What this guide works from. One rig: a Seplos V3 Mason 16S 200A pack with a 2A active balancer, a Deye SUN-8K hybrid inverter, the pack resting at 52.8 V, BatteryStudio showing 55% charge, and the Deye screen showing no battery at first.
The short answer. Do not plug a V2 cable into a V3 pack. Do not plug a V3 cable into a V2 pack either. The plugs look the same. The sockets look the same. But the two versions do not use the same pins in the same way, and they do not talk the same way. V2 is the older 10E board, sold before December 2023. It talks with the old Seplos ASCII rules through a program called BatteryMonitor. V3 is BMS 3.0, sold after December 2023. It talks with Modbus RTU through a program called BatteryStudio. On our rig, the fault was the CAN pair: the book said pin 4 was CAN-L, but the live board had CAN-H on pin 4. We swapped the pair at one end only, and the Deye showed 55% SOC within two minutes.
The rig that would not link
It was a new build, and it looked right. The Deye 8 kW sat on the wall, and the Seplos Mason pack sat below it. The pack read 52.8 V: 3.30 V per cell, times 16 cells. BatteryStudio showed all 16 cells between 3.29 V and 3.31 V, and 55% charge. Then the inverter was switched on. The Deye home screen showed pack volts, but no SOC and no battery data. State of charge, or SOC, is how full the battery is.
How to tell V2 from V3
Start with the label, not the cable drawer. A V2 board is often marked 10E. The sticker on top of the board may read 1101-48200-10E. Fogstar puts the split at December 2023. A V3 board is marked BMS 3.0. It is often a 16S 200A board with a 2A active balancer. If the sticker is hidden, the software gives it away. V2 works with BatteryMonitor 2.x. V3 works with BatteryStudio. Seplos books state that BMS 2.0 and BMS 3.0 cannot run side by side in one bank. So a V2 pack and a V3 pack do not belong in the same bank, even if both are 16S LiFePO4 at 51.2 V nominal. Both boards give CAN at 500 kbps for the inverter, Pylontech rules by default. Both give RS485 at 19200 baud for checks on a PC. V2 answers the old ASCII notes that start with ~2000 at 19200 baud. V3 ignores those notes. It speaks Modbus RTU at 19200, 8N1, on RS485-1. So a silent V3 pack often means the software is still speaking V2. What changed is how the board talks, how it is addressed, and how its ports are laid out. DIP switches set the address on both boards. On one tested V3 Mason pack, all switches off gave address 0. Check your own pack in BatteryStudio before you trust that. On a bare V2 board, CAN and RS485 often share one RJ45 socket. On a finished V3 Mason pack, the front panel has sockets marked CAN/RS485, RS485-1, and RS485-2. RS485-1 is the port the V3 Modbus work was tested on. RS485-2 is the link port for packs in parallel. Use the port your book names first.

What the pins carry
The RS485 pins you can trust are pin 1 for B- and pin 2 for A+. Ground sits on pins 3 and 6. The CAN pins are the problem. Some Seplos books print CAN-L on pin 4 and CAN-H on pin 5. People who tested live boards found the reverse. Pin 4 is CAN-H and pin 5 is CAN-L. Build a cable with only the wires you need. The table below is the newer-spec layout, the one with pin 4 CAN-H and pin 5 CAN-L. The older print is in the next section. The Deye side of the link is the Deye & Sunsynk BMS port pinout.
| Pin | Wire | What it does. |
|---|---|---|
| 1 | RS485-B | RS485 data, B- side. |
| 2 | RS485-A | RS485 data, A+ side. |
| 3 | GND | Signal ground. |
| 4 | CAN-H | CAN data, high line. Newer spec. |
| 5 | CAN-L | CAN data, low line. Newer spec. |
| 6 | GND | Signal ground. |
| 7 | RS485-A | RS485 data, A+ side, mirrored. |
| 8 | RS485-B | RS485 data, B- side, mirrored. |
The pin job is steady across the V2 books, the V3 pack specs, the ESPHome Seplos project, and live Home Assistant work on a V3 Mason pack. Pin 1 is RS485-B. It is also written B- or D-. Pin 2 is RS485-A. It is also written A+ or D+. Pins 3 and 6 are ground. It is mirrored on the far side of the socket. Pin 8 is also B-. Pin 7 is also A+. One installer joined pin 1 to pin 8 and pin 2 to pin 7 for a firmer grip on thin wires, and it worked. The mirror is why that works. Pins 4 and 5 are not linked on a socket made just for RS485. On a shared socket they carry CAN.

