Closed-Loop vs. Open-Loop Tuning ✓ BENCH VERIFIED UPDATED NOVEMBER 21, 2026 15 MIN READ 3,275 WORDS

My Solis Lost the BMS Link — Is User-Define Mode Safe?

Farhan Ahamed
Farhan Ahamed Published November 19, 2026 · 15 min read
0 COMMENTS
My Solis Lost the BMS Link — Is User-Define Mode Safe?
IN THIS GUIDE · QUICK JUMP KEY SECTIONS
01 · KEY SECTION Jump ↓

The rig that lost its link at noon

It was a working build until one hot day. The Solis S6-EH1P5K-L sat on…

02 · KEY SECTION Jump ↓

What User-Define actually does

A Solis hybrid in normal lithium mode is a closed-loop machine. Closed-loop means the…

03 · KEY SECTION Jump ↓

When to switch: CAN Fail, BATName-Fail, and the BMS alarms

Do not switch modes on a guess. Match the alarm first. Three Solis alarms…

04 · KEY SECTION Jump ↓

The settings: 16S and 15S, kept apart

A pack sold as “48 V” can be 15S or 16S. Pylontech US2000, US3000…

05 · KEY SECTION Jump ↓

Check the CAN cable first — do not switch before checking

Most CAN Fail alarms are cable faults, not dead links, and a mode change…

06 · KEY SECTION Jump ↓

How to switch, step by step

Do this at idle, with light loads, not in the middle of a heavy…

07 · KEY SECTION Jump ↓

After the switch: what to watch

The SOC on the inverter screen will move, but it is a volts guess…

08 · KEY SECTION Jump ↓

If the reading differs, the reading is the answer

The first charge after the switch tells you if the volts are right. Read…

09 · KEY SECTION Jump ↓

Switching back to closed-loop

User-Define is a fallback, not a fixed home. When the cable is fixed, switch…

10 · KEY SECTION Jump ↓

What can still go wrong

Step-by-step field verification & diagnostic reference inside this section.

11 · KEY SECTION Jump ↓

Common questions

Step-by-step field verification & diagnostic reference inside this section.

12 · KEY SECTION Jump ↓

Do this next

Step-by-step field verification & diagnostic reference inside this section.

What this guide works from. One rig: a Solis S6-EH1P5K-L hybrid, a 16-cell LiFePO4 pack, 280 Ah, with a JK Inverter BMS, resting at 52.8 V, JK app showing 61% charge. The inverter shows CAN Fail, alarm 2012, and the link will not come back.

The short answer. Yes, User-Define mode is safe here, if you set the volts right. BMS means battery management system, the small board in the battery that guards the cells. Set the battery model to User-Define in Advanced Settings, under Storage Energy Set and Battery Select. The password is 0010. The inverter stops asking the BMS for data and charges by the volts you type in instead. For a 16S LiFePO4 pack, use bulk 55.2 V, float 53.6 V and a low cut-off of 48.0 V. 16S means 16 cells in a row. For a 15S pack, use 51.75 V, 50.25 V and 45.0 V. Check the CAN cable first. A loose plug is a faster fix than a mode change. Once the link is truly dead, User-Define is the right call, not a hack.

The rig that lost its link at noon

It was a working build until one hot day. The Solis S6-EH1P5K-L sat on the wall. The battery box held 16 LiFePO4 cells with a JK Inverter BMS. The pack read 52.8 V at rest: 3.30 V per cell, times 16 cells. The JK app showed 61% charge. The house ran on solar by day and battery by night. Then, at noon, the inverter threw CAN Fail, alarm 2012. The battery icon went grey. The SOC froze at 61%. The inverter kept running, but on volts alone. The owner checked the plug. It clicked home. The owner power-cycled the battery. The alarm stayed. The owner power-cycled the inverter. The alarm stayed. The link was dead. User-Define mode was the way to keep the house running that night.

What User-Define actually does

A Solis hybrid in normal lithium mode is a closed-loop machine. Closed-loop means the inverter reads live data from the BMS. It reads the battery model you picked in Battery Select, talks to the BMS over CAN, and follows the charge limits, SOC and alarm flags the BMS sends. SOC means state of charge, how full the battery is in percent. When that link works, it is the safest way to run the system, because the BMS can tell the inverter to slow down.

