What this guide works from. One rig: a Deye 5 kW hybrid inverter, a Seplos V2 BMS on a 16-cell LiFePO4 pack, 280 Ah, resting at 52.6 V, and a Raspberry Pi 4 running Solar Assistant. The BMS and the inverter will not talk. The inverter screen shows no SOC.
The short answer. Yes, Solar Assistant can bridge them, but not by faking a battery. Solar Assistant is a small computer. It reads the BMS on one cable and the inverter on a second cable. It shows true cell volts, amps, and SOC on its own screen. SOC means state of charge, how full the battery is. The inverter keeps its own volt settings. Solar Assistant does not send Pylontech CAN frames to the inverter. That job belongs to an ESP32 protocol bridge, not to Solar Assistant. If you need the inverter screen itself to show BMS SOC, use a protocol bridge. If you need true SOC on a screen and rules that act on it, Solar Assistant is the right tool.
The rig that would not link
It was a new build, and each part worked on its own. The Deye 5 kW hybrid sat on the wall. The battery box held 16 LiFePO4 cells with a Seplos V2 BMS. The pack read 52.6 V at rest: 3.29 V per cell, times 16 cells. The BMS app showed all 16 cells between 3.28 V and 3.30 V, and 58% charge. The inverter ran the house fine, but on volts alone. It had no SOC, no charge limit from the BMS, and no cell temps. The BMS knew the pack. The inverter did not.
The owner had tried the direct link first. It failed because the Seplos V2 and this Deye build would not agree on the talk rules. No menu change fixed it. That is the case for a bridge: two good parts that will not talk to each other.

What Solar Assistant is, and what it is not
Solar Assistant is software from solar-assistant.io. You flash it onto a small board and leave it running next to your inverter. Its dashboard runs in a web browser. It shows live solar, battery, grid, and load numbers, plus history. The boards that work are the Orange Pi 3 LTS, the Raspberry Pi 5 or 4, and the Raspberry Pi 3 or Zero 2 W. A Pi 1, 2, or first Zero does not work.
There are two kinds of bridge, and people buy the wrong one. A monitoring bridge is Solar Assistant. It links to the inverter through its normal port for checks and settings: USB, RS232, or RS485. It also links to the BMS through a second USB cable. The inverter keeps its own battery setting. Solar Assistant adds true BMS data on screen, remote setting changes, and rules that run off real SOC. A protocol bridge is different: an ESP32 board that runs YamBMS or esphome-jk-bms-can. It sends Pylontech CAN frames to the inverter's BMS port. That is the only way to put BMS SOC on the inverter screen when the real BMS cannot talk to the inverter.
On our rig, the choice was clear. The owner wanted true SOC on a phone, and rules that stop the drain at low SOC. The inverter screen could stay on volts. So Solar Assistant was the right bridge. A protocol bridge would have been the pick if the inverter screen had to show SOC.
The three ways Solar Assistant reads a battery
On the setup page you pick one battery source from the official list. The table below is the whole choice. Pick the top row you can.
| Battery source | What it reads | When to pick it |
|---|---|---|
| Use inverter values | Whatever SOC and volts the inverter reports | Your inverter already has a working BMS link |
| USB cable to a real BMS | Cell volts, amps, SOC and temps, straight from the BMS | First choice when your BMS is listed |
| Emulated BMS | No BMS at all; Solar Assistant counts power in and out and works out SOC itself | Fallback when no BMS cable exists |
"Use inverter values" needs a warning. If your inverter has no BMS cable, its SOC comes from volts. On LiFePO4, that number is rough. LiFePO4 is the lithium iron type used in most home batteries. Its discharge curve is nearly flat in the middle. So volts barely move as the battery drains. Solar Assistant's own docs say this about Voltronic inverters with no BMS cable. On our rig, the inverter said 41% while the BMS said 58%. The inverter was guessing from volts. The BMS was counting amps. The BMS was right.
The Emulated BMS counts amp-hours in and out. Amp-hours are a count of charge moved. It turns that count into an SOC. Solar Assistant's docs rank it below a Victron BMS or shunt, but above the inverter's volt reading. A count drifts. Small errors add up. The count only re-syncs when the battery hits full or empty. On our rig, the Emulated BMS was not needed. The Seplos V2 is on the list, so the real BMS cable was the pick.

