Which Pylontech Port Takes the Inverter Cable? A/CAN or B/RS485?

Farhan Ahamed
Farhan Ahamed Published November 19, 2026 · 15 min read
0 COMMENTS
Which Pylontech Port Takes the Inverter Cable? A/CAN or B/RS485?
IN THIS GUIDE · QUICK JUMP KEY SECTIONS
01 · KEY SECTION Jump ↓

The rig that would not link

It was a new build, and it looked right. The SPF 5000 ES sat…

02 · KEY SECTION Jump ↓

What the pins carry

Each pack has two RJ45 sockets on the front, A/CAN and B/RS485, and the…

03 · KEY SECTION Jump ↓

Which setting fits your battery

The three models sit side by side in the table below. All three are…

04 · KEY SECTION Jump ↓

Why the pin order matters

A dead Pylontech link is a handshake fault. A handshake is the short exchange…

05 · KEY SECTION Jump ↓

Fix it in order: nine steps, each with a check

Work the steps in order. If a check fails, stop there.

06 · KEY SECTION Jump ↓

If the reading differs, the reading is the answer

A meter can rule out a dead link in minutes. It cannot read CAN…

07 · KEY SECTION Jump ↓

What each symptom points to

Step-by-step field verification & diagnostic reference inside this section.

08 · KEY SECTION Jump ↓

The console port and the wake-up pins

The US3000C has one more RJ45 port, the console port, for a PC, not…

09 · KEY SECTION Jump ↓

When the link will not hold, run on volts

If the link will not come up tonight, run open-loop for the night. Do…

10 · KEY SECTION Jump ↓

What can still go wrong

Step-by-step field verification & diagnostic reference inside this section.

11 · KEY SECTION Jump ↓

Common questions

Step-by-step field verification & diagnostic reference inside this section.

12 · KEY SECTION Jump ↓

Do this next

Step-by-step field verification & diagnostic reference inside this section.

What this guide works from. One rig: two Pylontech US3000C packs, a Growatt SPF 5000 ES, the master pack on top, 15 cells per pack, the bank resting at 51.9 V, the inverter screen showing no SOC at first.

The short answer. All three Pylontech models use the same RJ45 pin map. For a CAN link, use pins 4 and 5 on the A/CAN port. Pin 4 is CAN-H, pin 5 is CAN-L, and pin 6 is CAN-GND. For RS485, use pins 7 and 8 on the B/RS485 port. On our rig, the fault was the DIP switch: Dip2 sat at 1, so the CAN end cap was out, and the bus read near 120 ohms. We set Dip2 to 0, restarted the pack, and the Growatt showed 48% SOC within two minutes.

The rig that would not link

It was a new build, and it looked right. The SPF 5000 ES sat on the wall, and two US3000C packs sat below it, chained by a link cable. The bank read 51.9 V: 3.46 V per cell, times 15 cells. Each pack is 15S, 15 cells in a row, so do not set the inverter as if it were a 16S pack. A 16S charge goal would overcharge the pack. Then the inverter was switched on. The Growatt home screen showed pack volts, but no SOC and no battery data. State of charge, or SOC, is how full the battery is. The inverter still saw 51.9 V on the DC cables, but it had no data: no SOC, no charge limit, no cell temps. Without data, the inverter will not trust the battery. On Program 05 LI it cuts output when the link fails.

What the pins carry

Each pack has two RJ45 sockets on the front, A/CAN and B/RS485, and the pin map is the same on both. Pin 4 is CAN-H, pin 5 is CAN-L, pin 6 is CAN-GND, pin 7 is 485A, and pin 8 is 485B. Pins 1 to 3 are NULL, which means they must stay unconnected. Count pins with the clip turned away from you. Pin 1 is on the left. CAN runs at 500 kbps with 120 ohm termination. RS485 runs at 9600 or 115200 bps, set by the DIP switch. A CAN inverter needs frames on pins 4 and 5, and an RS485 inverter needs replies on pins 7 and 8. Pick one bus, wire only that bus, and set the inverter to match. The full Growatt side of the link is the Growatt SPF 5000 ES BMS pinout.

PinWireWhat it does.
1NULLMust stay unconnected.
2NULLMust stay unconnected.
3NULLMust stay unconnected.
4CAN-HCAN data, high line.
5CAN-LCAN data, low line.
6CAN-GNDCAN ground wire.
7485ARS485 data, A side.
8485BRS485 data, B side.