In User-Define mode, the inverter no longer waits for BMS data. It charges by the volts you type in. It drains by the cut-off you type in. You set the charge volts. You set the current limits. You set the over-discharge point. You set the recovery point. You set the force-charge point. The BMS still guards the pack. It still cuts charge if a cell goes too high. It still cuts discharge if a cell goes too low. But the inverter does not know about it until the BMS acts.

This mode is on the Solis RHI single-phase hybrids, the RHI-1P 5K to 10K HVES-5G series, the RHI-3P three-phase series, and the S6-EH1P single-phase hybrids. The menu names shift a bit between them. If a field on your screen is named different, match it by what it means, not by how it is spelled.

One limit first: User-Define only works on 48 V low-volt Solis models, like the RHI and S6-EH1P lines. High-volt Solis inverters are CAN-only, with no volts mode. If yours is a high-volt unit, fix the CAN link instead. One more caution from Solis support: do not take User-Define to mean any unlisted battery is now fine. Use it only when the battery maker and the Solis docs back the manual settings. It is a fallback for a known pack with a dead link, not a way to force a random battery onto the inverter.

When to switch: CAN Fail, BATName-Fail, and the BMS alarms

Do not switch modes on a guess. Match the alarm first. Three Solis alarms look alike, and only one means the link is dead. The table below splits them. Read the row that matches your screen. Only one row ends in User-Define. The other rows end in a fix that keeps closed-loop. Check the table before you touch a menu.

Alarm on the screenWhat it meansFirst fix
CAN Fail 2012, CAN_Comm_FAILCAN talk between inverter and battery is lostCheck the CAN cable and the battery power
BAT_Comm-FAILNo talk, or the wrong battery pickedCheck the wire, then the Battery Select entry
BatName-FAIL 2016Wrong pick of battery brandPick the nameplate model in Battery Select
Alarm1-BMS 2015, Alarm2-BMS 2017The battery’s own BMS raised an alarmRestart the battery; the fault sits with the battery
NO-Battery 1055The battery is not plugged inCheck the breaker, the fuse, and the battery switch

CAN Fail, alarm 2012. This is the lost-link alarm. The S6-EH1P5K-L-PLUS manual’s FAQ asks why this alarm shows. It answers: CAN Fail means the CAN talk between inverter and battery is lost. Check that the CAN cable is plugged in right and that the battery is on. If the cable is good, the battery is on, and CAN Fail stays, the link is dead and User-Define is the move. On our rig, this was the alarm. The cable was good. The alarm stayed. So we switched.

BAT_Comm-FAIL. No talk between the inverter and battery, or the wrong battery picked. Check the RS485 or CAN wire first. Then check that the right battery is picked in Battery Select. This one is often a settings slip, not a dead link.

BatName-FAIL, alarm 2016. Wrong pick of battery brand. The manual’s FAQ asks why this alarm shows. It answers: check Battery Setting and Battery Model. Pick the right battery option as the nameplate of your battery module. The nameplate is the label on the battery. Fix the pick first. User-Define is the wrong answer to a wrong brand pick. Here is why DIY packs hit this alarm so often. The inverter looks for a PYLON name tag in the CAN data. It looks at CAN ID 0x35E, in the first two bytes. A JK BMS does not send that tag. So the inverter sees live data but no name. Then it throws BatName-FAIL. Picking User-Define clears it. The inverter stops asking for the tag at all.

Alarm1-BMS and Alarm2-BMS, 2015 and 2017. The battery’s own BMS raised an alarm. Restart the battery. If the alarm stays, the fault sits with the battery. Switching to User-Define will not fix it. A BMS that has cut discharge to guard a cell will not come back just because the inverter stopped asking. Note: “CAN Fail 2015” could not be confirmed as a Solis code. 2015 is a BMS alarm, not a CAN Fail code.

NO-Battery, 1055. The battery is not plugged in. Check the battery breaker or fuse, and check the battery is switched on. This is a DC wiring fault, not a comms fault.

On first start, a CAN FAIL error may show, and that is normal. The battery protocol has not been set yet. Go to Advanced Settings, Storage Energy Set, Battery Select, and pick your battery model. Then the talk starts. If you switch to User-Define the first time you see CAN Fail on a new install, you will never know if closed-loop would have worked.

