BMS can talk to an EG4 6000XP and an EG4 18kPV. The link is CAN. Set the JK CAN protocol to Luxpower, code 11 in the JK app. Set the inverter battery type to 0, the EG4 code. Wire CAN-H to CAN-H and CAN-L to CAN-L on pins 4 and 5 only. On our rig, the fault was the brand number: the menu was set to 1, because one part of the 6000XP manual lists 1 for EG4 batteries. The working field reports use 0. We set brand 0, kept Luxpower 11, and W000 cleared in under two minutes. If the link fails, chase W000 on these two models, not Error 19.
The rig that would not link
It was a new build, and it looked right. The 6000XP sat on the wall, and the battery box held 16 LiFePO4 cells. A JK Inverter BMS sat on top of the pack. The pack read 52.8 V: 3.30 V per cell, times 16 cells. The JK app showed all 16 cells between 3.29 V and 3.31 V, and 47% charge. Then the inverter was switched on. W000 showed within seconds. W000 is Warning 00, “Communication failure with battery.” The home screen showed a volt number but no state of charge. State of charge, or SOC, is how full the battery is. The inverter still saw 52.8 V on the DC cables, but it had no data: no SOC, no charge limit, no cell temps. Without data, the inverter will not trust the battery. In closed-loop mode it waits for BMS frames.
Which JK board can talk to an EG4
Only the JK Inverter BMS can do this on its own. That is the PB series. Look for the PB board. It has RJ45 sockets marked CAN and RS485-1. It also has RS485-2 for packs wired in parallel. And it has a DIP switch block. A common model is the JK-PB2A16S20P. PB boards fit packs from 8S to 16S. DIP switches are tiny switches on the BMS board. They set the pack address.
The older JK-B boards are small smart BMS boards. They use Bluetooth only. They do not speak Luxpower CAN to an inverter on their own. They need a bridge, a small board that reads the JK-B and sends CAN frames to the inverter.
JK is not on EG4’s approved list as a named battery. Say that in plain words: you run a Luxpower-compatible profile, not an EG4-approved JK pairing.
What the pins carry
The 6000XP BMS port carries both links. That is the first trap: the wrong wire in the right port still fails. The table below is the pin map for that port. The full guide is the EG4 6000XP & 18kPV battery communication pinout. For a CAN link, only pins 4 and 5 matter: CAN-H to CAN-H, CAN-L to CAN-L. For an RS485 link, only pins 1 and 2 matter. Do not wire both links at once. One warning about the JK side: JK’s own papers disagree on which pin is CAN-H and which is CAN-L on some boards. This is not confirmed as a misprint in either sheet, so this guide does not pick a winner. Read the print on your own board and wire H to H and L to L from that print. Step 6 will catch a swap.
| Pin | Wire | What it does. |
|---|---|---|
| 1 | RS485B | RS485 data, B side. |
| 2 | RS485A | RS485 data, A side. |
| 3 | Not used | No battery wire here. |
| 4 | CAN-H | CAN data, high line. |
| 5 | CAN-L | CAN data, low line. |
| 6 | Not used | No battery wire here. |
| 7 | Not used | No battery wire here. |
| 8 | Not used | No battery wire here. |
On the 6000XP BMS port, manual v1.7.3 lists pin 1 RS485 BMS_485 B, pin 2 RS485 BMS_485 A, pin 4 CAN BMS_CAN H, and pin 5 CAN BMS_CAN L. On the 18kPV the same pins carry the same signals under BAT names. Count pins with the clip facing away from you. Pin 1 is on the left.

Which setting fits your battery
The 6000XP battery voltage range for lithium is 46.4 to 60 V. Top charge current is 125 A. Top discharge current is 140 A. On the 6000XP, the battery setting is Setting 3, marked Battery: Lead-Acid, or Li-ion and then a brand number. For a JK in closed-loop, pick Li-ion and enter the brand number for EG4, which is 0 in the field reports that work.
| Battery and inverter | Link and port | Inverter setting | JK side |
|---|---|---|---|
| EG4 battery with 6000XP / 18kPV | CAN, battery CAN port to BMS port. | Battery type 0 (EG4). | CAN protocol: Luxpower or Pylontech. |
| JK Inverter BMS with 6000XP / 18kPV | CAN, BMS CAN port to BMS port. | Battery type 0 (EG4). | CAN protocol: Luxpower, code 11, 500 kbps. |
| JK Inverter BMS with 6000XP / 18kPV, Luxpower will not link | CAN, BMS CAN port to BMS port. | Battery type 0 (EG4). | CAN protocol: Pylontech, 500 kbps. |
| JK Inverter BMS with 6000XP / 18kPV, no comms at all | No data cable. | Voltage mode. | BMS guards the pack, inverter follows volts only. |
The same manual also says 1 for EG4 batteries in another place. The numbers do not match between manual passages. Test on your firmware. Start with 0. If 0 gives you W000 and no SOC, try 1, then 6, the LuxPower code. Test each one on its own, with a BMS power cycle in between.
