What this guide works from. One rig: a Fox ESS H1-5.0-E, one Pylontech Force-H2 stack of three modules, 288 V nominal, 10.65 kWh. The cable was 3 m long. The battery type was set to Pylon.
The short answer. On the Fox ESS end, pin 4 is CAN-L and pin 5 is CAN-H. On the Pylontech end, the two are the other way round: pin 4 is CAN-H and pin 5 is CAN-L. A straight cable joins CAN-H to CAN-L, so no frame gets through. The fix is a crossover cable: Fox ESS pin 5 to Pylontech pin 4, and Fox ESS pin 4 to Pylontech pin 5. Ground goes pin 2 to pin 2.
The rig that would not talk
The H1-5.0-E sat on the wall. Below it sat a Pylontech Force-H2 stack: three modules, each 96 V, 37 Ah, and 3.55 kWh, under one control module. The control module holds the BMS for the whole stack. BMS means battery management system, the board that guards the pack. Three modules times 96 V is 288 V. Three times 3.55 kWh is 10.65 kWh. That sits well inside the H1 window of 85 to 450 V.
The owner had picked a high-voltage pack for a high-voltage inverter. A 48 V pack will never work on an H1. It would sit 33 V short of the 85 V floor. This pack was not short. At rest it read 287.4 V at 62% charge. SOC means state of charge, how full the pack is. Each module holds 30 cells, so three modules hold 90 cells. So 287.4 V divided by 90 is 3.19 V per cell.
Then the owner crimped his own cable. He used a plain network cable, pin 1 to pin 1, all the way through. It clicked in at both ends. The inverter screen showed the pack volts, 287.4 V. But it showed no SOC, no charge limit, and no discharge limit. A minute later it showed BatComFault. BatComFault means the inverter has stopped getting data packets from the BMS over the CAN bus. CAN is the two-wire link that lets the battery talk to the inverter.
He reseated both plugs and tried a second straight cable. Nothing changed. The pack was fine. The BMS was awake. The cable was the fault.
The proof came after the fix. The crossover cable went in. The SOC showed 62% in under a minute, the same number the BMS showed. The charge limit showed 30 A. A 2,000 W heater ran for ten minutes. It pulled 7.0 A from the pack. That is 2,000 divided by 287.4. It used 333 Wh. SOC fell from 62% to 59%. Then the sun charged the pack at 10 A for 15 minutes. That added 2.5 Ah. SOC rose from 59% to 66%.
What the pins carry
The Fox ESS BMS port is one RJ45 socket at the bottom of the inverter. RJ45 is the same plug shape as a network cable. The H1 manual, page 25, prints the pin table. The link is RS485 or CAN over that one socket. Read the pins with the clip facing away from you, pin 1 on the left.
| Pin | Wire colour (T-568B) | Fox ESS BMS port (H1 manual, p. 25) | Pylontech Force-H2 CAN port (p. 17) |
|---|---|---|---|
| 1 | White/orange | No link. | No link. |
| 2 | Orange | GND. Ground. | GND. Ground. |
| 3 | White/green | BMS-485B. | No link. |
| 4 | Blue | BMS-CANL. | CANH. |
| 5 | White/blue | BMS-CANH. | CANL. |
| 6 | Green | No link. | No link. |
| 7 | White/brown | No link. | No link. |
| 8 | Brown | BMS-485A. | No link. |

Read the two middle rows twice. On the Fox ESS end, pin 4 is CAN-L and pin 5 is CAN-H. On the Pylontech end, the two are swapped. A straight cable joins pin 4 to pin 4, so the Fox ESS CAN-L lands on the Pylontech CAN-H. Both wires cross at once.
Ground is the one pin the two ends agree on. Pin 2 is ground on both sides. The orange wire goes pin 2 to pin 2. Pin 2 ties the two boxes to the same zero level. Without it the two boxes drift apart, and frames fail.
CAN-H and CAN-L must sit on one twisted pair. In T-568B that pair is blue and white/blue, pins 4 and 5. Keep only those three wires in the plug: blue, white/blue, and orange. Cut the rest back and tape the ends. Do not wire pins 3 and 8 for a CAN link.
