Closed-Loop or Open-Loop: Which One Keeps the House Running?
IN THIS GUIDE · QUICK JUMP KEY SECTIONS
01 · KEY SECTION Jump ↓

The night the link died

It was a new build, and it looked right. The SPF 5000 ES sat…

02 · KEY SECTION Jump ↓

What each mode gives you

Closed loop gives the inverter three things open loop cannot give it. First, live…

03 · KEY SECTION Jump ↓

The volts: 16S and 15S, kept apart

A 16S pack and a 15S pack do not share the same volts. Mixing…

04 · KEY SECTION Jump ↓

Why voltage-only charging works — and where it goes wrong

Voltage-only charging works because a LiFePO4 pack has a firm top. Push it to…

05 · KEY SECTION Jump ↓

Switch to open-loop in nine steps

Work the steps in order. If a check fails, stop there. Do the switch…

06 · KEY SECTION Jump ↓

If the reading differs, the reading is the answer

After the switch, the screen and the BMS app will disagree. That is normal.…

07 · KEY SECTION Jump ↓

What each symptom points to

Step-by-step field verification & diagnostic reference inside this section.

08 · KEY SECTION Jump ↓

Error 20, W000, and Warning 04: three codes, three faults

Do not mix up code families. Error 20 on the Growatt SPF off-grid range…

09 · KEY SECTION Jump ↓

What can still go wrong

Step-by-step field verification & diagnostic reference inside this section.

10 · KEY SECTION Jump ↓

Common questions

Step-by-step field verification & diagnostic reference inside this section.

11 · KEY SECTION Jump ↓

Do this next

Step-by-step field verification & diagnostic reference inside this section.

12 · KEY SECTION Jump ↓

Sources

Checked on 20 November 2026. Unconfirmed items are labelled “not confirmed” in the text.

What this guide works from. One rig: a Growatt SPF 5000 ES, a JK Inverter BMS, a 16-cell LiFePO4 pack, 280 Ah. The pack rests at 52.8 V. The JK app shows 47% charge. Error 20 shows on boot at 7 p.m.

The short answer. Closed-loop is safer when it works. Open-loop is safer than a broken closed-loop. Closed-loop means the BMS talks to the inverter over CAN or RS485. The inverter follows live data: state of charge, charge limits, and alarm flags. Open-loop means the inverter charges by volts alone. The BMS guards the pack in silence. On our rig, the link would not hold, so we switched to open-loop that night. Program 05 to USE, bulk 55.2 V, float 53.6 V, cut-off 48.0 V. The house kept its power, and the pack charged to full the next morning.

The night the link died

It was a new build, and it looked right. The SPF 5000 ES sat on the wall, and the battery box held 16 LiFePO4 cells. A JK Inverter BMS sat on top of the pack. The pack read 52.8 V: 3.30 V per cell, times 16 cells. The JK app showed all 16 cells between 3.29 V and 3.31 V, and 47% charge. Then the inverter was switched on, and Error 20 showed within seconds. The small Li icon flashed on and off, and no state of charge showed. The inverter still saw 52.8 V on the DC cables, but it had no data: no SOC, no charge limit, no cell temps. Without data, the inverter will not trust the battery.

We worked the cable and the menu first. The plug was in the CAN port, Program 36 read L52, and the bus read about 60 ohms with power off. The link still would not hold. It was 7 p.m., and the house needed power. So we switched to open loop that night.

The next morning told us the switch worked. Solar came up at 7 a.m. At 10:40 a.m. the pack hit 55.2 V, and the charge current tapered from 60 A down to 8 A. At 11:30 a.m. the inverter dropped to float at 53.6 V. The JK app showed all 16 cells between 3.44 V and 3.46 V at the top, and 100% charge. That evening the house ran on battery. At 9:15 p.m. the pack fell to 49.6 V and the inverter moved the loads to grid. The BMS app showed 22% charge at that point. The inverter screen showed 31%. The screen was guessing from volts. The app was counting amps. We trusted the app.

What each mode gives you

Closed loop gives the inverter three things open loop cannot give it. First, live SOC. The BMS counts amp hours in and out. It resets its count to 100% when the pack hits full charge and the current tapers. The inverter shows that number. It can plan charge and discharge around it.

Second, live limits. As the pack fills, the BMS drops its charge current limit. The inverter follows that limit and slows down before a cell trips. As the pack drains, the BMS drops its discharge limit. The inverter follows that limit too. Open loop cannot do that. It charges at a fixed current until the volts hit the bulk setting. It has no way to know a cell is running ahead until the BMS cuts.

Third, live alarms. A cell over-volt, a cell under-volt, a heat alarm, or a BMS guard state reaches the inverter with the SOC. The inverter can stop charging before the BMS has to cut. That is the safety margin closed loop buys you.