On the 18kPV, set Battery Type to Lithium, then pick 0 for EG4 under Lithium Batteries. That 0 is the same number the working field reports use. Advanced settings on the 18kPV need the password 00000.

Why the inverter cannot hear the battery
W000 is a handshake fault. A handshake is the short exchange where two units agree they can talk. The inverter sends a frame on the CAN bus: one short packet of data. The BMS must answer with its own frame: SOC, charge limit, cell volts, temps, alarms. If no answer comes back in time, the inverter raises W000 and stops trusting the pack. The talk failed. That talk can fail in only four ways: the wire is wrong, the port is wrong, the protocol is wrong, or the bus is broken. A reboot fixes none of these. It changes nothing about the wire, the protocol, or a DIP switch set for the wrong speed. One rare case: the BMS was asleep and woke up during the power cycle. That is luck, not a fix.
A plain Ethernet patch lead is the most common wire fault. It fits. It clicks. It fails. A network patch cable is wired pin to pin. It is built for a network switch. The 6000XP BMS port and the JK CAN port put different signals on different pins. On some JK PB boards CAN-H and CAN-L are swapped next to the inverter. A straight cable can put CAN-H onto CAN-L. Build the cable by hand. Use a short run of shielded twisted-pair cable, Cat5e or Cat6. Keep CAN-H and CAN-L on the same twisted pair. In T-568B that is the blue pair, pins 4 and 5.
Fix it in order: nine steps, each with a check
Work the steps in order. If a check fails, stop there.
- Write down what you have. Note the inverter model, battery and BMS brands, and the code. Photograph Setting 3 and the DIP switches. Check: model names and photos in hand.
- Cut the power before you touch a plug. Switch the battery breaker, DC isolator, and AC breaker off. Wait until the screen is dark. Check: screen dark, battery breaker off.
- Check the cable with your eyes and hands. Pull the plug at each end and look for a bent pin, a plug that does not click home, and a crushed cable. If you have a spare cable you know is good, swap it in now. Check: both plugs click home, no bent pins.
- Check the ports. On the inverter, the battery cable goes in the socket marked BMS. On the JK BMS, it goes in the socket marked CAN. Not RS485-1. Not RS485-2. Check: plug in the CAN port at the BMS end and the BMS port at the inverter end.
- Set the inverter menu. On the 6000XP, go to Setting 3, pick Li-ion, and enter brand 0 for EG4. On the 18kPV, set Battery Type to Lithium, then pick 0 for EG4. Do not pick a code for another brand because it looks close. Each code loads a different frame set. On our rig, this was the fault: the menu showed brand 1. We changed it to 0. Check: brand still reads 0.
- Set the JK app to match. Open the JK app over Bluetooth. Go to the protocol settings. Pick the Luxpower CAN protocol, code 11 on the boards that show numbers. Set the CAN speed to 500 kbps if the app shows it. If Luxpower will not link, try Pylontech CAN as the second try. Do not change the inverter code and the JK protocol in the same step. Check: JK app shows CAN Luxpower 11, 500 kbps.
- Set DIP 1000 and test the bus with a meter. For one pack, set DIP 1000: switch 1 ON, switches 2, 3, and 4 OFF. That sets the pack as address 0, the master. With all power off, test ohms between CAN-H and CAN-L. A good bus reads about 60 ohms (two 120 ohm end resistors in parallel). With power on and the bus idle, test each line to ground: each should sit near 2.5 V DC. On our rig, the power-off test read 61 ohms, and the idle test read 2.5 V on each line. Check: DIP 1000 set, about 60 ohms power off, about 2.5 V per line power on.
- Power up in order and wait two minutes. Switch the battery on first, then the inverter, and wait two full minutes. W000 still on the screen means the inverter is still trying to shake hands with the BMS. A clear screen and a real SOC reading mean the link is up. On our rig, W000 cleared after about 40 seconds, and the screen showed 47% SOC, the same number the JK app showed. Check: W000 gone, SOC matches the BMS app.
- Prove it under load. Put a load on the inverter and watch the SOC move, then charge the pack and watch it climb. On our rig, a 1,200 W kettle load pulled the SOC from 47% to 46% over ten minutes. On charge, the SOC reached 100% as the pack hit 55.2 V: 16 cells times 3.45 V per cell. Check: SOC moves with charge and discharge, and it reaches 100% without jumping.