For CAN, use the A/CAN port on the master, the pack that leads the group. Carry pins 4, 5 and 6 only, with CAN-H and CAN-L on the same twisted pair: the blue pair in T568B, pin 4 solid blue and pin 5 white and blue. Cut the other wires back at the jacket. For RS485, use the B/RS485 port, pins 7 and 8 only. Check the A and B order at both ends first. A flipped RS485 pair looks just like a dead cable. Pin 6 is the ground wire for CAN. A 2-wire CAN cable with pins 4 and 5 only works in most cases, and works fine on short runs. But on long runs, or runs with lots of hum from near wires, the link can fail, and adding the pin 6 ground wire has fixed it. If your inverter book shows a ground pin, join pin 6 to it.

Which setting fits your battery

The three models sit side by side in the table below. All three are 15S LiFePO4 packs at 48 V, and you can put up to 16 packs in one group. Use the 15S charge numbers from the Pylontech book for your exact model. The inverter cable goes to the master, not to a slave or to the middle of the chain. Plug the inverter into a slave and it may see nothing at all. The master is the pack whose Link Port 0 is empty. In mixed sets, the newest model is master. The order is US5000 first, then UP5000, US3000C and US2000C, then US3000 and US2000.

ModelCapacityUsable (95% DoD)Recommended currentSize (mm)Weight
US2000C2.4 kWh (50 Ah)2.28 kWh25 A442 x 410 x 8922.5 kg
US3000C3.552 kWh (74 Ah)3.37 kWh37 A442 x 420 x 13232 kg
US50004.8 kWh (100 Ah)4.56 kWh100 A442 x 420 x 16139.7 kg

The ADD switch block sits on the front of the pack. Two of its switches decide if the link works at all. Set both first, then turn the pack on. Dip1 sets the RS485 baud rate: 1 means 9600 bps, 0 means 115200 bps. For a Growatt SPF on RS485 at 9600 bps, set Dip1 to 1. Dip2 sets CAN termination. Dip2 at 1 means NONE, Dip2 at 0 means the end cap is in. In single-group mode, keep Dip2 at 0. Restart the pack after any DIP change. Leave Dip3 and Dip4, which are reserved, where the book says. Note that they sit in reverse on the board. The full Growatt menu pairing is the Pylontech US2000/US3000 Growatt Menu 05 & 36 guide.

Why the pin order matters

A dead Pylontech link is a handshake fault. A handshake is the short exchange where two units agree they can talk. The inverter sends a frame on the CAN bus: one short packet of data. The BMS must answer with its own frame: SOC, charge limit, cell volts, temps, alarms. If no answer comes back in time, the inverter shows no battery and stops trusting the pack. The talk failed. That talk can fail in only four ways: the wire is wrong, the port is wrong, the DIP is wrong, or the bus is broken. A reboot fixes none of these. It changes nothing about the wire, the DIP, or a cable plugged into a slave pack. One rare case: the BMS was asleep and woke up during the power cycle. That is luck, not a fix.

CAN works as a pair. CAN-H and CAN-L are two wires that move in step, one up and one down. The twist in the pair cancels noise from near wires. That is why the two CAN wires must sit on the same twisted pair in the cable, most often the blue pair in T-568B, pins 4 and 5. If CAN-H and CAN-L are swapped, each line still sits near 2.5 V at rest. The meter looks fine, but no frame gets through. The bus is dead, and the volts lie to you.

A straight Ethernet cable is the most common wire fault here. A patch cable is wired pin to pin for a network switch, not for a BMS port. On a Pylontech pack, a patch cable joins all eight pins straight across: pins 1 to 3, which must stay unconnected, and pins 7 and 8, the RS485 pair, at the same time as the CAN pair on pins 4 and 5. The book warns that other pins may upset comms, and this is the exact case it means.

Fix it in order: nine steps, each with a check

Work the steps in order. If a check fails, stop there.