Closed loop also has a cost. It needs a cable, a code, a menu setting, and a DIP switch, all right at the same time. A wrong pin, a wrong code, or a wrong CAN speed breaks the link. Then the inverter may stop or warn even though the pack is fine. That is why a broken closed loop can be less safe than a working open loop. The inverter waits for data that never comes. It may cut output when the house needs it most. On a Growatt SPF in LI mode, there is one more cost to know. The inverter locks the max charge current. You cannot change it in the menus. The low cut-off and restart points switch to percent. The stock cut-off is 20%. If comms fail, the inverter cuts output and shows fault 20.

ModeWhat the inverter followsSOC sourceBest forMain risk
Closed loop CANBMS live limits, SOC, alarms.BMS amp hour count.JK, Pylontech, Seplos packs with a matching code.One wrong pin, code, or speed breaks the link.
Closed loop RS485BMS live limits, SOC, alarms, polled.BMS amp hour count.Packs with no CAN port, older inverters.Baud rate and A/B order add two more things to get wrong.
Open loop voltageFixed volts you set in the menus.Inverter volt guess, or BMS app / shunt.No comms port, unmatched code, need power tonight.Volt SOC is wrong on the flat curve, no live limits.
Bridge, Solar Assistant / YamBMSBMS data changed to a code the inverter reads.BMS via the bridge, plus shunt if fitted.JK-B boards, mixed packs, inverters with no native JK code.Bridge is one more box to power, update, and test.

Open loop gives you one thing closed loop cannot: freedom. The inverter does not wait for the BMS. It charges by volts and cuts by volts. It keeps the house running even if the comms cable fails or the BMS is a brand the inverter has never heard of. The cost is SOC, and it is a real cost. A LiFePO4 pack can sit at 52.0 V for hours, then fall fast once it leaves the flat part. Under load, the volts sag. A pack at 60% can read like a pack at 30% while a kettle runs. Under charge, the volts rise. A pack at 60% can read like a pack at 90% while solar pushes 40 A into it.

The volts: 16S and 15S, kept apart

A 16S pack and a 15S pack do not share the same volts. Mixing them up is the most common open-loop slip. A 16S pack is 51.2 V nominal, made from 3.2 V cells. A 15S pack is 48 V nominal. Pylontech packs are 15S. Most home packs are 16S. Write the cell count down from the nameplate or manual.

For 16S, use 55.2 V bulk, 53.6 V float, and 48.0 V low cut-off. That is 3.45 V, 3.35 V, and 3.00 V per cell. For 15S, use 51.75 V bulk, 50.25 V float, and 45.0 V cut-off. That is the same per-cell numbers. Only the pack maths changes. Turn equalization off. Set temperature compensation to 0 mV per degree C. Keep the charge current at 0.3C or below for daily solar charging unless your battery manual says otherwise in plain words. 0.3C means 30 A per 100 Ah. That is 60 A per 200 Ah, 84 A per 280 Ah.

SettingPer cell16S pack (51.2 V nominal)15S pack (48.0 V nominal)
Bulk / absorption3.45 V55.2 V51.75 V
Float3.35 V53.6 V50.25 V
Inverter low cut-off3.00 V48.0 V45.0 V
Back to utility3.10 V49.6 V46.5 V
Back to battery3.30 V52.8 V49.5 V
BMS under-volt cut2.80–2.90 V44.8–46.4 V42.0–43.5 V

Some guides on the web use higher volts, like 56.0 to 57.6 V bulk for 16S. We stay at 55.2 V on purpose. A higher bulk volt pushes cells closer to the BMS over-volt trip. At 55.2 V the pack reaches the top of the knee, and the balancer can work there.

Why voltage-only charging works — and where it goes wrong

Voltage-only charging works because a LiFePO4 pack has a firm top. Push it to 55.2 V for 16S and hold it there, and the cells fill. The current tapers as the pack fills, because the gap between the charge volt and the cell volt shrinks. The inverter does not need to know the SOC to do this. It only needs to hold the volt and watch the current fall.

It goes wrong in three places. First, the flat curve. From about 20% to 80% charge, a cell sits near 3.26 V to 3.32 V at rest. That is a spread of about 0.06 V per cell across 60% of the pack. For a 16S pack, that is about 1 V from 80% down to 20%. An inverter under load cannot read that cleanly. So the SOC on the screen is a guess, and the guess gets worse under load and under charge. A pack at 60% can read like 30% while a kettle runs. It can read like 90% while solar pushes 40 A in.

