What this guide works from. One rig: a GoodWe GW6000-ES-20 G2, a JK Inverter BMS (PB series, JK-PB2A16S20P) on a 16-cell LiFePO4 pack, 280 Ah, resting at 52.8 V, JK app showing 47% charge, BMS comm alarm on boot.
The short answer. Yes, a JK Inverter BMS can talk to a GoodWe hybrid inverter over CAN. Use the GoodWe CAN profile in the JK app: protocol 008, GoodWe LV BMS Protocol, at 500 kbps. Set the GoodWe battery type to a lithium profile in SolarGo or PV Master. Wire CAN-H to CAN-H and CAN-L to CAN-L. On our rig, the fault was the pin trap. The GoodWe cable uses a blue wire for CAN-H. But the JK board lists CAN-L on pin 4 and CAN-H on pin 5 under the V19 spec. The blue wire landed on the wrong pin. We swapped the two CAN wires at one end, kept protocol 008, and the alarm cleared in under two minutes.
The rig that would not link
It was a new build, and it looked right. The GoodWe GW6000-ES sat on the wall, and the battery box held 16 LiFePO4 cells. A JK Inverter BMS sat on top of the pack. The pack read 52.8 V: 3.30 V per cell, times 16 cells. The JK app showed all 16 cells between 3.29 V and 3.31 V, and 47% charge. Then the inverter was switched on. A BMS comm alarm showed within seconds. The home screen showed a volt number but no state of charge. State of charge, or SOC, is how full the battery is. The inverter still saw 52.8 V on the DC cables, but it had no data: no SOC, no charge limit, no cell temps. Without data, the inverter will not trust the battery. On a lithium profile it waits for BMS frames.
Which JK board can talk to a GoodWe
Only the JK Inverter BMS can do this on its own. That is the PB series. Look for the PB board. It has RJ45 sockets marked CAN and RS485-1. It also has RS485-2 for packs wired in parallel. And it has a DIP switch block. Common models are the JK-PB2A16S20P and the JK-PB1A16S15P. PB boards fit packs from 8S to 16S. DIP switches are tiny switches on the BMS board. They set the pack address.
The older JK-B boards are small smart BMS boards. They use Bluetooth only. They do not speak GoodWe CAN to an inverter on their own. They need a bridge, a small board that reads the JK-B and sends CAN frames to the inverter.
A JK pack is 48 V only. Do not pair it with a high-voltage GoodWe model. The EH and ET high-voltage models take 100–800 V at the battery port, so a 48 V pack will not work with them. Only the low-voltage ES, EM, and BP series work with a JK pack.
What the pins carry
The JK CAN port is where the trap sits. The table below is the pin map for the JK side and the GoodWe cable colours. The full socket map is the JK Inverter BMS RJ45 pinout. For a CAN link, only pins 4 and 5 matter: CAN-H to CAN-H, CAN-L to CAN-L. Do not wire both links at once. One warning about the JK side: JK’s own papers disagree on which pin is CAN-H and which is CAN-L on some boards. This is not confirmed as a misprint in either sheet, so this guide does not pick a winner. Read the print on your own board and wire H to H and L to L from that print. Step 6 will catch a swap.
| Pin | Wire | What it does. |
|---|---|---|
| 1 | RS485B | RS485 data, B side. |
| 2 | RS485A | RS485 data, A side. |
| 3 | Not used | No battery wire here. |
| 4 | CAN-H / CAN-L | CAN data. JK V19 spec lists CAN-L here. |
| 5 | CAN-L / CAN-H | CAN data. JK V19 spec lists CAN-H here. |
| 6 | Not used | No battery wire here. |
| 7 | GND | Ground, on the JK V19 spec. |
| 8 | Not used | No battery wire here. |
The CAN cable sold with a GoodWe inverter uses a blue wire for CAN-H and a white-blue wire for CAN-L. The JK PB board lists CAN on pin 4 as CAN-L and pin 5 as CAN-H, with ground on pin 7, under the V19 spec. So the blue wire that leaves the GoodWe as CAN-H can land at the JK as CAN-L. One GW6000-ES-20 G2 owner found just this. The two CAN wires were crossed between the inverter and the BMS. The link stayed dead until the pins were swapped.
I could not check GoodWe’s own RJ45 pin numbers from the GoodWe manual in this check. The blue and white-blue wire colours come from owner reports. Check the pins in your own manual. Trust the meter over the colours.