Why the bridge works when the direct link does not
A direct link needs both ends to agree on the same talk rules. Same plug, same speed, same frame shape, same brand code. If one side sends Pylontech CAN and the other side waits for a different brand code, nothing lands. The inverter shows a comms fault, or it shows nothing at all. The fault is not in the wire. The fault is in the agreement.
Solar Assistant skips the agreement. It does not ask the two sides to talk to each other. It talks to each side on its own terms. It reads the inverter through the inverter's own monitor port. It reads the BMS through the BMS's own port. Each side speaks its own language to the Pi. The Pi puts both sets of numbers on one screen. That is why it works where a direct link fails. It never joins the two wires.
Wiring it up: JK, Seplos and Pylontech
Start from the official battery setup page, not a forum pinout. The steps below come from that page and its per-BMS guides, read in November 2026.
Original JK BMS (older JK-B boards). You need two parts Solar Assistant does not sell: a JK BMS RS485 module and a USB RS485 adapter. Use an FTDI chip, not TTL. Pick the "USB JK RS485" protocol. Plug the cable in and click connect. JK Inverter BMS (newer JK PB range). Use a Seplos RS485 BMS cable. You can make it at home. RS485B is on pin 1. RS485A is on pin 2. The ports on the right let Solar Assistant listen in on the link between BMS units in parallel. The port on the left needs the BMS set to the "000 – 4G-GPS" protocol in the official JK PC software.
Seplos V1/V2. Seplos V1 and V2 are on the official list under "USB Serial RS232/RS485", using the Seplos RS485 port. On our rig, the V2 linked first time on that port. Seplos V3 is the gap. I could not find a Seplos V3 entry on the official battery setup page I read. Forum reports clash about whether it works. Do not buy Solar Assistant for a Seplos V3 pack on that hope. Check the list first.
Pylontech and Pytes. Pylontech shows up twice on the list: the RS232 console port and the CAN port. The console port gives full battery data, even while the battery's CAN or RS485 port stays wired to the inverter. Both links live at once.
You also need a microSD card, a case with air flow, and a power supply that stays on. A 9–60 V DC to 5 V supply wired to the battery posts keeps the Pi alive when the grid drops out. A mains USB-C supply dies with the grid. A field report on PowerForum traces random Solar Assistant dropouts to a weak Raspberry Pi power supply. The fix was the official Pi supply at 5.1 V. A Pi that sags under load drops both links at once. Use the official supply, or a known-good 5 V 3 A supply.
Deye and Sunsynk: sharing one BMS port
Deye, Sunsynk, and Sol-Ark inverters have a BMS port that does two jobs at once. The battery CAN cable stays in the port, and Solar Assistant reads the inverter through the RS485 pins at the same time. Its cable uses pins 1 to 3 only. Pin 1 is RS485B. Pin 2 is RS485A.
Test it first: unplug the battery CAN cable for a short time and plug the Solar Assistant RS485 cable in. Click "Disconnect", then "Connect" in Solar Assistant. If it reads the inverter, the test passed. Then put the battery CAN cable back.
For day-to-day use, get an RJ45 splitter. Solar Assistant sells one made for Deye, Sunsynk, and Sol-Ark. Or crimp both sets of wires into one RJ45 plug with the RS485 self-crimp USB cable. One warning: a plain splitter can feed the RS485 pins into the battery, and the battery may use those pins for a different job. That can break the link. The battery cable should carry the CAN pins only.
The hardware you need, in one table
Buy the right parts once. The wrong adapter is the most common waste of cash here. A cheap adapter can cost you a whole weekend. The table lists each part. It gives the pick that works. Check each row before you order. If a part is not on the list, do not guess. Ask on the Solar Assistant forum first. One wrong part can look like a dead BMS.
| Part | Pick this | Why it matters |
|---|---|---|
| Board | Raspberry Pi 4 or 5, or Orange Pi 3 LTS | Pi 1, 2, or first Zero do not work |
| Storage | microSD card, flashed with the Solar Assistant image | The Pi boots from this card |
| Power | Official Pi supply at 5.1 V, or DC 5 V from the battery posts | A weak supply drops both links at once |
| Inverter cable | USB, RS232, or RS485 to suit your inverter model | One cable per inverter, no sharing |
| BMS cable | USB RS485 adapter, FTDI chip, not TTL | Cheap CH340 adapters have failed in field reports |
Field reports warn that cheap CH340-chip USB to RS485 adapters have failed where FTDI-chip adapters worked. Solar Assistant's own JK guide tells you to use FTDI. It warns the adapter must be a real RS485 adapter, not a TTL one. A cheap adapter can look like a dead BMS. It can waste hours of your time.