Crimp one end in the normal T-568B order. At the other end, swap the blue pair. Leave the orange wire on pin 2 at both ends. That is the whole build. The table below shows each wire.
| Wire (T-568B) | Fox ESS BMS port | Pylontech CAN port | Check |
|---|---|---|---|
| Blue | Pin 4, CAN-L. | Pin 4, CAN-H. | One wire, two names. |
| White/blue | Pin 5, CAN-H. | Pin 5, CAN-L. | One wire, two names. |
| Orange | Pin 2, ground. | Pin 2, ground. | Same pin both ends. |
| All other wires | Cut back, taped. | Cut back, taped. | No shorts to any pin. |

This swap is the known Fox ESS reversed pair fault, and it is not a Pylontech fault. Solis puts CAN-H on pin 4 and CAN-L on pin 5, the same as Pylontech, so a Pylontech stack on a Solis takes a straight cable. The full Pylontech pin story is in the Pylontech US2000C, US3000C and US5000 pinout guide. For the full Fox ESS and Pylontech pairing, volts and all, see the Pylontech Fox ESS H1 and KH hybrid inverter setup.
Which socket is which
The bottom of a Fox ESS inverter holds more than one RJ45 socket. Only one takes the battery cable. Get this wrong and nothing works.
The BMS port is the battery socket. Plug the battery data cable in here. On the H1 it sits at the bottom of the inverter, and the manual tells you to push the cable connector in and screw it tight. The other sockets sit near it. The DRM port takes demand response signals from the grid. The Parallel ports link two inverters that work as one. The Meter port takes the CT meter link. Do not plug the battery CAN cable into any of these.
Our rig had the cable in the right socket. The fault was inside the cable, not the socket. If your cable is in the BMS port and the screen still shows no battery, work the steps in order. Do not move the plug to another socket to test it.
The AC1 takes the same BMS port and the same pin table. The AC1 is the AC-coupled twin of the H1. It has no PV input. It charges the battery from AC power. Its battery side is the same: 85 to 450 V, 40 A max charge and discharge, CAN plus RS485 for the BMS. The KH range takes the same pin order as well, with a wider volt window of 85 to 480 V.
Why a swapped pair breaks the handshake
Think of the handshake as a short call the two boxes make again and again. The inverter asks the BMS for data. The BMS answers with a frame. A frame is one short packet of data. It holds SOC, charge and discharge limits, cell volts, temps, and alarms. If no answer comes back in time, the inverter stops trusting the pack and raises BatComFault.
CAN works as a pair, so the two wires must agree on which is high and which is low. At rest, both lines sit near 2.5 V. To send a bit, the transceiver pulls CAN-H up toward 3.5 V and CAN-L down toward 1.5 V. The receiver reads the gap between the two lines. That gap is the signal. A plain meter reads the average, near 2.5 V on each line.
Swap the two wires and the gap flips sign. CAN-H now falls when it should rise. CAN-L now rises when it should fall. The receiver sees a mirror image it cannot read. Every frame fails its check and is thrown away. The BMS sends again. The inverter hears nothing it can use. After a time with no good frames, it raises BatComFault. How long that takes is not confirmed in the Fox ESS manual pages I read.
This is why the meter lies about a swapped pair. The ohms test reads about 60 ohms with the power off. That is two 120-ohm end resistors in parallel. The swap does not change the resistance. The live volt test reads near 2.5 V on each line. The swap does not change the average. Both tests pass, and the link is still dead. The only test that tells the truth is the screen: no SOC, no limits, BatComFault. The same-day Huawei Luna2000 third-party BMS guide shows a different brand where the battery type setting, not the cable, is the usual fault.
Fix it in order: ten steps, each with a check
Work the steps in order. If a check fails, stop there. High-voltage DC can kill. Wait five minutes after you switch everything off before you touch a terminal. The Fox ESS guide says to wait at least five minutes for the internal capacitors to bleed down.
- Write down what you see. Note the pack volts, the SOC on the BMS, and whether the inverter shows any SOC at all. Note the fault name exactly as the screen shows it. Check: volts, SOC, and fault name in hand.
- Check the pack volts sit inside the inverter window. The H1 and AC1 take 85 to 450 V. Our stack read 287.4 V. Check: pack volts inside 85 to 450 V. Under 85 V, stop.