Second, SOC drift. A BMS counts amp hours in and out. That count drifts over weeks if the pack never hits full charge. When the pack hits 55.2 V for 16S and the current tapers, the BMS can reset its count to 100%. That reset is the anchor. After a month of half charges, the count can show 40% when the pack is near empty. So run a full charge weekly. Once a month is the least you should do.

Third, no live limits. In open loop the inverter charges at the current you typed until the volts hit bulk. It cannot slow down for a hot cell or a runner cell. The BMS is the only guard, and it guards by cutting power, not by asking the inverter to slow down. That is why the cut-off ladder matters. The inverter must close the first door, well above the BMS cut. Set the inverter cut-off to 48.0 V for 16S. Keep the BMS cut at 44.8 to 46.4 V. The gap is your warning time.

Switch to open-loop in nine steps

Work the steps in order. If a check fails, stop there. Do the switch at idle, with light loads.

  1. Write down what you have. Note the inverter model, battery and BMS brands, the cell count, and the code that drove the switch. Photograph Programs 05 and 36. Check: model names, cell count, and photos in hand.
  2. Cut the power before you touch a menu. Switch the battery breaker and AC breaker off. Wait until the LCD is dark. Check: LCD dark, battery breaker off.
  3. Set Program 05 to USE. Hold ENTER for three seconds, step to Program 05, and pick USE. US2 is User-Defined 2, the manual’s pick for lithium with no data link. Pick USE when you want bulk and float to differ. Pick US2 when you want one volt for both. Check: Program 05 reads USE, or US2.
  4. Set Program 19, the bulk volt. For a 16S pack, set it to 55.2 V. For a 15S pack, set it to 51.75 V. If Program 05 is US2, set Program 20 to the same volt. Check: Program 19 reads your bulk volt.
  5. Set Program 20, the float volt. For a 16S pack, set it to 53.6 V. For a 15S pack, set it to 50.25 V. Never set float above bulk. Check: Program 20 reads your float volt.
  6. Set the cut-offs. Set Program 21, the low DC cut-off, to 48.0 V for 16S or 45.0 V for 15S. Set Program 12, back to utility, to 49.6 V for 16S or 46.5 V for 15S. Set Program 13, back to battery, to 52.8 V for 16S or 49.5 V for 15S. Check: Program 21 reads your cut-off volt.
  7. Set the current and turn off the lead-acid stages. Set Program 02, the max charge current, to 0.3C or below: 84 A on a 280 Ah pack. Turn equalization off. Set temperature compensation to 0 mV per degree C. Check: current at or below 0.3C, equalization off, temp comp 0.
  8. Power up and watch one full charge. Switch the battery on first, then the inverter. Watch the pack climb to bulk, hold 30 to 60 minutes, then drop to float. On our rig, the pack hit 55.2 V at 10:40 a.m., the current tapered from 60 A to 8 A, and float came at 11:30 a.m. Check the cell spread at the top in the BMS app. Check: pack reaches bulk, current tapers, float follows, cells within 0.10 V.
  9. Watch one discharge, then write it down. Run the house on battery until the pack falls toward the back-to-utility volt. The inverter should move loads to grid at 49.6 V for 16S and stop drawing at 48.0 V. The BMS should not cut. Write the cell count, the mode, and all the numbers on a card near the inverter. Check: grid switch at 49.6 V, no BMS cut, card written.

If the reading differs, the reading is the answer

After the switch, the screen and the BMS app will disagree. That is normal. The screen guesses from volts. The app counts amps. Trust the app. Use the inverter volts for cut-offs, not for SOC.

ReadingWhat it means.What to do.
Screen SOC and app SOC match, both move.Link alive, closed-loop.Stay in closed-loop.
Screen SOC frozen, app SOC moves.Link dead, inverter guessing.Switch to open-loop tonight, fix the link in daylight.
Pack hits 55.2 V, current tapers to near zero.Pack full, balancer working.Let it drop to float.
One cell more than 0.10 V ahead at the top.Pack out of balance.Lower bulk to 54.4 V for 16S, balance the pack.
BMS cuts before the inverter cut-off.Inverter cut-off too low.Raise the inverter cut-off by 0.8 V.

What each symptom points to

What you see.Most likely cause.Fix.
Error 20 on boot, flashing Li icon, no SOC.Link fault: cable, port, or protocol code.Fix the link, or switch to USE tonight.
Inverter cuts at night, screen read 60%.Volt SOC lied under load.Use the BMS app for SOC. Raise the cut-off if the BMS cuts first.
Pack never reaches 55.2 V.Runner cell, or charge current too high.Check the cell spread, lower bulk to 54.4 V.
BMS cuts first, loads drop.Inverter cut-off too low.Raise the inverter cut-off by 0.8 V.
SOC drifts after weeks of part charge.No full-charge reset.Run a full charge weekly.