Which setting fits your battery
Pick the bus first, then the port, then the profile. If your inverter speaks Pylontech CAN, use the CAN port, pins 4 and 5, and set the Pylontech CAN profile on the inverter. If it speaks Pylontech RS485, use the RS485 port, pins 1 and 2, and set the Pylontech RS485 profile. If your inverter is a Deye, use the CAN port with Lithium Mode 00. The profile and the port have to agree, and the inverter setting has to agree with both. CAN runs at 500 kbps on the Pylontech profile. RS485 runs at 19200 baud for Seplos checks on a PC. A V3 table lists Pylontech RS485 at 9600, a different link from Seplos checks at 19200. The full Deye pairing is the JK BMS to Deye hybrid inverter protocol.
| Battery and inverter | Link and port | Inverter setting | BMS side |
|---|---|---|---|
| Seplos V3 Mason with Deye 8 kW | CAN, CAN/RS485 socket pins 4 and 5. | Lithium Mode 00. | Pylontech CAN, 500 kbps. |
| Seplos V3 Mason with Growatt SPF 5000 ES | CAN, CAN/RS485 socket pins 4 and 5. | Program 05 LI, Program 36 L52. | Pylontech CAN, 500 kbps. |
| Seplos V3 Mason with Victron Cerbo GX | CAN, CAN/RS485 socket pins 4 and 5. | VE.Can, Pylontech CAN. | Pylontech CAN, 500 kbps. |
| Seplos V2 or V3 on a PC | RS485, RS485-1 pins 1 and 2. | BatteryMonitor (V2) or BatteryStudio (V3). | ASCII (V2) or Modbus RTU (V3), 19200 baud. |
Why the pin order matters
A dead Seplos link is a handshake fault. A handshake is the short exchange where two units agree they can talk. The inverter sends a frame on the CAN bus: one short packet of data. The BMS must answer with its own frame: SOC, charge limit, cell volts, temps, alarms. If no answer comes back in time, the inverter shows no battery and stops trusting the pack. The talk failed. That talk can fail in only four ways: the wire is wrong, the port is wrong, the rules are wrong, or the bus is broken. A reboot fixes none of these. It changes nothing about the wire, the software, or a CAN pair wired to the wrong print.
CAN works as a pair. CAN-H and CAN-L are two wires that move in step, one up and one down. The twist in the pair cancels noise from near wires. That is why the two CAN wires must sit on the same twisted pair in the cable, most often the blue pair in T-568B, pins 4 and 5. If CAN-H and CAN-L are swapped, each line still sits near 2.5 V at rest. The meter looks fine, but no frame gets through. The bus is dead, and the volts lie to you. A swap will not short anything. Both lines sit near 2.5 V at rest. But the link will not work. Test it before you trust either print.
The short risk here is not a Seplos pin that carries pack power. I checked the books and field notes for a power pin on the Seplos RJ45 sockets. I found none. No checked Seplos source puts 12 V, 5 V, or 48 V on any RJ45 pin on V2 or V3. The short risk is the far end. A stock Ethernet patch cable joins all eight pins, pin to pin. On a shared Seplos socket that joins CAN-H and CAN-L to what the far end puts on pins 4 and 5. It joins RS485-A and RS485-B to what the far end puts on pins 1, 2, 7, and 8. On an inverter whose BMS port puts a different signal on pins 3, 6, 7, or 8, the same cable joins buses that were never meant to meet. Joining a CAN pair to an RS485 pair can hold both buses down. And the far end is not always a BMS port. An inverter RJ45 socket can carry RS232, a dry-contact signal, or a power feed.
Fix it in order: nine steps, each with a check
Work the steps in order. If a check fails, stop there.
- Read the label and pick the software. Find the version on the label. Write it on the case. Pick the matching software. BatteryMonitor for V2. BatteryStudio for V3. Check: version written down, right software open.
- Read the pack on RS485 first. Plug the PC lead into RS485-1, open the right software, and read the cells at 19200 baud. Check: software shows live cell volts.
- Cut the power before you touch a plug. Switch the battery breaker, DC isolator, and AC breaker off. Wait until the inverter screen is dark. Check: screen dark, battery breaker off.
- Build the cable for one link only. For CAN to the inverter you need three wires at most: CAN-H, CAN-L, and ground. For RS485 you need three: A+, B-, and ground. Spare wires stay unlinked. Cut them back inside the plug. Use shielded twisted-pair cable. Put CAN-H and CAN-L on the blue pair, pins 4 and 5. Put RS485 A+ and B- on the orange pair, pins 1 and 2. Check: only the wires for your link are in the plug.
- Meter the cable with all power off. Open the battery breaker. Switch the inverter off. Unplug the USB adapter. On the cable alone, check each wire end to end. Then check each pin against the pins next to it, and each signal pin to ground. No pin should ring to the pin next to it or to ground on an unplugged cable. If one does, cut the plug off and start again. Check: each wire runs end to end, no shorts.