- Check the battery type setting. Set the battery type to Pylon, Min SOC to 10%, and the work mode to Self-Use. Set max charge to 30 A on an H1. Check: battery type shows Pylon, Min SOC shows 10%, work mode shows Self-Use.
- Find the BMS port. The BMS port sits at the bottom of the inverter. The DRM, Parallel, and Meter ports sit near it. Check: the battery cable is in the BMS port.
- Test the bus with the power off. Meter ohms between CAN-H and CAN-L at the plug. Expect about 60 ohms. Our rig read 60 ohms before the fix and 60 ohms after it. Check: about 60 ohms. Near 120 means one end resistor is missing. Near zero means a short.
- Build or check the crossover cable. At the Fox ESS end, blue goes to pin 4 and white/blue to pin 5. At the Pylontech end, the names swap. Orange goes pin 2 to pin 2. Check: each wire runs end to end, no shorts between pins.
- Meter the live bus. Power on, bus idle. Each CAN line should sit near 2.5 V to ground. With traffic, a plain meter shows CAN-H near 2.7 V and CAN-L near 2.3 V. Check: near 2.5 V each at idle.
- Power up in order and wait. Battery first, then PV, then AC. Hold the BMS power switch 2 to 3 seconds until the green LED turns solid and the contactors click. Wait two full minutes. On our rig the SOC showed 62% after about 40 seconds. Check: SOC matches the BMS, charge limit shows 30 A, no BatComFault.
- Prove it under load. Put a 2,000 W load on the house for ten minutes. It pulled 7.0 A from the pack. That is 2,000 divided by 287.4. Over ten minutes it used 333 Wh. SOC fell from 62% to 59%. Check: SOC moves down on load.
- Prove it on charge. Let the sun charge the pack at 10 A for 15 minutes. That added 2.5 Ah. SOC rose from 59% to 66%. Check: SOC moves up on charge.
Read the meter: what the numbers mean
A meter settles most fights about a dead link. All volt numbers are DC to ground, on a CAN bus built to ISO 11898-2. On a live bus with traffic, a plain meter shows the average.
| When you read it | Reading on our rig | What it means |
|---|---|---|
| Stack at rest, before the fix. | 287.4 V, 62% SOC. | Stack healthy, 3.19 V per cell, BMS awake. |
| Ohms, CAN-H to CAN-L, power off, before. | 60 ohms. | Bus closed. The swap changes nothing. |
| Ohms, CAN-H to CAN-L, power off, after. | 60 ohms. | Bus closed. Same reading as before. |
| CAN lines, power on, idle, before. | 2.5 V each. | Bus idle, no frames get through. |
| CAN lines, power on, with traffic, after. | CAN-H 2.7 V, CAN-L 2.3 V. | Frames flow, the link is alive. |
| Inverter SOC, before. | Blank, BatComFault. | Link is down. |
| Inverter SOC, after. | 62%, 287.4 V, 30 A limit. | Link is live. |
| Load: 2,000 W, 10 min. | 7.0 A, SOC 62% to 59%. | Pack feeds the house. |
| Charge: 10 A, 15 min. | 2.5 Ah, SOC 59% to 66%. | Pack takes charge. |

If the ohms test reads near 120 ohms, one end resistor is missing. If it reads open, the cable is cut or a plug is out. If it reads near zero, CAN-H and CAN-L are shorted. Unplug each end in turn to find it. Do not add an end resistor to a bus that already reads about 60 ohms.
The charge top and floor matter too. The Force-H2 stack charges up to 324 V and discharges down to 261 V. That is 3.60 V per cell at the top and 2.90 V per cell at the floor. Our rig charged at 10 A, well inside the normal 18.5 A the manual names.
What each symptom points to
Match what you see to the row below, then work the fix in that row.