Set it up in order: nine steps, each with a check
Work the steps in order. If a check fails, stop there.
- Check the supported list first. Find your BMS and your inverter on the Solar Assistant supported-device list. Check: both names are on the list.
- Try the direct link first. Wire the BMS to the inverter on its own cable. Set the protocol the JK BMS to Deye inverter protocol guide gives for your pair. Check: if the inverter shows BMS SOC, stop here. You do not need a bridge.
- Flash the card and boot the Pi. Flash the Solar Assistant image to the microSD card with Raspberry Pi Imager and its custom image option. Put the card in the board. Power it on. Check: the Pi makes its own WiFi spot named "SolarAssistant", and the dashboard loads.
- Join the Pi to your home WiFi. Join the hotspot and link the Pi to your home WiFi. Run Ethernet if you can. Check: the dashboard loads over your home network, not just the hotspot.
- Wire the inverter cable first. Plug the Pi to the inverter on USB, RS232, or RS485 to suit your model. On the setup page, pick your inverter brand and model. Click connect. Check: the dashboard shows solar watts, load watts, and grid watts.
- Wire the BMS cable second. Plug the USB RS485 cable into the BMS port the official guide names for your BMS. Pick the battery source and the matching USB cable. Click connect. Check: the dashboard shows cell volts, pack amps, temps, and SOC from the BMS.
- Set the inverter volts from the datasheet. The inverter stays on its user-set or volt battery setting. Set the charge volts from the battery datasheet. Use the same steps as the LiFePO4 open-loop voltage settings 15S/16S guide. For our 16S pack: bulk 55.2 V, float 53.6 V, cut-off 48.0 V. For a 15S pack: 51.75 V, 50.25 V, 45.0 V. Equalization off, temp comp 0 mV/°C. Check: bulk, float, and cut-off match the datasheet, and equalization is off.
- Compare the two SOC numbers for a full day. Watch the SOC at dawn, at noon, and at night. On our rig, the BMS said 58% at noon and the inverter said 41%. Check: if the two SOC numbers clash, trust the BMS.
- Set one rule, then test it. Start with one rule only: stop the drain at low SOC. When the BMS SOC falls to 20%, switch the output priority to utility. Check: the rule fires at 20% SOC.
If the reading differs, the reading is the answer
A wrong reading is a clue, not a dead end. Read the row that matches what you see. Each row names the most likely cause. Each row gives the fix. Work one row at a time. Change one thing, then test again. Do not change the cable and the settings in the same step. You will not know which change fixed it. Give each change five minutes to settle. A link that needs two minutes to wake up looks dead at thirty seconds.
| What you see | Most likely cause | Fix |
|---|---|---|
| Dashboard shows no inverter | USB cable, Pi power, or wrong model pick | Try a short shielded USB cable; test with the maker's PC software |
| Dashboard shows no BMS | Wrong port, wrong protocol, or CH340 adapter | Use an FTDI adapter; check the port the guide names |
| BMS SOC and inverter SOC clash by 10% or more | Inverter guesses from volts; BMS counts amps | Trust the BMS; set inverter volts from the datasheet |
| Pi drops both links at once | Weak Pi power supply | Use the official 5.1 V supply or a DC supply from the battery posts |
| Inverter shows a BMS comms fault | Direct link is down; Solar Assistant cannot clear it | Fix the direct link first — see the Deye F58 fix |
| SOC drifts over weeks | Count never re-syncs without a full charge | Run a full charge weekly; the count resets at 100% |
On our rig, the first fault was the second row. The dashboard showed no BMS. The adapter was a cheap CH340 chip. A swap to an FTDI adapter fixed it in one minute. The BMS data then showed at once. That is how fast the right part can fix a dead link. If the fault is the fifth row, stop. Solar Assistant cannot clear a comms fault. Fix the direct link first. Then come back to the bridge.
SOC accuracy: counting beats reading volts, and a shunt beats both
Volts-based SOC is what an inverter does with no BMS link. It is the weakest way to read SOC on LiFePO4. Most of the usable range sits within a volt or two. So the inverter's guess swings with load and heat. It is fine as a rough fuel gauge. It is risky as a control signal.
Coulomb counting is better. That is the Emulated BMS, and it is what most BMS units do inside too. It counts amps in and out against pack size. But it drifts unless the pack hits full charge often. A full charge lets the count re-sync to 100%.