Error 20, W000, and Warning 04: three codes, three faults

Do not mix up code families. Error 20 on the Growatt SPF off-grid range is a BMS fault. The inverter cannot hear the battery BMS. On EG4 and Luxpower inverters, the comms failure code is W000, not Error 19. Fault 19 on an EG4 is bus voltage too high, a different fault with a different cause. On Growatt, Warning 04 means low battery, and the SPF 3500 ES manual says it is often caused by a link fault on lithium: fix the link fault first. Together they point to the same root cause. Charge first if you can, then fix the link. The full Error 20 checklist is in the Growatt Error 20 fix.

What can still go wrong

Some inverters will not run with no link.

Before you plan an open-loop setup, check the manual first. Ask the seller: does this inverter run with no battery comms? If the answer is no, open-loop is not an option for that box. You need a working link or a different inverter.

A bridge is a third option.

Solar Assistant, YamBMS, and the Sleeper85 esphome-jk-bms-can project read a BMS that the inverter cannot read. They send the data to the inverter in a protocol it does understand, often Pylontech CAN. A JK-B board with no CAN port can talk to a Deye through an ESP32 bridge. A mixed bank of JK and Pylontech packs can talk to one inverter through a bridge that sums the data into one stream. A bridge is not free. It is one more box to power, one more cable to test, and one more firmware to update. Test it the same way you test a direct link. Compare SOC on both screens for five minutes. Watch the charge taper near full.

Set the same volts on every charge source.

Your MPPT, your grid charger, and your inverter should all use the same bulk, float, and cut-off numbers.

Common questions

Is open-loop safe?

Yes, when the volts are right and the BMS is healthy. The BMS still guards every cell. It cuts charge on a high cell and cuts discharge on a low cell. What you lose is early warning: the inverter cannot slow down before the BMS cuts.

Will my BMS still protect the pack in open-loop?

Yes. The BMS guards the pack by itself. It does not need the inverter to do that job. It cuts the pack if a cell goes out of range. What it cannot do in open-loop is tell the inverter to slow down first. That is why the inverter cut-off sits well above the BMS cut.

Why does the SOC on the screen lie?

Because the screen guesses SOC from volts, and the LiFePO4 curve is flat in the middle. A pack at 60% can read like 30% under load and like 90% under charge. Use the BMS app or a shunt for a true SOC number.

Can I go back to closed-loop later?

Yes. When you have a working cable, the right protocol, and a BMS the inverter lists as supported, set Program 05 back to LI and Program 36 to the protocol code for your battery. L52 is Pylontech CAN on the SPF 5000 ES. Follow the pairing guide for that exact BMS and inverter. Keep the open-loop numbers written down. You may need them again.

Do I need a shunt?

Not to run open loop, but it helps. A Victron SmartShunt sits on the battery negative wire and counts current in both directions. It gives a true SOC number when the inverter screen cannot. If you run open loop for months, a shunt is worth the cost.

Do this next

  1. Ask three questions: does the BMS have a CAN or RS485 port the inverter can read? Does the inverter list a code for that battery, or for Pylontech as a stand-in? Does the link hold for a full charge cycle, not just five minutes at idle? If the answer to all three is yes, run closed loop. If the answer to any one is no, run open loop tonight, and fix the link in daylight.
  2. Check the cell count from the nameplate, 15S or 16S. Set the volts from the table for your cell count.
  3. Switch at idle with light loads. Set Program 05 to USE, Programs 19, 20, and 21 to bulk, float, and cut-off, and Program 02 to 0.3C or below.
  4. Watch one full charge and one discharge. The BMS should not cut. If it cuts first, raise the inverter cut-off by 0.8 V.
  5. Write the final numbers on a card near the inverter, with the date and the cell count.
  6. Test the comms-loss case on purpose at setup: pull the comms cable out and watch what the inverter does.

Sources

Checked on 20 November 2026. Unconfirmed items are labelled “not confirmed” in the text.

QUESTIONS ANSWERED

Operator Questions Answered (Playbook FAQ)

Switch off the battery rack breaker, DC isolator, and AC input before handling RJ45 plugs on Hybrid Inverter LiFePO4 BMS. Powered down, measure DC resistance across Pins 4 (CAN-H) and 5 (CAN-L)—a healthy terminated bus reads ~60Ω (two 120Ω resistors in parallel), while 120Ω indicates one missing end resistor.

Farhan Ahamed
WRITTEN & AUDITED BY

Farhan Ahamed

Founder & Lead Protocol Architect • BMSBridge.online

Hardware diagnostics engineer specializing in 500 kbps CAN-Bus telemetry (0x351–0x35E), RJ45 VE.Can crossovers, and cell-safe 15S/16S LiFePO4 battery interoperability.