  1. Find the master. Look for the pack with an empty Link Port 0. In a mixed set, the newest model is master: US5000 first, then UP5000, US3000C and US2000C, then US3000 and US2000. Photograph the ADD switch block on the master. Check: master found, Link Port 0 empty.
  2. Set the ADD switches. For CAN in a single group, set Dip2 to 0 so the end cap is in. For RS485 on a Growatt SPF at 9600 bps, set Dip1 to 1. Leave Dip3 and Dip4 where the book says. On our rig, this was the fault: Dip2 sat at 1, so the end cap was out. We set it to 0. Check: Dip2 at 0 for CAN, Dip1 set for your RS485 speed.
  3. Restart the pack. Turn the pack off, wait ten seconds, then turn it back on. A DIP change does nothing until the pack restarts. Check: pack restarts and the screen comes back.
  4. Build the cable. For CAN, use pins 4, 5 and 6 only: blue to pin 4, white/blue to pin 5, green to pin 6. Cut the other five wires back at the jacket and tape the cut ends. For RS485, use pins 7 and 8 only. Use shielded Cat5e or Cat6, keep the run short, and route it far from DC and AC wires. Check: only the pins for your bus are in the plug.
  5. Meter the cable before you plug it in. Check that each wire runs all the way through, pin to pin. Then check that no pin is shorted to the one next to it. One stray strand of wire between pins 4 and 5 will hold the CAN bus down. Check: each wire runs end to end, no shorts between pins.
  6. Set the inverter. On a Growatt SPF 5000 ES, set Program 05 to LI and Program 36 to L52 for CAN, or L02 for RS485. On a Deye, pick Lithium Mode 00 for Pylontech CAN. Check: inverter setting still reads your code.
  7. Test the bus with a meter. With all power off, test ohms between CAN-H and CAN-L. A good bus reads about 60 ohms (two 120 ohm end resistors in parallel). On our rig, the power-off test read near 120 ohms before the Dip2 fix, and 61 ohms after it. With power on and the bus idle, test each line to ground: each should sit near 2.5 V DC. Check: about 60 ohms power off, about 2.5 V per line power on.
  8. Plug into the master and power up in order. Plug the inverter cable into the master A/CAN port for CAN, or the B/RS485 port for RS485. Turn the pack on first, then the inverter, and wait two full minutes. On our rig, the Growatt showed 48% SOC after about 40 seconds. Check: live SOC shows and moves with charge.
  9. Prove it under load. Put a load on the inverter and watch the SOC move, then charge the pack and watch it climb. On our rig, a 1,200 W kettle load pulled the SOC from 48% to 47% over ten minutes. On charge, the SOC reached 100% as the bank hit 51.75 V: 15 cells times 3.45 V per cell. Label the DIP settings and stick the label on the inside of the cabinet door. Check: SOC moves with charge and discharge, and it reaches 100% without jumping.

If the reading differs, the reading is the answer

A meter can rule out a dead link in minutes. It cannot read CAN frames, but it can tell you if the bus is shorted or open. All volt numbers are DC to ground, on a fast CAN bus built to ISO 11898-2. On a live bus with traffic, a plain meter shows the average: CAN-H reads 2.6 to 3.0 V and CAN-L reads 2.0 to 2.4 V. Only an oscilloscope shows the true peaks: CAN-H toward 3.5 V, CAN-L toward 1.5 V. You do not need one here.

ReadingWhat it means.What to do.
About 60 ohms, power off.Both 120 ohm end resistors are there.Go to Step 8.
Near 120 ohms, power off.One end resistor is missing.Check Dip2 on the master. Set it to 0.
Open circuit, power off.No termination, a broken wire, or the plug is in a slave pack.Check the master first, then test the cable.
Near zero ohms, power off.A short between CAN-H and CAN-L.Unplug each end in turn. If the short stays with the cable, replace the cable.
2.5 V on each line, power on, idle.Bus idle and healthy, but nobody is talking.Check the inverter profile and the BMS power.
2.6–3.0 V on CAN-H, 2.0–2.4 V on CAN-L.Traffic is flowing. The link is alive.Go to Step 8.
0 V or pack volts on one line.That line is shorted, or the signal chip is dead.Stop. Unplug the BMS end. If the line clears, the fault is in the BMS.

For RS485, the same idea holds with different pins. Flipped A and B is a common fault on third-party cables. If RS485 will not link, swap A and B at one end only, then test again. A cheap cable tester will not catch a wrong pin map. It only checks that each wire runs end to end. A straight cable passes the test and is still wrong for a BMS link.

What each symptom points to

What you see.Most likely cause.Fix.
Inverter shows no battery, volts fine.Cable in a slave pack, or wrong DIP.Steps 1 and 2: find the master, set Dip2 to 0.
120 ohm read on the bus.Dip2 at 1, end cap out.Set Dip2 to 0, restart the pack.
Link drops at noon or under load.Cable run tight against DC or AC wiring picks up noise.Move the comms cable away from power cables and shorten it.
RS485 will not link at all.Dip1 set for the wrong speed, or A and B flipped.Set Dip1 for your speed, then swap A and B at one end.
Link worked, then died after a firmware update.Inverter protocol list moved.Check the inverter protocol list again.
No link on a Victron.Wrong Victron CAN cable type.Type A for C models, Type B for old models.

The console port and the wake-up pins

The US3000C has one more RJ45 port, the console port, for a PC, not for the inverter. You use it with BatteryView, Pylontech’s PC tool for pack data and new firmware. The console port pinout is short. Pin 3 is TX (send), pin 6 is RX (receive), and pin 8 is GND (ground). The baud rate is 115200. Use this port only for a PC and BatteryView, not for the inverter. The wake-up signal is on this same console port. Pin 4 is the +5 to 12 V wake-up pin, and pin 5 is its ground. The signal must last at least 0.5 sec and draw 5 to 15 mA. Do not wire the wake-up pins to the inverter. They are for the PC tool only. BatteryView is how you load new firmware on a US3000C. The US3000C uses US_C firmware, so check that the file name starts with US_C. Do not cut power while it loads.