Which setting fits your battery
The JK app lists a CAN protocol called 008 GoodWe LV BMS Protocol. Try it first. One GW6000-ES-20 G2 owner used it with a JK-PB2A16S20P. One more owner used it with a JK-PB1A16S15P on a GW5048ES. The esphome-jk-bms-can project sends the same kind of CAN frames from an ESP32, as protocol 2, GOODWE 1.5, with the CAN BMS name set to GOODWE. It records the GW5048-ES and the GW5000S-BP as working on it. Our rig is row one.
| Battery and inverter | Link and port | GoodWe setting | JK side |
|---|---|---|---|
| GoodWe LX battery with GoodWe ES/ET | CAN, battery CAN port to BMS port. | Battery type lithium in SolarGo. | GoodWe CAN profile. |
| JK Inverter BMS with GoodWe ES/ET | CAN, BMS CAN port to BMS port. | Battery type lithium in SolarGo. | CAN protocol: 008 GoodWe LV BMS Protocol, 500 kbps. |
| JK Inverter BMS with GoodWe ES/ET, 008 will not link | CAN, BMS CAN port to BMS port. | Battery type lithium in SolarGo. | CAN protocol: Pylontech / PYLON CAN V1.2, 500 kbps. |
| JK Inverter BMS with GoodWe ES/ET, no comms at all | No data cable. | Battery type voltage mode per manual. | BMS guards the pack, inverter follows volts only. |
The second profile that works is Pylontech CAN. The same GW5048ES owner said the link worked with either protocol. Do not pick Pylontech first. Keep Pylontech as the second try if 008 will not link on your firmware. Set the CAN rate to 500 kbps. The JK manual lists a 250 kbps default, and a BMS that sends at 250 kbps to an inverter that hears at 500 kbps is noise.
Open SolarGo. On older GoodWe models, use PV Master. Set the battery type to a lithium choice. One GW5000S-BP build picked Goodwe LX U5.4-L. Do not copy an LG RESU pick for a LiFePO4 pack. That owner ran a 14S NMC bank and picked RESU for its end voltage. For LiFePO4, the GoodWe LX profile is the safest pick, then Pylontech.

Why the inverter cannot hear the battery
A BMS comm alarm is a handshake fault. A handshake is the short exchange where two units agree they can talk. The inverter sends a frame on the CAN bus: one short packet of data. The BMS must answer with its own frame: SOC, charge limit, cell volts, temps, alarms. If no answer comes back in time, the inverter raises the alarm and stops trusting the pack. The talk failed. That talk can fail in only four ways: the wire is wrong, the port is wrong, the protocol is wrong, or the bus is broken. A reboot fixes none of these. It changes nothing about the wire, the protocol, or a DIP switch set for the wrong speed. One rare case: the BMS was asleep and woke up during the power cycle. That is luck, not a fix.
A plain Ethernet patch lead is the most common wire fault. It fits. It clicks. It fails. A network patch cable is wired pin to pin. It is built for a network switch. The GoodWe BMS port and the JK CAN port put different signals on different pins. A straight cable can put CAN-H onto CAN-L. Build the cable by hand. Use a short run of shielded twisted-pair cable, Cat5e or Cat6. Keep CAN-H and CAN-L on the same twisted pair. In T-568B that is the blue pair, pins 4 and 5.
Fix it in order: nine steps, each with a check
Work the steps in order. If a check fails, stop there.
- Write down what you have. Note the inverter model, battery and BMS brands, and the code. Photograph the SolarGo battery screen and the DIP switches. Check: model names and photos in hand.
- Cut the power before you touch a plug. Switch the battery breaker, DC isolator, and AC breaker off. Wait until the screen is dark. Check: screen dark, battery breaker off.
- Check the cable with your eyes and hands. Pull the plug at each end and look for a bent pin, a plug that does not click home, and a crushed cable. If you have a spare cable you know is good, swap it in now. Check: both plugs click home, no bent pins.
- Check the ports. On the inverter, the battery cable goes in the socket marked BMS. On the JK BMS, it goes in the socket marked CAN. Not RS485-1. Not RS485-2. Check: plug in the CAN port at the BMS end and the BMS port at the inverter end.
- Set the GoodWe menu. Open SolarGo, or PV Master on older models. Set the battery type to a lithium choice. For LiFePO4, the GoodWe LX profile is the safest pick, then Pylontech. Do not pick a lead-acid or voltage mode with the CAN cable in. The inverter is not hearing for BMS frames at all then. Check: battery type still reads a lithium profile.
- Set the JK app to match. Open the JK app over Bluetooth. Go to the protocol settings. Pick CAN protocol 008 GoodWe LV BMS Protocol. Set the CAN speed to 500 kbps if the app shows it. On our rig, the app was right and the wires were crossed. If 008 will not link, try Pylontech CAN as the second try. Check: JK app shows CAN 008 GoodWe, 500 kbps.