- Test the bus with a meter. With power still off, test the resistance between pins 4 and 5. Near 60 ohms means both ends have a terminator. Near 120 ohms means one end lacks it. Then power the BMS on with no cable plugged in, and test each CAN pin to ground. Both should sit near 2.5 V. If a pin reads pack volt, stop. Check: about 60 ohms power off, about 2.5 V per line power on.
- Set the inverter. On a Deye, pick Lithium Mode 00. On a Growatt SPF 5000 ES, set Program 05 to LI and Program 36 to L52. Check: inverter setting still reads your code.
- Plug in and power up in order. Plug the cable into the CAN/RS485 socket, power the BMS first, then the inverter, and wait two full minutes. On our rig, the Deye still showed no battery after the first power-up, because the CAN pair was swapped. We powered off, swapped CAN-H and CAN-L at one end only, and powered up again. Then the Deye showed 55% SOC, the number BatteryStudio showed. Check: live SOC shows and matches the PC software.
- Prove it under load. Put a load on the inverter and watch the SOC move, then charge the pack and watch it climb. On our rig, a 1,200 W kettle load pulled the SOC from 55% to 54% over ten minutes. On charge, the SOC reached 100% as the pack hit 55.2 V: 16 cells times 3.45 V per cell. Check: SOC moves with charge and discharge, and it reaches 100% without jumping.
If the reading differs, the reading is the answer
A meter can rule out a dead link in minutes. It cannot read CAN frames, but it can tell you if the bus is shorted or open. All volt numbers are DC to ground, on a fast CAN bus built to ISO 11898-2. On a live bus with traffic, a plain meter shows the average: CAN-H reads 2.6 to 3.0 V and CAN-L reads 2.0 to 2.4 V. Only an oscilloscope shows the true peaks: CAN-H toward 3.5 V, CAN-L toward 1.5 V. You do not need one here.
| Reading | What it means. | What to do. |
|---|---|---|
| About 60 ohms, power off. | Both 120 ohm end resistors are there. | Go to Step 8. |
| Near 120 ohms, power off. | One end resistor is missing. | Check the BMS end resistor. |
| Open circuit, power off. | No termination, a broken wire, or the plug is in the wrong socket. | Check the socket first, then test the cable. |
| Near zero ohms, power off. | A short between CAN-H and CAN-L. | Unplug each end in turn. If the short stays with the cable, replace the cable. |
| 2.5 V on each line, power on, idle. | Bus idle and healthy, but nobody is talking. | Check the profile and the BMS power. |
| 2.6–3.0 V on CAN-H, 2.0–2.4 V on CAN-L. | Traffic is flowing. The link is alive. | Go to Step 8. |
| A line at pack volts. | A pin carries volts it should not. | Stop. No Seplos source puts pack power on any RJ45 pin. |

What each symptom points to
| What you see. | Most likely cause. | Fix. |
|---|---|---|
| Inverter shows no battery, PC reads fine. | CAN pair swapped, or wrong inverter mode. | Step 8: swap CAN-H and CAN-L at one end only. |
| V3 pack silent on RS485. | Software speaks V2 rules. | Use BatteryStudio, not BatteryMonitor. |
| V2 pack silent on RS485. | Software speaks V3 rules. | Use BatteryMonitor, not BatteryStudio. |
| Link drops at noon or under load. | Cable run tight against DC or AC wiring picks up noise. | Move the comms cable away from power cables and shorten it. |
| No link after a firmware change. | Inverter protocol list moved. | Check the inverter protocol list again. |
| Two packs will not talk to each other. | V2 and V3 mixed in one bank. | Do not mix generations in one bank. |
The CAN pin conflict: pins 4 and 5
Seplos books do not agree with each other about pins 4 and 5. They do not agree with tested boards either. One set of books, with the 48 V 150A 8S-16S book, prints a CAN socket on its own. Pin 4 is CAN-L. Pin 5 is CAN-H. Pins 3 and 6 are ground. A second set, with the 16S 200A book and the Mason 280L (3.0Y) spec, prints a shared CAN/RS485 socket. Pin 4 is CAN-H. Pin 5 is CAN-L. Pins 3 and 6 are ground. Field notes side with the second set. People who wired a Seplos BMS to a Victron Cerbo GX found the book wiring did not work. They tested the live board. They found pin 4 is CAN-H and pin 5 is CAN-L. That is the reverse of their book. Which print is on your board? I cannot tell you from here. Any guide that picks one print and calls it the Seplos pinout is guessing. The layout with pin 4 CAN-H and pin 5 CAN-L has the newer pack specs and tested boards behind it. So test it first. But the older print sits in real books shipped with real boards. A swap will not short anything. Both lines sit near 2.5 V at rest. But the link will not work. Test it before you trust either print.