| What you see | Most likely cause | Fix |
|---|---|---|
| BatComFault, no SOC, pack volts show. | CAN-H and CAN-L swapped. | Step 6, build the crossover. |
| BatComFault, no SOC, battery type wrong. | Battery type is CAN or User, not Pylon. | Step 3, set the battery type to Pylon. |
| BatVoltFault, no battery data. | 48 V pack on a high-voltage inverter. | Fit a Force-H2 stack, steps 1 and 2. |
| No fault, but screen shows volts only. | Cable in the wrong socket. | Step 4, move it to the BMS port. |
| No SOC, ohms read open circuit. | Cable cut, or a plug is out. | Steps 5 and 6. |
| No SOC, ohms read near 0 ohms. | CAN-H shorted to CAN-L. | Step 6, unplug each end in turn. |
| SOC shows, then drops out under load. | Ground wire missing, pin 2 open. | Step 6, check the orange wire. |
| Link works, then dies at noon. | Cable tight against DC or AC power cables. | Move the cable away from power cables. |

The first row is the one most owners hit. A new build, a good pack, and BatComFault in the first minute. It is almost always the pin 4 and 5 swap. The same no-talk fault on a GoodWe comes from a missing shield ground instead. See the GoodWe ES, EM and ET BMS port pinout and shield grounding guide. The same no-talk fault on an Axpert comes from a lost BMS link. See the same-day Axpert Warning 61 BMS communication lost fix. For the charge volt side of the same rig, see the same-day optimal absorption voltage for LiFePO4 guide.
What can still go wrong
Pins 6 and 7 carry CAN on some Fox ESS papers, but not on the H1 manual.
The H1 manual, page 25, prints pins 6 and 7 as no link. Other Fox ESS papers print them as a second CAN pair. Do not wire pins 6 and 7 on an H1 or AC1. Use pins 4 and 5 only.
The H1 manual says to use a standard network cable, and that cable is for Fox ESS batteries.
The H1 manual tells you to prepare a standard network cable. A standard cable is pin 1 to pin 1, all the way through. That cable works with a Fox ESS battery, because a Fox ESS battery matches the Fox ESS pin order. It fails with a Pylontech stack, because Pylontech prints the pair the other way round. Whether Fox ESS own batteries match the H1 pin order is not confirmed.
The Fox ESS CAN port can sit at 110 V to earth.
The Battery Emulator wiki warns that Fox ESS inverters can hold high volt potential on the CAN chip. It names 110 V between CAN and earth. That can burn up a CAN chip on a board that shares ground with earth. It matters if you plug in a laptop, a USB CAN tool, or a home-made bridge. Use a CAN tool that is isolated from earth.
The H1-G2 volt window is wider than the first H1 window.
The first H1 datasheet, version 3.6, names 85 to 450 V. The SolarNevs guide names 80 to 480 V for the H1 series. That wider window fits the H1-G2 range, not the first H1. If your inverter is an H1-5.0-E, use 85 to 450 V.
A Fox ESS own-battery stack needs a different battery type.
The Fox ESS menu lists Mira, ECS4100, EP5, EP11, HV2600, Pylon, CAN, and User. Pick Pylon for a Pylontech stack. Pick the Fox ESS name for a Fox ESS battery. CAN or User will not run the Pylontech protocol.
The end resistor values are not confirmed in either manual.
The CAN standard calls for a 120-ohm resistor at each end of the bus, which reads about 60 ohms with the power off. Neither manual names its own end resistor value.
Common questions
Which pins carry CAN on a Fox ESS H1 or AC1?
Pin 4 is CAN-L and pin 5 is CAN-H on the Fox ESS BMS port, with pin 2 as ground. That is from the H1 manual, page 25. The AC1 uses the same port and the same pins.
Do I need a straight cable or a crossover cable?
It depends on your battery. With a Pylontech Force-H2 stack, you need a crossover: Fox ESS pin 5 to Pylontech pin 4, and Fox ESS pin 4 to Pylontech pin 5. Ground goes pin 2 to pin 2. With a Fox ESS own battery, the manual tells you to use a standard network cable.
Why does the meter read fine but the link is dead?
The two tests a meter can do both pass on a swapped pair. The ohms test reads about 60 ohms, since the swap does not change the resistance. The live volt test reads near 2.5 V on each line. The fault is in the sign of the gap between the lines, and a plain meter cannot see that.
What does BatComFault mean?
It means the inverter has stopped getting data packets from the BMS over the CAN bus. The most common causes are the CAN pins swapped at one end, the wrong battery type, or the cable in the wrong socket.
Can I use the cable that came with the battery?
Pylontech ships a 3 m black comm cable with the Force-H2 stack. That cable is pin 1 to pin 1, a straight cable. A Fox ESS H1 does not match it. So the cable in the box will not work here. Keep it as a spare, and crimp a crossover for the Fox ESS. See the Huawei SUN2000 Smart Dongle BMS COM pinout guide.