If the reading differs, the reading is the answer
A meter can rule out a dead link in minutes. It cannot read CAN frames, but it can tell you if the bus is shorted or open. All volt numbers are DC to ground, on a high-speed CAN bus built to ISO 11898-2. On a live bus with traffic, a plain meter shows the average: CAN-H reads 2.6 to 3.0 V and CAN-L reads 2.0 to 2.4 V. Only an oscilloscope shows the true peaks: CAN-H toward 3.5 V, CAN-L toward 1.5 V. You do not need one here.
| Reading | What it means. | What to do. |
|---|---|---|
| About 60 ohms, power off. | Both 120 ohm end resistors are there. | Go to Step 8. |
| Near 120 ohms, power off. | One end resistor is missing. | Check the BMS end resistor. |
| Open circuit, power off. | No termination, a broken wire, or the plug is in a port with no CAN pair. | Check the port first, then test the cable. |
| Near zero ohms, power off. | A short between CAN-H and CAN-L. | Unplug each end in turn. If the short stays with the cable, replace the cable. |
| 2.5 V on each line, power on, idle. | Bus idle and healthy, but nobody is talking. | Check the protocol and the BMS power. |
| 2.6–3.0 V on CAN-H, 2.0–2.4 V on CAN-L. | Traffic is flowing. The link is alive. | Go to Step 8. |
| 0 V or pack volts on one line. | That line is shorted, or the signal chip is dead. | Stop. Unplug the BMS end. If the line clears, the fault is in the BMS. |
For RS485, the same idea holds with different pins. Flipped A and B is a common fault on third-party cables. If RS485 will not link, swap A and B at one end only, then test again.

What each symptom points to
| What you see. | Most likely cause. | Fix. |
|---|---|---|
| W000 on boot, volts but no SOC. | Wrong brand number, or protocol mix-up. | Steps 5 and 6: brand 0, then Luxpower 11. |
| W000 clears, then comes back at noon. | Cable run tight against DC or AC wiring picks up noise at peak current. | Move the comms cable away from power cables and shorten it. |
| W000 only after a firmware update. | Protocol list moved, or brand reset. | Re-check Setting 3 and the JK app protocol. |
| SOC stuck at 100%, pack volts still fall. | BMS volt calibration off, or RCV timer too long. | Check BMS volts with a meter. See below. |
| W027 on the screen. | Battery open, pack volts under 40 V. | Check the breaker, DC cables, and pack volts first. |
| W004 on the screen. | BMS blocks charge or discharge. | Read the JK app alarm flags. Not a cable fault. |
W000 is not Error 19
This is the fix that matters most in this article. The comms failure code on the 6000XP and the 18kPV is W000, Warning 00, “Communication failure with battery”. Fault 19 on the 6000XP is a different fault. It means bus voltage too high, and the manual says to check that PV is not above 480 Vdc. Error 19 means loss of battery comms only on the older 3000EHV, a different model. Do not chase Error 19 for a comms fault on a 6000XP or an 18kPV.
Other EG4 codes help too. W027 is battery open, and the field guide puts it at battery voltage under 40 V. Check the breaker, the DC cables, and the pack voltage before you touch the comms cable. W004 is battery fault, and it means comms are fine but the BMS blocks charge or discharge. That is a BMS-side fault, not a cable fault. Open the JK app, read the alarm or protection flags, and fix the fault the BMS reports.
When voltage mode is the right call
Closed-loop is better when it works. Open-loop is better than a broken closed-loop. Open-loop means the inverter works from voltage alone, with no BMS data. If the JK board has no CAN port, if the protocol will not link after a full check, or if you need the house running tonight, switch the inverter to voltage mode. Set the charge voltages from the battery datasheet and the BMS limits. Voltage-based SOC on LiFePO4 is rough, because the discharge curve is flat in the middle, so the inverter will guess SOC wrong. That fallback is in the EG4 6000XP and 18kPV voltage mode fallback guide and in Closed-Loop vs Open-Loop LiFePO4. For a 16S pack: 55.2 V bulk, 53.6 V float, 48.0 V cut-off (16 × 3.45 V, 16 × 3.35 V, 16 × 3.0 V). For a 15S pack: 51.75 V bulk, 50.25 V float, 45.0 V cut-off.
What can still go wrong
SOC stuck at 100%.