When the link will not hold, run on volts

If the link will not come up tonight, run open-loop for the night. Do not force a cable. Set the inverter to volt mode. Set the charge volts from the battery datasheet and the BMS limits. Let the BMS guard the pack. For a 15S Pylontech pack: 51.75 V bulk, 50.25 V float, 45.0 V cut-off (15 × 3.45 V, 15 × 3.35 V, 15 × 3.0 V). For a 16S pack: 55.2 V bulk, 53.6 V float, 48.0 V cut-off. A 15S pack and a 16S pack do not share the same full-charge volt. Get the pack size right first. See the volt guide in the open-loop LiFePO4 voltage settings before you set the volts. Come back to the comms link in daylight, with a meter and a fresh plug. The Growatt Error 20 walk-through is the Growatt Error 20 BMS communication fix.

What can still go wrong

Victron CAN cables: Type A or Type B.

If you use a Victron inverter, buy the right Victron CAN cable. There are two types, and they look the same but are not. Type A is part ASS030710018, for the US2000C, US3000C, UP5000 and Force-L. Type B is part ASS030720018, for the US2000, US3000 and UP2500. The C at the end means a new model: the old models take Type B, the C models take Type A. If you use the wrong type, you get no link at all. Match the part number to the model name.

The used-pack check.

The US2000C and US3000C are no longer on Pylontech’s July 2026 low-voltage list. The books still back them, but a pack off the new list is one your inverter maker may not test with now. Check your inverter’s new list before you buy a used US2000C or US3000C. The US5000 is the safer buy if you start from scratch.

The cable that worked yesterday.

A comms cable run tight against DC lugs or AC wires can pick up noise when current peaks. That is why a fault that clears in the morning can come back at noon. If the link drops under load, move the cable and shorten it.

The DIP that did nothing.

A DIP change does nothing until the pack restarts. If the bus still reads 120 ohms after you set Dip2 to 0, restart the pack and test again.

Common questions

Do all three models use the same pin map?

Yes. The US2000C, US3000C and US5000 share one pin map on both ports. CAN-H is pin 4, CAN-L is pin 5, CAN-GND is pin 6, RS485 is pins 7 and 8, and pins 1 to 3 are NULL.

Can I use a straight Ethernet cable?

No. A straight cable joins pins 1 to 3, which must stay unconnected, and the RS485 pair at the same time as the CAN pair. Build a cable with only the pins your link needs.

Which pack is the master?

The pack with an empty Link Port 0. In a mixed set, the newest model is master: US5000 first, then UP5000, US3000C and US2000C, then US3000 and US2000.

What does Dip2 do?

Dip2 sets CAN termination. Dip2 at 1 means NONE, Dip2 at 0 means the end cap is in. Keep Dip2 at 0 in single-group mode, and restart the pack after any change.

Can I wake the pack from the inverter?

No. The wake-up pins sit on the console port, pin 4 at +5 to 12 V and pin 5 ground, for the PC tool only. Do not wire them to the inverter.

Do this next

  1. Find the master, the pack with the empty Link Port 0. Photograph its ADD switch block.
  2. Set Dip2 to 0 for CAN, or Dip1 for your RS485 speed, then restart the pack.
  3. Build a cable with only the pins for your bus: CAN pins 4, 5 and 6, or RS485 pins 7 and 8. Meter it first.
  4. Set the inverter to the Pylontech profile for the bus you wired: L52 on a Growatt SPF, Lithium Mode 00 on a Deye.
  5. Test the bus: about 60 ohms with power off, about 2.5 V per line with power on and idle.
  6. Plug into the master, turn the pack on first, then the inverter, and watch for a live SOC.
  7. Still stuck? Call Pylontech support with model names, DIP settings, meter readings, and a photo of the ADD block.

Sources

Checked on 20 November 2026. Unconfirmed items are labelled “not confirmed” in the text.

QUESTIONS ANSWERED

Operator Questions Answered (Playbook FAQ)

Switch off the battery rack breaker, DC isolator, and AC input before handling RJ45 plugs on Hybrid Inverter LiFePO4 BMS. Powered down, measure DC resistance across Pins 4 (CAN-H) and 5 (CAN-L)—a healthy terminated bus reads ~60Ω (two 120Ω resistors in parallel), while 120Ω indicates one missing end resistor.

Farhan Ahamed
WRITTEN & AUDITED BY

Farhan Ahamed

Founder & Lead Protocol Architect • BMSBridge.online

Hardware diagnostics engineer specializing in 500 kbps CAN-Bus telemetry (0x351–0x35E), RJ45 VE.Can crossovers, and cell-safe 15S/16S LiFePO4 battery interoperability.