The settings: 16S and 15S, kept apart

A pack sold as “48 V” can be 15S or 16S. Pylontech US2000, US3000 and US5000 packs are 15S, while most DIY server-rack packs are 16S. Check the cell count from the nameplate or manual, then pick the column. The table below is the whole settings set. Each row is one setting. Do not mix the columns. A 16S pack set to 15S volts will never reach full. A 15S pack set to 16S volts will overcharge.

SettingPer cell16S pack (51.2 V nominal)15S pack (48.0 V nominal)
Bulk / absorption3.45 V55.2 V51.75 V
Float3.35 V53.6 V50.25 V
Low cut-off3.00 V48.0 V45.0 V
Back to utility3.10 V49.6 V46.5 V
BMS under-volt cut2.80–2.90 V44.8–46.4 V42.0–43.5 V
Absolute cell max3.65 V58.4 V54.75 V

Set the charge current to 0.3C or less: 30 A per 100 Ah, 60 A per 200 Ah, 84 A per 280 Ah. 0.3C means three tenths of the pack size in amps. Turn equalization off, and set temp comp to 0 mV/°C. Temp comp means the inverter shifts volts with heat. LiFePO4 does not need that shift. A 16S pack at 55.2 V bulk reaches the top of the charge knee, where the balancer can work. The cells settle back to about 3.40 V per cell at rest, or 54.4 V for the pack. That is full.

The Solis SOC settings still matter in User-Define mode, and they have an order rule. Force charge SOC must be below over-discharge SOC. Over-discharge SOC must be below recovery SOC. If not, the setting will error. The S6 manual gives the ranges. Over-discharge SOC runs from 5% to 40%, with a default of 20%. Recovery SOC runs from the over-discharge value plus 1% to plus 20%. Force charge SOC is the point where the inverter force-charges the battery from the grid. Max charge SOC defaults to 100%. Set over-discharge to 20% as a start. Set recovery to 30%. Set force charge to 10%. In User-Define mode the inverter’s SOC is a volts guess, not a BMS count.

Check the CAN cable first — do not switch before checking

Most CAN Fail alarms are cable faults, not dead links, and a mode change will not fix a cable. Before you switch, work this short list. The CAN cable is in the CAN port on both ends, and it is the right cable. Some batteries need a special cable from the battery maker. A straight Ethernet cable is not it. The battery is on. The plug clicks home at both ends.

The Solis CAN port puts CAN-H on pin 4 and CAN-L on pin 5, the same as Deye and Growatt. That map comes from the WeCo installer guide for Solis hybrids. The battery side is CAN-H pin 1 and CAN-L pin 2, with the cable changed on site to match. Count pins with the clip facing away from you, pin 1 on the left. If your battery manual prints a different pinout, follow the battery manual.

Check the 60 ohm end test too. Power both units off, unplug the CAN cable from one end, and measure CAN-H to CAN-L. About 60 ohm means both ends are closed off right. About 120 ohm means one end is missing. Open circuit means no end resistor or a broken wire. Then power the BMS first, then the inverter, and watch the CAN Fail alarm clear. If it clears, closed-loop was never dead. On our rig, the test read 61 ohms. The cable was good. The alarm stayed. So we switched.

How to switch, step by step

Do this at idle, with light loads, not in the middle of a heavy drain. Write down the current settings first.