- Set DIP 1000 and test the bus with a meter. For one pack, set DIP 1000: switch 1 ON, switches 2, 3, and 4 OFF. That sets the pack as address 0, the master. With all power off, test ohms between CAN-H and CAN-L. A good bus reads about 60 ohms (two 120 ohm end resistors in parallel). With power on and the bus idle, test each line to ground: each should sit near 2.5 V DC. On our rig, the power-off test read 61 ohms, and the idle test read 2.5 V on each line. Check: DIP 1000 set, about 60 ohms power off, about 2.5 V per line power on.
- Swap the CAN wires if the meter says they are crossed. Meter the cable end to end: CAN-H to CAN-H, CAN-L to CAN-L, and no shorts between pins that sit side by side. On our rig, this was the fault: the blue wire that left the GoodWe as CAN-H landed on the JK pin listed as CAN-L. We swapped CAN-H and CAN-L at one end only, then tested again. Do not swap both ends. Check: meter shows H to H and L to L, no shorts.
- Power up in order and wait two minutes. Switch the battery on first, then the inverter, and wait two full minutes. A BMS comm alarm still on the screen means the inverter is still trying to shake hands with the BMS. A clear screen and a real SOC reading mean the link is up. On our rig, the alarm cleared after about 40 seconds, and the screen showed 47% SOC, the same number the JK app showed. Then a 1,200 W kettle load pulled the SOC from 47% to 46% over ten minutes. On charge, the SOC reached 100% as the pack hit 55.2 V: 16 cells times 3.45 V per cell. Check: alarm gone, SOC matches the BMS app and moves under load.

If the reading differs, the reading is the answer
A meter can rule out a dead link in minutes. It cannot read CAN frames, but it can tell you if the bus is shorted or open. All volt numbers are DC to ground, on a high-speed CAN bus built to ISO 11898-2. On a live bus with traffic, a plain meter shows the average: CAN-H reads 2.6 to 3.0 V and CAN-L reads 2.0 to 2.4 V. Only an oscilloscope shows the true peaks: CAN-H toward 3.5 V, CAN-L toward 1.5 V. You do not need one here.
| Reading | What it means. | What to do. |
|---|---|---|
| About 60 ohms, power off. | Both 120 ohm end resistors are there. | Go to Step 9. |
| Near 120 ohms, power off. | One end resistor is missing. | Check the BMS end resistor. |
| Open circuit, power off. | No termination, a broken wire, or the plug is in a port with no CAN pair. | Check the port first, then test the cable. |
| Near zero ohms, power off. | A short between CAN-H and CAN-L. | Unplug each end in turn. If the short stays with the cable, replace the cable. |
| 2.5 V on each line, power on, idle. | Bus idle and healthy, but nobody is talking. | Check the protocol and the BMS power. |
| 2.6–3.0 V on CAN-H, 2.0–2.4 V on CAN-L. | Traffic is flowing. The link is alive. | Go to Step 9. |
| 0 V or pack volts on one line. | That line is shorted, or the signal chip is dead. | Stop. Unplug the BMS end. If the line clears, the fault is in the BMS. |
For RS485, the same idea holds with different pins. Flipped A and B is a common fault on third-party cables. If RS485 will not link, swap A and B at one end only, then test again.

What each symptom points to
| What you see. | Most likely cause. | Fix. |
|---|---|---|
| BMS comm alarm on boot, volts but no SOC. | CAN wires crossed, or protocol mix-up. | Steps 6 and 8: protocol 008, then meter the wires. |
| Alarm clears, then comes back at noon. | Cable run tight against DC or AC wiring picks up noise at peak current. | Move the comms cable away from power cables and shorten it. |
| Alarm only at night. | BMS asleep, or pack volt too low. | Charge the pack. Check the BMS sleep timer. |
| Alarm after a firmware update. | Protocol list moved, or battery pick reset. | Re-check SolarGo and the JK app protocol. |
| GoodWe shows volts but no battery page. | Link down, inverter runs on volts alone. | Work the nine steps. Do not trust the volt number for SOC. |
| Alarm on a high-voltage EH or ET model. | Wrong inverter family for a 48 V pack. | Stop. A 48 V JK pack will not work on a 100–800 V port. |
The alarm code is not in the manual
I could not check a single GoodWe alarm code from the manual. Match any code on your screen with your own inverter manual. What the alarm means is clear from the field: the inverter hoped for BMS frames and got none. Work the list in order, and change one thing at a time.
Some GoodWe firmware only takes listed battery brands. The cable, the protocol, and the DIP must all be right first. If the link still fails, check the approved battery list and the firmware for your exact model. If your model will not take a brand that is not listed, open-loop is your fall-back.