A shunt is the most true of the three for SOC alone. Solar Assistant works with a Victron BMV or SmartShunt over VE.Direct. VE.Direct is Victron's own data link. The official docs rank a shunt above the Emulated BMS. If SOC truth is why you buy hardware, a shunt beats the Emulated BMS. But a shunt still does not show cell volts. Only a real BMS cable does that.

What it cannot fix
Solar Assistant cannot fix a BMS that will not speak. If your BMS has no working port, no known protocol, and no entry on the list, a Pi and a cable do not make data appear.
It cannot fix a broken direct BMS link on its own. If your inverter shows a BMS comms fault, such as Deye F58, Solar Assistant will not clear it. The inverter still waits for frames on its own BMS port. Read the JK BMS to Deye inverter protocol guide for the direct-link fix first.
It cannot guard a pack the BMS has already cut off, or fix wrong inverter settings. If the BMS opens its contactor on a cell fault, Solar Assistant can tell you which cell did it. It cannot close the contactor. A contactor is a big switch inside the battery. Set volts from your battery's datasheet. If the Pi dies or loses power, the inverter keeps the settings stored in it. So set those well. They are your safety net.
What can still go wrong
The Seplos V3 gap.
Seplos V3 has no entry I could find on the official battery setup page. Forum reports clash. Do not buy on hope. Check the list first. This is not confirmed either way.
The Deye splitter trap.
A plain RJ45 splitter can feed RS485 pins into the battery. The battery may use those pins for a different job. That can break the link. Use the splitter Solar Assistant sells, or crimp both sets of wires into one plug with the battery cable carrying CAN pins only.
The weak supply.
A Pi that sags under load drops both links at once. The dashboard goes dark, and the rules stop. The inverter falls back to volts. That is safe, but the house runs blind. Use the official supply.
The hotspot address.
The dashboard address 10.10.100.10 is one I could not fully check. This is not confirmed. Use Ethernet if the hotspot will not load.
Common questions
Can Solar Assistant fake a BMS to my inverter?
No. It reads the BMS and the inverter side by side. It sends no CAN frames to the inverter.
Will it clear a Deye F58 fault?
No. F58 means the inverter cannot hear the BMS on its own BMS port. Solar Assistant reads the inverter through a different port. Fix the direct link first.
Do I still need the direct BMS cable?
Yes, if it works. Keep it. Solar Assistant is a second reader, not a swap. If the direct link works, the inverter gets live SOC and charge limits.
Which adapter chip should I buy?
FTDI. Solar Assistant's own JK guide says so. Cheap CH340-chip adapters have failed in field reports where FTDI adapters worked.
Do this next
- Check your BMS and inverter against the supported list before you spend cash.
- Try the direct BMS link first. If it works, stop.
- If it will not link, order the board, an FTDI USB RS485 adapter, and the BMS cable the guide names.
- Flash the image, wire the inverter first and the BMS second, and pick the real BMS protocol.
- Set the inverter volts from the datasheet: 16S bulk 55.2 V, float 53.6 V, cut-off 48.0 V.
- Compare BMS and inverter SOC for a full day. Trust the BMS when they clash.
- Set one rule only to start: stop the drain at 20% SOC, with the inverter volt cut-off as backstop.
Sources
Checked on 20 November 2026. Unconfirmed items are labelled "not confirmed" in the text.
- Solar Assistant official site, solar-assistant.io, battery setup page and per-BMS guides. Boards, three battery sources, FTDI advice, Deye RS485 pins 1 and 2.
- Solar Assistant JK BMS guide. Original JK needs the RS485 module; JK PB uses a Seplos RS485 cable, pins 1 and 2, left port "000 – 4G-GPS".
- Solar Assistant official docs, inverter guides. Voltronic inverters with no BMS cable report volts-based SOC.
- PowerForum field reports. CH340 adapters failed where FTDI worked; weak Pi supply caused dropouts, fixed with the official 5.1 V supply.
- DIY Solar Power Forum, Solar Assistant threads. Emulated BMS ranked below a Victron shunt, above inverter volts.
- Victron SmartShunt docs, via Solar Assistant docs. VE.Direct link, shunt ranked above Emulated BMS for SOC.
- This site: JK BMS to Deye inverter protocol, Deye F58 fix, open-loop LiFePO4 voltage settings, Seplos V2 vs V3 pinout.
Comments (0)