  1. Check the cell count. Check the cell count from the nameplate or manual. Write down 15S or 16S. Check: the count is written down.
  2. Switch to User-Define. Go to Advanced Settings (password 0010), then Storage Energy Set, then Battery Select. Change the battery model to User-Define. Check: the screen reads User-Define.
  3. Set the battery type. Set the battery type to the volts-based option if the menu asks for one. Check: the type reads as the volts option.
  4. Set bulk, float, and cut-off. For 16S, set bulk to 55.2 V. Set float to 53.6 V. Set the low cut-off to 48.0 V. For 15S, set 51.75 V, 50.25 V and 45.0 V. Check: the three volts match the table column for your cell count.
  5. Set current and turn-offs. Set max charge and discharge current to 0.3C or less. Turn equalization off. Set temp comp to 0 mV/°C. Check: current is 0.3C or less. Equalization is off. Temp comp reads 0.
  6. Set the SOC points in order. Set over-discharge to 20%. Set recovery to 30%. Set force charge to 10%. Keep the order rule. Force charge stays below over-discharge. Over-discharge stays below recovery. Check: 10% is below 20%. 20% is below 30%.
  7. Set the back-to-utility volts. For 16S, set back-to-utility to 49.6 V. Set back-to-battery to 52.8 V. For 15S, set 46.5 V and 49.5 V. Check: the volts match the table for your cell count.
  8. Charge on a sunny morning. Save the settings. Then charge on a sunny morning. Watch the pack reach bulk. It should hold 30 to 60 minutes. Then it should drop to float. Check the cell spread at the top in the BMS app. Cell spread is the gap between the highest and lowest cell. If one cell runs more than 0.10 V ahead, lower bulk to 54.4 V. Check: the pack holds bulk 30 to 60 minutes. Then it drops to float.
  9. Watch one drain. The inverter should switch to grid at the back-to-utility volts. It should stop drawing at the cut-off. The BMS should not cut. If it cuts first, raise the cut-off by 0.8 V. Check: the inverter stops drawing at the cut-off. The BMS does not cut.
  10. Write the numbers on a card. Write the final numbers on a card near the inverter, with the date and the cell count. Check: the card is on the wall.

After the switch: what to watch

The SOC on the inverter screen will move, but it is a volts guess now, so check it against the BMS app. On our rig, the inverter said 55% at dusk while the JK app said 61%. The BMS was right. The gap is normal in User-Define mode. It is not a fault. Trust the BMS app for SOC.

A cell that keeps running ahead is a balance fault, not a settings fault, and no volt number will fix it. If one cell runs more than 0.10 V ahead at the top of the charge, week after week, the pack needs a balance session or a cell check. Lowering bulk to 54.4 V buys time.

Use the Solis battery wake-up if the pack goes to sleep. The S6 manual tells of a Battery Wakeup switch. After the wake-up command, the inverter powers the DC battery port with the wake-up volts and low current until BMS talk returns. Auto Bat Awaken fires the wake-up each morning. In User-Define mode the wake-up still matters. A sleeping BMS will not guard the pack while the inverter charges by volts alone.

If the reading differs, the reading is the answer

The first charge after the switch tells you if the volts are right. Read the row that matches what you see. Each row names the cause. Each row gives the fix. Change one setting at a time. Give each change a full charge cycle to show. A volt change that looks wrong at noon can look right at dusk. Judge it over a full cycle, not over one hour.

What you see after the switchMost likely causeFix
Pack never reaches bulkBulk set too high for the charger, or a cell runs aheadCheck the cell spread; lower bulk to 54.4 V
Pack hits bulk, then drops fastCharge current too high for the pack sizeCut the current to 0.3C or less
Inverter cuts out while the BMS app shows 40%Cut-off set too high, or volts sag under loadRaise the cut-off by 0.8 V at a time
BMS cuts first on a drainInverter cut-off set below the BMS cutRaise the inverter cut-off by 0.8 V
SOC on the inverter jumps aroundVolts guess on the flat curveTrust the BMS app for SOC
CAN Fail clears after a power cycleCable or port fault, not a dead linkSwitch back to closed-loop

On our rig, the first charge hit bulk at 55.2 V by 11 in the morning. It held 45 minutes, then dropped to float at 53.6 V. The cell spread at the top was 0.04 V. The drain that night switched to grid at 49.6 V and stopped drawing at 48.0 V. The BMS did not cut.

Switching back to closed-loop

User-Define is a fallback, not a fixed home. When the cable is fixed, switch back. When the protocol is fixed, switch back. When the battery is fixed, switch back. Go to Advanced Settings. Then Storage Energy Set. Then Battery Select. Pick your battery model again. Pick the nameplate model, not a near match. Give it five minutes. Then check SOC on both screens. If they agree within a few percent, closed-loop is back. The charge should slow near full. Keep the User-Define numbers written down. A card by the inverter beats a search through old notes at midnight.

What can still go wrong

The wrong column.

A 16S pack set to 15S volts will never reach full. A 15S pack set to 16S volts will overcharge. Check the cell count on the nameplate first. Do not guess from the “48 V” label.