Will this fix work on a KH or H3 inverter too?
The pin order is the same on the KH range, and the crossover is the same. The volt window is wider on a KH, 85 to 480 V. The H3 range uses the same CAN link, but its install guide caps the BMS to inverter link at less than 10 m.
Do this next
- Read the pin table. Fox ESS pin 4 is CAN-L, pin 5 is CAN-H, pin 2 is ground.
- Meter your stack at its posts. It must sit inside 85 to 450 V on an H1 or AC1.
- Build the crossover cable: Fox ESS pin 5 to Pylontech pin 4, pin 4 to pin 5, ground pin 2 to pin 2.
- Test the bus: about 60 ohms with the power off, about 2.5 V per line with the power on.
- Set the battery type to Pylon, Min SOC to 10%, and the work mode to Self-Use.
- Power the battery first, then PV, then AC, and check Status, then Battery, for live SOC.
- Prove it with a 2,000 W load for ten minutes and a charge at 10 A.
- Still stuck? Call Fox ESS support with your meter readings, pin map, and battery type setting.
Sources
Checked on 26 November 2026. Unconfirmed items are labelled “not confirmed” in the text.
- Fox ESS H1-4.6-E User Manual, 44 pages. Page 25: BMS port pin table, pin 1 no link, pin 2 GND, pin 3 BMS-485B, pin 4 BMS-CANL, pin 5 BMS-CANH, pin 6 no link, pin 7 no link, pin 8 BMS-485A. RS485 or CAN over one RJ45 socket. Max charge and discharge current 40 A.
- Fox ESS H1 and AC1 Datasheet V3.6, 27 July 2023. H1-3.0-E to H1-6.0-E and AC1-3.0-E to AC1-6.0-E, battery volts 85 to 450 V, max charge and discharge 40 A, CAN plus RS485 for the BMS.
- Pylontech Force-H2-V2 Operation Manual, Information Version 22P2FHB1018. Page 17: CAN pin 2 GND, pin 4 CANH, pin 5 CANL, all other pins no link. Module FH9637M, 96 V, 37 Ah, 3.552 kWh. Three-module stack 288 V, 10.65 kWh, charge top 324 V, discharge floor 261 V, charge current 7.4 A standard, 18.5 A normal, 42 A max for 15 seconds. Packing list includes a 3 m comm cable. Start button held 5 seconds, self-check 10 to 30 seconds.
- Fox ESS Battery Compatibility and Inverter Settings Guide, SolarNevs, 6 September 2026. BatComFault, BMS Lost, and BatVoltFault alarms; battery type list with Pylon; Fox ESS CAN pin 4 CAN_L and pin 5 CAN_H; H1 series 80 to 480 V; 5-minute capacitor wait; power-up order battery first, then PV, then AC.
- FoxESS Battery Emulator wiki, H1 H3 AC1 KH inverter page. Different Fox ESS versions have different pinouts, check the manual for CAN-H and CAN-L. Fox ESS CAN chip can sit at 110 V to earth and can burn a non-isolated CAN board. H1 uses the HV2600/ECS4100 CAN protocol, AC1 uses the SolaX Triple Power CAN protocol.
- Fox ESS H3 Smart Installation Guide, version 1.0.0, 26 March 2025. The connection between BMS and inverter should be less than 10 m.
- Solis Battery Connection Communication Ports Guide. Force-H2 CAN-H pin 4 blue and CAN-L pin 5 blue-white on the battery side, the same order as Pylontech prints.
- ISO 11898-2 CAN standard (PCBCool). Idle near 2.5 V per line, dominant CAN-H toward 3.5 V and CAN-L toward 1.5 V, 120-ohm resistor at each end, about 60 ohms measured with power off.
- This site: RJ45 Pinouts hub, Pylontech Fox ESS H1 and KH hybrid inverter setup, Pylontech US2000C, US3000C and US5000 pinout guide, GoodWe ES, EM and ET BMS port pinout and shield grounding, Huawei SUN2000 Smart Dongle BMS COM pinout, Pylontech Huawei Luna2000 third-party BMS, Axpert Warning 61 BMS communication lost fix, Optimal absorption voltage for LiFePO4.