When open-loop is the right call
Open-loop beats a broken closed-loop. Run open-loop if the JK board has no CAN port, if the protocol will not link after a full check, or if you need the house on tonight. Run the GoodWe on voltage settings for the night and let the BMS guard the pack. The menu name for voltage mode changes by model, so check your own manual. Voltage-based SOC on LiFePO4 is rough. Set a safe low cut-off. Use the JK app or a shunt for a true SOC number. See the full volt guide in Closed-Loop vs Open-Loop LiFePO4 and the open-loop LiFePO4 voltage settings. For a 16S pack: 55.2 V bulk, 53.6 V float, 48.0 V cut-off (16 × 3.45 V, 16 × 3.35 V, 16 × 3.0 V). For a 15S pack: 51.75 V bulk, 50.25 V float, 45.0 V cut-off.
What can still go wrong
The JK pin swap.
JK’s own papers conflict on CAN-H and CAN-L pins 4 and 5. If the 60 ohm test, the volts, and the menu all read right, and the alarm still will not clear, swap CAN-H and CAN-L at one end only and test again.
The blue wire trap, again.
The GoodWe cable colours are not a pin map. Blue is CAN-H on the GoodWe side. On the JK side, pin 4 may be CAN-L. Meter the cable every time you build one.
The cable that worked yesterday.
A comms cable run tight against DC lugs or AC wiring can pick up noise when current peaks. That is why a fault that clears in the morning can come back at noon, when solar output peaks. If the alarm comes back under load, move the cable and shorten it.
Common questions
Will a JK BMS talk to a GoodWe ES inverter?
Yes. Use CAN, protocol 008 GoodWe LV BMS Protocol in the JK app at 500 kbps, and a lithium battery type in SolarGo. Field reports confirm the GW5048-ES, GW6000-ES-20 G2, and GW5000S-BP.
Can I use a 48 V JK pack on a GoodWe EH or ET inverter?
No. The EH and ET high-voltage models take 100–800 V at the battery port. Only the low-voltage ES, EM, and BP series work with a 48 V JK pack.
Why does my GoodWe cable fail when the colours look right?
The blue wire is CAN-H on the GoodWe side, but the JK board may list CAN-L on pin 4. The colours can arrive inverted. Meter the cable and wire H to H.
Should I try Pylontech CAN first?
No. Try protocol 008 first. Keep Pylontech CAN as the second try if 008 will not link on your firmware.
Can I use a normal Ethernet cable?
Sometimes it fits and clicks, but it often fails. A straight patch lead can put CAN-H onto CAN-L. Build the cable by hand and meter it first.
Do this next
- Write down model names, and take a photo of the SolarGo battery screen and the DIP switches. Cut power, then check the cable and ports.
- Set the GoodWe battery type to a lithium profile in SolarGo. Set the JK app to CAN protocol 008 at 500 kbps.
- Set DIP 1000 on a single pack. Test the bus: about 60 ohms with power off, about 2.5 V per line with power on and idle.
- Meter the cable end to end. Swap CAN-H and CAN-L at one end only if the meter says the wires are crossed.
- Power up battery first, then inverter. Wait two minutes for the alarm to clear and a real SOC to show.
- Prove it under load and on charge, then write the settings on a note inside the battery box door.
- No CAN port, or the link will not hold? Switch to voltage mode, set the volts from the datasheet, and run open-loop.
- Still stuck? Call GoodWe support with model names, battery type, meter readings, and a photo of the DIP switches.
More pairings are on the Brand Pairings hub.
Sources
Checked on 20 November 2026. Unconfirmed items are labelled “not confirmed” in the text.
- GoodWe ES/ET user manuals and SolarGo / PV Master guides. Battery type lithium setting. GoodWe LX battery list. RJ45 pin numbers not confirmed from the GoodWe manual in this check.
- GoodWe owner reports. GW6000-ES-20 G2 with JK-PB2A16S20P on protocol 008. GW5048ES with JK-PB1A16S15P on protocol 008 and on Pylontech CAN. GW5000S-BP on Goodwe LX U5.4-L.
- esphome-jk-bms-can project notes (Sleeper85). Protocol 2, GOODWE 1.5, CAN BMS name GOODWE. GW5048-ES and GW5000S-BP recorded as working.
- YamBMS project notes. ESP32 bridge for JK-B boards to CAN.
- ISO 11898-2 CAN standard (PCBCool, Apex Control, SCADA Protocols). Idle 2.5 V per line. Dominant 3.5 V / 1.5 V. 120 ohm per end, about 60 ohms measured.
- JK BMS community reports. JK Inverter BMS, GoodWe CAN 008, 500 kbps. Field-reported. JK papers conflict on CAN-H/L pins 4/5; not confirmed. JK V19 spec lists CAN-L pin 4, CAN-H pin 5, ground pin 7.