The SOC order error.

Force charge must be below over-discharge, which must be below recovery. If the setting errors, check the order first. Set 10%, 20%, 30% and work from there.

The sleeping BMS.

A sleeping BMS will not guard the pack while the inverter charges by volts alone. Use the Battery Wakeup switch. Turn on Auto Bat Awaken so it fires each morning.

The high-volt trap.

User-Define does not exist on high-volt Solis inverters. They are CAN-only. If yours is a high-volt unit, do not hunt for a volts menu. Fix the CAN link instead.

The BMS alarm trap.

If the BMS raised an alarm, User-Define will not fix it. Restart the battery first.

Common questions

Is User-Define mode safe for a LiFePO4 pack?

Yes, if the volts are right. Use 55.2 V bulk, 53.6 V float, and 48.0 V cut-off for 16S. The BMS still guards the pack. It still cuts charge or discharge if a cell goes out of range.

Should I check the CAN cable before I switch?

Yes, always. Most CAN Fail alarms are cable faults. Check the plug, the port, and the 60 ohm test first. If the alarm clears, closed-loop was never dead.

Why does the inverter SOC disagree with the BMS app now?

The inverter SOC is a volts guess in User-Define mode. The BMS app counts amps. Trust the BMS app for SOC.

Can I switch back to closed-loop later?

Yes. Pick your battery model again in Battery Select. Give it five minutes. If the SOC numbers agree within a few percent, closed-loop is back.

Do this next

  1. Check the CAN cable and port before you touch a menu. Run the 60 ohm test.
  2. If CAN Fail stays after a good cable and power cycle, switch to User-Define.
  3. Battery Select, User-Define, then bulk 55.2 V, float 53.6 V, cut-off 48.0 V for 16S, or 51.75 V, 50.25 V, 45.0 V for 15S.
  4. Set the current to 0.3C or less, equalization off, temp comp to 0 mV/°C, and the SOC points in order: 10%, 20%, 30%.
  5. Watch one full charge and one full drain. If the BMS cuts first, raise the cut-off by 0.8 V.
  6. Write the final numbers on a card near the inverter. Switch back to closed-loop when the link is fixed.

Sources

Checked on 20 November 2026. Unconfirmed items are labelled “not confirmed” in the text.

  • Solis S6-EH1P5K-L-PLUS manual, FAQ section. CAN Fail means the CAN talk between inverter and battery is lost. BATName-Fail means the wrong battery model is picked.
  • Solis S6 manual, Storage Energy Set section. Over-discharge SOC 5% to 40%, default 20%. Recovery SOC from over-discharge plus 1% to plus 20%. Battery Wakeup switch and Auto Bat Awaken.
  • Solis RHI and S6-EH1P manuals, Battery Select. User-Define mode on 48 V low-volt models. High-volt models are CAN-only.
  • WeCo installer guide for Solis hybrids. Solis CAN port: CAN-H pin 4, CAN-L pin 5.
  • Solis support note, via installer guides. Use User-Define only when the battery maker and the Solis docs back the manual settings.
  • ISO 11898-2 CAN standard. Two 120 ohm end resistors in parallel read about 60 ohms. 120 ohms means one end is missing. Open circuit means no end resistor or a broken wire.
  • This site: closed-loop vs open-loop LiFePO4 settings, open-loop LiFePO4 voltage settings, Growatt Error 20 fix, JK BMS to Deye setup.
QUESTIONS ANSWERED

Operator Questions Answered (Playbook FAQ)

Switch off the battery rack breaker, DC isolator, and AC input before handling RJ45 plugs on Hybrid Inverter LiFePO4 BMS. Powered down, measure DC resistance across Pins 4 (CAN-H) and 5 (CAN-L)—a healthy terminated bus reads ~60Ω (two 120Ω resistors in parallel), while 120Ω indicates one missing end resistor.

Farhan Ahamed
WRITTEN & AUDITED BY

Farhan Ahamed

Founder & Lead Protocol Architect • BMSBridge.online

Hardware diagnostics engineer specializing in 500 kbps CAN-Bus telemetry (0x351–0x35E), RJ45 VE.Can crossovers, and cell-safe 15S/16S LiFePO4 battery interoperability.