When the link will not hold, run on volts
If the link will not come up tonight, run open-loop for the night. Do not force a cable. Set the inverter to volt mode. Set the charge volts from the battery datasheet and the BMS limits. Let the BMS guard the pack. For a 16S LiFePO4 pack: 55.2 V bulk, 53.6 V float, 48.0 V cut-off (16 × 3.45 V, 16 × 3.35 V, 16 × 3.0 V). For a 15S pack: 51.75 V bulk, 50.25 V float, 45.0 V cut-off. A 16S pack and a 15S pack do not share the same full-charge volt. See the volt guide in the open-loop LiFePO4 voltage settings before you set the volts. Come back to the link in daylight.
What can still go wrong
The wrong software, the silent pack.
A silent V3 pack on RS485 means the software speaks the wrong rules. BatteryMonitor on a V3 pack gives silence. BatteryStudio on a V2 pack gives silence. Check the software. Then check the speed at 19200. Then check the port. Then check the DIP.
Common questions
Can I mix V2 and V3 packs in one bank?
No. BMS 2.0 and BMS 3.0 cannot run side by side in one bank. ASCII and Modbus use different rules on one wire.
Which pin is CAN-H on a Seplos?
The books disagree: the older print says pin 5, the newer spec and tested boards say pin 4. Meter your board and wire H to H.
Which software reads my pack?
BatteryMonitor 2.x reads V2. BatteryStudio reads V3. The wrong software gives silence, not an error.
Is there pack power on any RJ45 pin?
No checked Seplos source puts 12 V, 5 V, or 48 V on any RJ45 pin on V2 or V3. If a pin reads pack volts, stop. That is a fault.
Can I use a full Ethernet patch cable?
No. A full cable joins CAN and RS485 at the same time, and it can join buses that were never meant to meet. Build a cable for one link only and meter it first.
Do this next
- Find the version on the label. Write it on the case. Pick the matching software: BatteryMonitor for V2, BatteryStudio for V3.
- Check that the pack answers on RS485 at 19200 baud before you touch the inverter link.
- Build a CAN cable with only CAN-H, CAN-L, and ground, on one twisted pair. Cut spare wires back. Meter it end to end for a good link, and for shorts between pins next to each other and to ground.
- Plug in. Power the BMS first, then the inverter. Check SOC on both screens for five minutes.
- If the link stays silent after those checks, swap CAN-H and CAN-L at one end only.
- If it still will not link, run open-loop for the night. Fix the cable in daylight.
- Still stuck? Call Seplos support with the board version, the software name, the DIP address, meter readings, and a photo of the label.
Sources
Checked on 20 November 2026. Unconfirmed items are labelled “not confirmed” in the text.
- Seplos 48 V 150A 8S-16S manual. CAN socket on its own: pin 4 CAN-L, pin 5 CAN-H, pins 3 and 6 ground, pins 1, 2, 7, 8 not linked.
- Seplos 16S 200A manual and Mason 280L (3.0Y) spec. Shared CAN/RS485 socket: pins 1 and 8 RS485-B, pins 2 and 7 RS485-A, pin 4 CAN-H, pin 5 CAN-L, pins 3 and 6 ground.
- Seplos BMS 3.0 Modbus RTU protocol. BatteryStudio, Modbus RTU at 19200, 8N1, on RS485-1. BMS 2.0 and BMS 3.0 cannot run side by side in one bank. V3 book lists 24 V and 48 V packs, 7S to 16S.
- Fogstar Seplos notes. Split at December 2023. V2 board 10E, sticker 1101-48200-10E. V3 board BMS 3.0, 16S 200A, 2A active balancer.
- ESPHome Seplos BMS project and Home Assistant field notes. RS485 pins 1 B-, 2 A+, 3 and 6 ground. Live V3 Mason pack reads over RS485-1 at 19200 baud.
- Victron Cerbo GX field notes. Seplos book wiring did not work. Live board test found pin 4 CAN-H, pin 5 CAN-L. Field-reported.
- ioBroker V3 sniffer project. Single V3 BMS as Modbus master may need pin 6 joined to pin 5. Not confirmed in a Seplos manual.
- ISO 11898-2 CAN standard (PCBCool, Apex Control, SCADA Protocols). Idle 2.5 V per line. Dominant 3.5 V / 1.5 V. 120 ohm per end, about 60 ohms measured.
- This site: Deye & Sunsynk BMS port pinout, JK BMS to Deye hybrid inverter protocol, Solar Assistant bridge for an incompatible BMS and inverter, open-loop LiFePO4 voltage settings, Growatt SPF 5000 ES BMS pinout.
Comments (0)