The BMS reads 100% for hours, the inverter stops charging, and the pack voltage still falls. Owners in the forums trace this to BMS voltage calibration. If the BMS reads a bit low, it never sees the top voltage that marks full. Check the BMS voltage against a meter. In the JK app, the per-cell charge voltage is RCV and the per-cell float voltage is RFV. One owner set the RCV timer to 0.1 hour, so the float request went out fast. If your SOC sticks at 100% while voltage drops, check calibration and the RCV and RFV timers before you blame the cable.
The JK V19 board is not the V15.
The V15 works in a plain way. The V19 has given owners more trouble in parallel banks. One report says slave packs send master data out of the RS485-2 port, and that bad data corrupts the CAN and RS485 links. If you run two or more V19 packs in parallel and comms break, check the RS485-2 wiring and the master and slave addresses first.
Common questions
Can a JK BMS talk to an EG4 6000XP at all?
Yes. Use CAN, Luxpower protocol 11 in the JK app, and battery type 0 on the inverter. Field reports confirm this pairing on the 6000XP and the 18kPV.
Is W000 the same as Error 19?
No. W000 is the comms fault on the 6000XP and 18kPV. Fault 19 is bus voltage too high. Error 19 is a comms fault only on the older 3000EHV.
Should I use brand 0 or brand 1 for EG4?
Start with 0. The manual lists both 0 and 1 for EG4 in different places. The working field reports use 0. Try 1, then 6, only if 0 fails.
Can I use a normal Ethernet cable?
Sometimes it fits and clicks, but it often fails. A straight patch lead can put CAN-H onto CAN-L. Build the cable by hand and meter it first.
Why does my SOC stick at 100%?
Check the BMS voltage against a meter. If the BMS reads low, it never sees the top voltage that marks full. Check the RCV and RFV timers in the JK app too.
Do this next
- Write down model names, and take a photo of Setting 3 and the DIP switches. Cut power, then check the cable and ports.
- Set the inverter to Li-ion or Lithium and brand 0. Set the JK app to CAN Luxpower 11 at 500 kbps.
- Set DIP 1000 on a single pack. Test the bus: about 60 ohms with power off, about 2.5 V per line with power on and idle.
- Power up battery first, then inverter. Wait two minutes for W000 to clear and a real SOC to show.
- Prove it under load and on charge, then write the settings on a note inside the battery box door.
- Brand 0 fails? Try brand 1, then 6, one at a time, with a BMS power cycle in between.
- No CAN port, or the link will not hold? Switch to voltage mode, set the volts from the datasheet, and run open-loop.
- Still stuck? Call EG4 support with model names, brand number, meter readings, and a photo of the DIP switches.
Sources
Checked on 20 November 2026. Unconfirmed items are labelled “not confirmed” in the text.
- EG4 6000XP User Manual v1.7.3, BMS port section. Pin 1 RS485 BMS_485 B, pin 2 RS485 BMS_485 A, pin 4 CAN BMS_CAN H, pin 5 CAN BMS_CAN L. Battery voltage range 46.4 to 60 V. Top charge 125 A. Top discharge 140 A. Setting 3 battery brand list: 0 EG4, 2 Pylon, 6 LuxPower, 8 Dyness. Fault 19 bus voltage too high, check PV not above 480 Vdc.
- EG4 18kPV User Manual. Battery Type Lithium, 0 for EG4 under Lithium Batteries. Advanced settings password 00000. Cut-off SOC 20 percent for EG4 batteries.
- EG4 field guide. W000 communication failure with battery. W027 battery open under 40 V. W026 battery voltage low. W004 battery fault.
- DIY Solar Forum field reports. JK PB V15 to 6000XP closed-loop, inverter battery type 0, JK CAN protocol 11 Luxpower. JK BMS firmware v14.24 to Luxpower 18kPV, Lux CAN, battery 0.
- YamBMS project notes. 6000XP Lithium 2 and Lithium 6, CAN PYLON V1 and LuxPower; 18kPV Lithium 6, CAN LuxPower.
- ISO 11898-2 CAN standard (PCBCool, Apex Control, SCADA Protocols). Idle 2.5 V per line. Dominant 3.5 V / 1.5 V. 120 ohm per end, about 60 ohms measured.
- JK BMS community reports. JK Inverter BMS, Luxpower CAN 11, 500 kbps. Field-reported. JK papers conflict on CAN-H/L pins 4/5; not confirmed. V19 parallel-bank reports; not confirmed.
- This site: EG4 6000XP & 18kPV battery communication pinout, JK BMS to Deye hybrid inverter protocol, JK BMS to Growatt SPF 5000 ES CAN setup, EG4 6000XP and 18kPV voltage mode fallback, Brand Pairings hub.
Comments (0)